Accuracy estimation in freehand ultrasound probe calibration

被引:0
|
作者
Moghari, Mehdi H. [1 ]
Chen, Thomas K. [2 ]
Abolmaesumi, Purang [1 ,2 ]
机构
[1] Queens Univ, Dept Elect & Comp Engn, Kingston, ON, Canada
[2] Queens Univ, Sch Comp, Kingston, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
freehand ultrasound imaging; ultrasound probe calibration; unscented Kalman filter; confidence interval; calibration residual error;
D O I
10.1117/12.708537
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional, freehand ultrasound is an imaging technique that has seen increasing applications in computer assisted surgery. A key element of this technique is image calibration, in order to estimate a three-dimensional homogeneous transformation that maps the position of individual pixels from the ultrasound image coordinate to the ultrasound probe coordinate frames. The transformation is typically calculated through imaging a calibration phantom of known geometry, and solving for the transformation parameters (either in closed-form or iteratively) The calibration error achieved through this process is usually assumed to be constant for all the pixels in the image. In this paper, we propose a novel method to estimate the calibration accuracy for individual pixels within an ultrasound image by employing the Unscented Kalman Filter (UKF). Based on the variances of calibration parameters extracted by UKF, a mean square residual error is estimated for each individual pixel in the ultrasound image. We demonstrate that the calibration error could in fact significantly vary for different pixels in the image. This observation could potentially impact the image registration process in computer assisted surgery applications. The method has been validated through simulations and experiments.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Quantitative evaluation of three calibration methods for 3-D freehand ultrasound
    Rousseau, Francois
    Hellier, Pierre
    Letteboer, Marloes M. J.
    Niessen, Wiro J.
    Barillot, Christian
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) : 1492 - 1501
  • [42] COMPARISON OF FREEHAND 3-D ULTRASOUND CALIBRATION TECHNIQUES USING A STYLUS
    Hsu, Po-Wei
    Treece, Graham M.
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (10): : 1610 - 1621
  • [43] Freehand 3D ultrasound calibration using an electromagnetically tracked needle
    Zhang, Hui
    Banovac, Filip
    White, Amy
    Cleary, Kevin
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [44] Probe Localization for Freehand 3D Ultrasound by Tracking Skin Features
    Sun, Shih-Yu
    Gilbertson, Matthew
    Anthony, Brian W.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT II, 2014, 8674 : 365 - 372
  • [45] Novel Geometric Technique of Ultrasound Probe Calibration
    Choroba, Beata
    Pycinski, Bartlomiej
    Krecichwost, Michal
    Spinczyk, Dominik
    Pietka, Ewa
    INFORMATION TECHNOLOGY IN BIOMEDICINE (ITIB 2018), 2019, 762 : 182 - 193
  • [46] An image registration based ultrasound probe calibration
    Li, Xin
    Kumar, Dinesh
    Sarkar, Saradwata
    Narayanan, Ram
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [47] Calibration of Freehand Ultrasound Based on YOLOv8x Keypoints Detection Network
    Peng, Fan
    Cui, Shangqi
    Wang, Binbin
    Wang, Dan
    Shi, Zhe
    Li, Lanlin
    Yang, Zhi
    PROCEEDINGS OF 2023 4TH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL INTELLIGENCE FOR MEDICINE SCIENCE, ISAIMS 2023, 2023, : 167 - 171
  • [48] User-friendly freehand ultrasound calibration using Lego bricks and automatic registration
    Xiao, Yiming
    Yan, Charles Xiao Bo
    Drouin, Simon
    De Nigris, Dante
    Kochanowska, Anna
    Collins, D. Louis
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (09) : 1703 - 1711
  • [49] User-friendly freehand ultrasound calibration using Lego bricks and automatic registration
    Yiming Xiao
    Charles Xiao Bo Yan
    Simon Drouin
    Dante De Nigris
    Anna Kochanowska
    D. Louis Collins
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1703 - 1711
  • [50] Confhusius: A robust and fully automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    MEDICAL IMAGE ANALYSIS, 2005, 9 (01) : 25 - 38