The effect of dilution medium on the measurement of in-vitro properties of ultrasound contrast agents

被引:0
|
作者
Lazewatsky, J [1 ]
Kagan, M [1 ]
Barrett, JA [1 ]
机构
[1] Dupont Pharmaceut Co, Med Imaging Discovery Res, N Billerica, MA 01862 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although clinical detection of ultrasound contrast agents requires injection of the agent into the human circulatory system, most in-vitro measurements have been made with agents diluted in aqueous media such as saline or Isoton(R). The differences between blood and saline have the potential to alter observed physical properties. We present a series of experiments to identify differences in in-vitro behavior of a contrast agent diluted in different media. In one set of experiments, Definity(TM), a suspension of lipid-encapsulated microbubbles of perfluoropropane, was exposed to ultrasound from a clinical ultrasound system. The agent was diluted in either blood or USP saline in a small test cell immersed in a water bath at either room temperature or 37 degrees C. The resulting B-mode images were digitized and the mean videointensity in a region within the cell as a function of time determined. The average videointensity and the mean integrated videointensity were used to compare the two conditions. In all cases, the duration of the videointensity was significantly greater for Definity(TM) in blood than in saline. The time for the signal to decay to one half the initial videointensity was 400 seconds for blood vs. 90 seconds for saline. The mean integral of the normalized videointensity over time was in all cases greater for Definity(TM) in blood than in saline. We concluded that Definity(TM) is significantly more stable to ultrasound exposure when it is diluted in blood than when diluted in saline. Further, the rate of disappearance of contrast agent in blood as well as in saline is related to the acoustic output of the ultrasound scanhead and to increases in the ambient pressure. The two factors were additive.
引用
收藏
页码:1737 / 1742
页数:6
相关论文
共 50 条
  • [21] Measurement of the attenuation coefficient for monodisperse populations of ultrasound contrast agents
    Gong, Yanjun
    Cabodi, Mario
    Porter, Tyrone M.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1964 - 1966
  • [22] ULTRASOUND PROPERTIES OF LIVER WITH AND WITHOUT PARTICULATE CONTRAST AGENTS
    TUTHILL, TA
    BAGGS, RB
    VIOLANTE, MR
    PARKER, KJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (03): : 231 - 237
  • [23] EFFECT OF ADRENERGIC AGENTS ON ANTIBODY RESPONSE IN-VITRO
    PEARLMAN, DS
    JOURNAL OF ALLERGY, 1971, 47 (02): : 109 - &
  • [24] THE EFFECT OF COLLOID DILUTION ON IN-VITRO CLOT DYNAMICS USING THROMBOELASTOGRAPHY
    SMITH, SN
    SHAH, MV
    MARTIN, P
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 29 - 29
  • [25] EFFECT OF ADRENERGIC AGENTS ON RENIN RELEASE IN-VITRO
    NOLLY, HL
    REID, IA
    GANONG, WF
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 253 - 253
  • [26] Acrylic based hydrogel phantom for in-vitro ultrasound contrast agent characterization
    Dernitri, C.
    Montagna, E.
    Sannino, A.
    Maffezzoli, A.
    VIRTUAL AND RAPID MANUFACTURING: ADVANCED RESEARCH IN VIRTUAL AND RAPID PROTOTYPING, 2008, : 295 - 298
  • [27] EFFECT OF A RADIOTHERAPEUTIC MEGAVOLTAGE BEAM ON ULTRASOUND CONTRAST AGENTS
    Collado-Lara, Gonzalo
    Heymans, Sophie V.
    Godart, Jeremy
    D'Agostino, Emiliano
    D'hooge, Jan
    Van Den Abeele, Koen
    Vos, Hendrik J.
    de Jong, Nico
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (07): : 1857 - 1867
  • [28] In vitro Evaluation of Ultrasound-Assisted Thrombolysis Using Targeted Ultrasound Contrast Agents
    Ruan, Jia-Ling
    Cheng, Po-Wen
    Chen, Suz-Chia
    Chuang, Yueh-Hsun
    Li, Pai-Chi
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1659 - +
  • [29] In vitro evaluation of acoustic properties of ultrasound contrast agents: Experimental set-up and signal processing
    Cachard, C
    Bouakkaz, A
    Gimenez, G
    ULTRASONICS, 1996, 34 (2-5) : 595 - 598
  • [30] A critical assessment of the in-vitro measurement of cortical bone stiffness with ultrasound
    Peralta, L.
    Cai, X.
    Laugier, P.
    Grimal, Q.
    ULTRASONICS, 2017, 80 : 119 - 126