The effect of dilution medium on the measurement of in-vitro properties of ultrasound contrast agents

被引:0
|
作者
Lazewatsky, J [1 ]
Kagan, M [1 ]
Barrett, JA [1 ]
机构
[1] Dupont Pharmaceut Co, Med Imaging Discovery Res, N Billerica, MA 01862 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although clinical detection of ultrasound contrast agents requires injection of the agent into the human circulatory system, most in-vitro measurements have been made with agents diluted in aqueous media such as saline or Isoton(R). The differences between blood and saline have the potential to alter observed physical properties. We present a series of experiments to identify differences in in-vitro behavior of a contrast agent diluted in different media. In one set of experiments, Definity(TM), a suspension of lipid-encapsulated microbubbles of perfluoropropane, was exposed to ultrasound from a clinical ultrasound system. The agent was diluted in either blood or USP saline in a small test cell immersed in a water bath at either room temperature or 37 degrees C. The resulting B-mode images were digitized and the mean videointensity in a region within the cell as a function of time determined. The average videointensity and the mean integrated videointensity were used to compare the two conditions. In all cases, the duration of the videointensity was significantly greater for Definity(TM) in blood than in saline. The time for the signal to decay to one half the initial videointensity was 400 seconds for blood vs. 90 seconds for saline. The mean integral of the normalized videointensity over time was in all cases greater for Definity(TM) in blood than in saline. We concluded that Definity(TM) is significantly more stable to ultrasound exposure when it is diluted in blood than when diluted in saline. Further, the rate of disappearance of contrast agent in blood as well as in saline is related to the acoustic output of the ultrasound scanhead and to increases in the ambient pressure. The two factors were additive.
引用
收藏
页码:1737 / 1742
页数:6
相关论文
共 50 条
  • [31] Indicator Dilution Models for the Quantification of Microvascular Blood Flow With Bolus Administration of Ultrasound Contrast Agents
    Strouthos, Costas
    Lampaskis, Marios
    Sboros, Vassilis
    McNeilly, Alan
    Averkiou, Michalakis
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (06) : 1296 - 1310
  • [32] The Effect of Mixing Iodinated Contrast Media and Ultrasound Contrast Agents on Subharmonic Signals
    Esposito, Cara
    Tzan, Kenneth
    Machado, Priscilla
    Forsberg, Flemming
    Dave, Jaydev K.
    ULTRASONIC IMAGING, 2024, 46 (02) : 130 - 134
  • [33] Ultrasound contrast agents:: properties, principles of action, tolerance, and artifacts
    Correas, JM
    Bridal, L
    Lesavre, A
    Méjean, A
    Claudon, M
    Hélénon, O
    EUROPEAN RADIOLOGY, 2001, 11 (08) : 1316 - 1328
  • [34] Ultrasound contrast agents: properties, principles of action, tolerance, and artifacts
    Jean-Michel Correas
    Lori Bridal
    Amélie Lesavre
    Arnaud Méjean
    Michel Claudon
    Olivier Hélénon
    European Radiology, 2001, 11 : 1316 - 1328
  • [35] Effect of certain antimicrobial agents on in-vitro digestibility of nutrients
    Prakash, N
    Ramachandra, B
    Nagabhushan, V
    INDIAN VETERINARY JOURNAL, 2005, 82 (11): : 1171 - 1173
  • [36] THE EFFECT OF ANTISEBORRHOEIC AGENTS ON PITYROSPORUM-OVALE IN-VITRO
    NENOFF, P
    HAUSTEIN, UF
    HAUTARZT, 1994, 45 (07): : 464 - 467
  • [37] Effect of additives in medium on in-vitro maturation of goat oocytes
    Borah, D.
    Biswas, R. K.
    INDIAN JOURNAL OF ANIMAL RESEARCH, 2020, 54 (01) : 11 - 15
  • [38] EFFECT OF SOME CHEMICAL AGENTS ON RENIN ACTIVITY IN-VITRO
    REINHARZ, A
    ROTH, M
    HAEFELI, L
    SCHAECHTELIN, G
    ENZYME, 1971, 12 (02) : 212 - +
  • [39] Correlation analysis of received echoes from contrast agents in-vitro and in-vivo
    Chomas, JE
    Sikes, RA
    Ferrara, KW
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1803 - 1806
  • [40] Magnetic microparticles as labeling or contrast medium for medical imaging, an in-vitro feasibility study
    Takeuchi, Y.
    Proceedings of the IEEE Ultrasonics Symposium, 1998, 2 : 1807 - 1810