Electrical impedance measurements of cochlear structures using the four-electrode reflection-coefficient technique

被引:9
|
作者
Kumar, Gagan [1 ]
Chokshi, Moulin [1 ]
Richter, Claus-Peter [1 ,2 ,3 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Otolaryngol Head & Neck Surg, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[3] Northwestern Univ, Dept Commun Sci & Disorders, Hugh Knowles Ctr, Evanston, IL 60208 USA
基金
美国国家科学基金会;
关键词
Cochlea; Hemicochlea; Electrical impedance; Four-electrode reflection-coefficient method; GUINEA-PIG COCHLEA; INNER-EAR; RESISTANCE CHANGES; HEMICOCHLEA;
D O I
10.1016/j.heares.2009.10.010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
In individuals with severe-to-profound hearing loss, cochlear implants (CIs) bypass normal inner ear function by applying electrical current directly into the cochlea, thereby stimulating surviving auditory nerve fibers. Although cochlear implants are able to restore some auditory sensation, they are far from providing normal hearing. It has been estimated that up to 75% of the current injected via a Cl is shunted along scala tympani and is not available to stimulate auditory neurons. The path of the injected current and the consequent population of stimulated spiral ganglion cells are dependent upon the positions of the electrode contacts within the cochlea and the impedances of cochlear structures. However, characterization of the current path remains one of the most critical, yet least understood, aspects of cochlear implantation. In particular, the impedances of cochlear structures, including the modiolus, are either unknown or based upon estimates derived from circuit models. Impedance values for many cochlear structures have never been measured. By combining the hemicochlea preparation, a cochlea cut in half along its mid-modiolar plane, and the four-electrode reflection-coefficient technique, impedances can be measured for cochlear tissues in a cochlear cross section including the modiolus. Advantages and disadvantages of the method are discussed in detail and electrical impedance measurements obtained in the gerbil hemicochlea are presented. The resistivity values for the cochlear wall in Omega cm are, 528 (range: 432-708) for scala media 3rd turn, 502 (range: 421-616) for scala tympani 3rd turn and scala vestibuli 2nd turn, 627 (range: 531-759) for scala media 2nd turn, 434 (range: 353-555) for scala tympani 2nd turn and scala vestibuli basal turn, 434 (range: 373-514) for scala media basal turn, and 590 (range: 546-643) for scala tympani basal turn. The resistivity was 455 Omega cm (range: 426-487) for the modiolus. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 40 条
  • [21] Hydrodynamic and electrical considerations in the design of a four-electrode impedance-based microfluidic device (vol 400, pg 1347, 2011)
    Justin, Gusphyl
    Nasir, Mansoor
    Ligler, Frances S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 3177 - 3177
  • [22] SOME MEASUREMENTS OF ABSORPTION COEFFICIENT OF SOIL USING IMPEDANCE TUBE TECHNIQUE
    PROUT, JH
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1961, 33 (06): : 833 - &
  • [23] A Correction for Impedance Measurements Using the Three Point Electrode Technique in SOFCs
    Escobar, J. A.
    Pakalapati, S. R.
    Celik, I. B.
    Finklea, H.
    SOLID OXIDE FUEL CELLS 11 (SOFC-XI), 2009, 25 (02): : 391 - 400
  • [24] Embedded-based Instrumentation System for Electrical Resistivity Measurement on Conductive Concrete using Four-Electrode Method
    Toresano, La Ode Husein Z.
    Prawito
    Sudarmaji, Arief
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS, 2015, : 72 - 79
  • [25] Electrical impedance guides electrode array in cochlear implantation using machine learning and robotic feeder
    Hafeez, Nauman
    Du, Xinli
    Boulgouris, Nikolaos
    Begg, Philip
    Irving, Richard
    Coulson, Chris
    Tourrel, Guillaume
    HEARING RESEARCH, 2021, 412
  • [26] A longitudinal study of electrical stimulation levels and electrode impedance in children using the Clarion cochlear implant
    Henkin, Y
    Kaplan-Neeman, R
    Kronenberg, J
    Migirov, L
    Hildesheimer, M
    Muchnik, C
    ACTA OTO-LARYNGOLOGICA, 2006, 126 (06) : 581 - 586
  • [27] Characterisation of human skin impedance at acupuncture point PC4 Ximen and pericardium meridian using the four-electrode method
    Rezaei, Shinna
    Khorsand, Ali
    Jamali, Jamshid
    ACUPUNCTURE IN MEDICINE, 2012, 30 (02) : 127 - 131
  • [28] On-line control of cellular adhesion with impedance measurements using interdigitated electrode structures
    Ehret, R
    Baumann, W
    Brischwein, M
    Schwinde, A
    Wolf, B
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (03) : 365 - 370
  • [29] On-line control of cellular adhesion with impedance measurements using interdigitated electrode structures
    R. Ehret
    W. Baumann
    M. Brischwein
    A. Schwinde
    B. Wolf
    Medical and Biological Engineering and Computing, 1998, 36 : 365 - 370
  • [30] Study of proton conductivity of composite metal-ceramic materials based on neodimium tugstates using a four-electrode technique with ionic probes
    Uvarov, N. F.
    Ulihin, A. S.
    Bespalko, Yu N.
    Eremeev, N. F.
    Krasnov, A., V
    Skriabin, P., I
    Sadykov, V. A.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (42) : 19521 - 19527