Evaluation of BD Vacutainer® Barricor™ blood collection tubes for routine chemistry testing on a Roche Cobas® 8000 Platform

被引:12
|
作者
Fournier, Jeffrey E. [1 ]
Northrup, Victoria [2 ,3 ]
Clark, Claudette [3 ]
Fraser, Jacqueline [4 ]
Howlett, Michael [4 ,5 ]
Atkinson, Paul [4 ,5 ]
Shea, Jennifer L. [3 ,6 ]
机构
[1] Dalhousie Med Sch, Dalhousie Med New Brunswick, St John, NB, Canada
[2] St Johns Hosp, Dept Res Serv, St John, NB, Canada
[3] St Johns Hosp, Dept Lab Med, St John, NB, Canada
[4] St Johns Hosp, Dept Emergency Med, St John, NB, Canada
[5] Dalhousie Univ, Dept Emergency Med, Halifax, NS, Canada
[6] Dalhousie Univ, Dept Pathol, Halifax, NS, Canada
关键词
Barricor (TM); PST (TM); Roche Cobas 8000; Routine chemistry testing; LITHIUM HEPARIN; CLINICAL-CHEMISTRY; GEL SEPARATOR; SERUM TUBES; II TUBES; STABILITY; ANALYTES; PLASMA; DRUGS; PST;
D O I
10.1016/j.clinbiochem.2018.06.002
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Barricor (TM) Vacutainers (R) are a novel non-gel separator blood collection tube. These tubes enable faster pre-analytical processing which could reduce turnaround time and be beneficial in an acute care setting. We sought to evaluate the bias, stability, and integrity of plasma generated from these tubes compared to Plasma Separator Tubes (TM) (PST) for 50 routine chemistry analyzes on a Roche Cobas (R) 8000 analyzer. Methods: Paired samples were collected from 150 patients originating in the emergency department and outpatient collections at the Saint John Regional Hospital. Barricor (TM) vacutainers were centrifuged for 3 min at 4000g and PST (TM) vacutainers for 10 min at 1300 g within two hours of collection. Plasma samples (n. = 126) were then analyzed for 50 chemistry analyzes and bias determined between tubes. Ten-day stability of AST, glucose, potassium, phosphate, and LDH was also assessed in a subset of paired samples (n. = 4). Lastly, the quality of plasma (n. = 20) was assessed through measurement of cell counts on a DxH Hematology Analyzer. Results: All 50 analyzes demonstrated comparable results across a broad concentration range between Barricor (TM) and PST (TM) vacutainers (average percent bias - 1.5% to 6.1%; Deming linear regression slopes 0.933-1.041; correlation coefficients >= 0.9144). AST, potassium, glucose and LDH were stable for 10 days in Barricor (TM) vacutainers (change from baseline < 10%) but < 5 days in PST (TM) vacutainers while phosphate was stable for 4 days in Barricor (TM) vs 2 days in PST (TM) vacutainers. Platelet counts were statistically lower in Barricor (TM) compared to PST (TM) vacutainers. Conclusion: Our data suggest that Barricor (TM) vacutainers are an acceptable alternative to PST (TM) vacutainers while offering the added benefit of decreased pre-analytical processing time, increased stability of certain analyzes, and possibly less cellular contamination.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 33 条
  • [1] Evaluation of BD BarricorTM and PSTTM blood collection tubes compared to serum for testing 11 therapeutic drugs on a Roche Cobas® 8000 platform
    Jordan, Alexander
    Sherazi, Ali
    Stevens, Ashley
    Franks, Christina Quondam
    Sturgeon, Kayla
    Northrup, Victoria
    Shea, Jennifer L.
    CLINICAL BIOCHEMISTRY, 2022, 100 : 60 - 66
  • [2] Verification of BD Vacutainer® Barricor™ plasma blood collection tube
    Smolcic, V. Supak
    Ongaro, L.
    Bilic-Zulle, L.
    CLINICA CHIMICA ACTA, 2019, 493 : S524 - S524
  • [3] Impact of recentrifugation of blood collection tubes on chemistry and immunochemistry analytes after 24 and 72 hours of refrigerated storage on the Roche Cobas 8000 platform
    Bowen, Raffick A. R.
    Esguerra, Vanessa
    Walker, Maria
    Cheng, Phil
    Nguyen, Thanh
    CLINICA CHIMICA ACTA, 2022, 531 : 342 - 351
  • [4] Evaluation of the BD Vacutainer® RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study
    Kocijancic, Marija
    Cargonja, Jelena
    Delic-Knezevic, Alma
    BIOCHEMIA MEDICA, 2014, 24 (03) : 368 - 375
  • [5] Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes
    Cadamuro, Janne
    Mrazek, Cornelia
    Leichtle, Alexander B.
    Kipman, Ulrike
    Felder, Thomas K.
    Wiedemann, Helmut
    Oberkofler, Hannes
    Fiedler, Georg M.
    Haschke-Becher, Elisabeth
    BIOCHEMIA MEDICA, 2018, 28 (01)
  • [6] Evaluation of the BD Vacutainer® PST™ II Blood Collection Tube for special chemistry analytes
    Chance, Jeffrey
    Berube, Julie
    Vandersmissen, Marita
    Blanckaert, Norbert
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (03) : 358 - 361
  • [7] Evaluation of BD Barricor™ Plasma Blood Collection Tube for Biochemical Tests
    Kosem, Arzu
    Topcuoglu, Canan
    Sezer, Sevilay
    Cevher, Simal K.
    Yenigun, Ezgi C.
    Dede, Fatih
    Turhan, Turan
    CLINICAL LABORATORY, 2019, 65 (12) : 2315 - 2327
  • [8] Switching from serum to plasma: Implementation of BD Vacutainer® Barricor™ Plasma Blood Collection Tubes improves sample quality and laboratory turnaround time
    Ramakers, Christian
    Meyer, Brendan
    Yang, Wanfei
    Plokhoy, Elizabeth
    Xiong, Yan
    Church, Stephen
    Kaushik, Nitin
    PRACTICAL LABORATORY MEDICINE, 2020, 18
  • [9] Evaluation of utility of BD vacutainer barricor for clinical routine biochemical analytes in hemodialysis patients receiving anticoagulant therapy
    Shin, J.
    Choi, H.
    Kee, S.
    Shin, M.
    Shin, J.
    CLINICA CHIMICA ACTA, 2022, 530 : S417 - S417
  • [10] Evaluation of BD Vacutainer SST™ II Plus Tubes for Special Proteins Testing
    Li, Zhiyan
    Yan, Cunling
    Yan, Rong
    Zheng, Xinzhi
    Feng, Zhenru
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2011, 25 (03) : 203 - 206