Electrical impedance measurements of cochlear structures using the four-electrode reflection-coefficient technique

被引:9
|
作者
Kumar, Gagan [1 ]
Chokshi, Moulin [1 ]
Richter, Claus-Peter [1 ,2 ,3 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Otolaryngol Head & Neck Surg, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[3] Northwestern Univ, Dept Commun Sci & Disorders, Hugh Knowles Ctr, Evanston, IL 60208 USA
基金
美国国家科学基金会;
关键词
Cochlea; Hemicochlea; Electrical impedance; Four-electrode reflection-coefficient method; GUINEA-PIG COCHLEA; INNER-EAR; RESISTANCE CHANGES; HEMICOCHLEA;
D O I
10.1016/j.heares.2009.10.010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
In individuals with severe-to-profound hearing loss, cochlear implants (CIs) bypass normal inner ear function by applying electrical current directly into the cochlea, thereby stimulating surviving auditory nerve fibers. Although cochlear implants are able to restore some auditory sensation, they are far from providing normal hearing. It has been estimated that up to 75% of the current injected via a Cl is shunted along scala tympani and is not available to stimulate auditory neurons. The path of the injected current and the consequent population of stimulated spiral ganglion cells are dependent upon the positions of the electrode contacts within the cochlea and the impedances of cochlear structures. However, characterization of the current path remains one of the most critical, yet least understood, aspects of cochlear implantation. In particular, the impedances of cochlear structures, including the modiolus, are either unknown or based upon estimates derived from circuit models. Impedance values for many cochlear structures have never been measured. By combining the hemicochlea preparation, a cochlea cut in half along its mid-modiolar plane, and the four-electrode reflection-coefficient technique, impedances can be measured for cochlear tissues in a cochlear cross section including the modiolus. Advantages and disadvantages of the method are discussed in detail and electrical impedance measurements obtained in the gerbil hemicochlea are presented. The resistivity values for the cochlear wall in Omega cm are, 528 (range: 432-708) for scala media 3rd turn, 502 (range: 421-616) for scala tympani 3rd turn and scala vestibuli 2nd turn, 627 (range: 531-759) for scala media 2nd turn, 434 (range: 353-555) for scala tympani 2nd turn and scala vestibuli basal turn, 434 (range: 373-514) for scala media basal turn, and 590 (range: 546-643) for scala tympani basal turn. The resistivity was 455 Omega cm (range: 426-487) for the modiolus. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 40 条
  • [1] Hyperaemia evaluation in clinical diathermy by four-electrode impedance measurements
    Olmi, R
    Bini, M
    Ignesti, A
    Feroldi, P
    Spiazzi, L
    Bodini, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01): : 251 - 261
  • [2] The four-electrode impedance technique: A method for investigation of compliance in luminal organs
    Gregersen, H.
    Stodkilde-Jorgensen, H.
    Djurhuus, J.C.
    Mortensen, S.O.
    Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 61 - 64
  • [3] Hydrodynamic and electrical considerations in the design of a four-electrode impedance-based microfluidic device
    Gusphyl Justin
    Mansoor Nasir
    Frances S. Ligler
    Analytical and Bioanalytical Chemistry, 2011, 400 : 1347 - 1358
  • [4] Hydrodynamic and electrical considerations in the design of a four-electrode impedance-based microfluidic device
    Justin, Gusphyl
    Nasir, Mansoor
    Ligler, Frances S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (05) : 1347 - 1358
  • [5] Electrical impedance spectroscopy measurements using a four-electrode configuration improve on-line monitoring of cell concentration in adherent animal cell cultures
    Sarro, E.
    Lecina, M.
    Fontova, A.
    Sola, C.
    Godia, F.
    Cairo, J. J.
    Bragos, R.
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 257 - 263
  • [6] Erratum to: Hydrodynamic and electrical considerations in the design of a four-electrode impedance-based microfluidic device
    Gusphyl Justin
    Mansoor Nasir
    Frances S. Ligler
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3177 - 3177
  • [7] Impedance measurement using the four electrode technique
    Locke, SE
    Gale, TJ
    Kilpatrick, D
    Proceedings of the Second IASTED International Conference on Biomedical Engineering, 2004, : 594 - 597
  • [8] Parasitic capacitance influence of potential-sensing electrodes on four-electrode liquid impedance measurements
    Mazzeo, Brian A.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (09)
  • [9] RESEARCH ON IRRIGATION MEASUREMENT METHOD FOR EYE USING FOUR-ELECTRODE RHEOGRAPHIC TECHNIQUE
    MOUILLON, M
    BONNET, JL
    PIQUARD, JF
    ANNALES D OCULISTIQUE, 1974, 207 (02): : 129 - 129
  • [10] AC Impedance Characterization of Highly Resistive Media Using Four-Electrode Electrochemical Cells
    Lvovich, Vadim F.
    Smiechowski, Matthew F.
    IMPEDANCE TECHNIQUES: DIAGNOSTICS AND SENSING APPLICATION S, 2010, 25 (32): : 1 - 25