Accuracy estimation in freehand ultrasound probe calibration

被引:0
|
作者
Moghari, Mehdi H. [1 ]
Chen, Thomas K. [2 ]
Abolmaesumi, Purang [1 ,2 ]
机构
[1] Queens Univ, Dept Elect & Comp Engn, Kingston, ON, Canada
[2] Queens Univ, Sch Comp, Kingston, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
freehand ultrasound imaging; ultrasound probe calibration; unscented Kalman filter; confidence interval; calibration residual error;
D O I
10.1117/12.708537
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional, freehand ultrasound is an imaging technique that has seen increasing applications in computer assisted surgery. A key element of this technique is image calibration, in order to estimate a three-dimensional homogeneous transformation that maps the position of individual pixels from the ultrasound image coordinate to the ultrasound probe coordinate frames. The transformation is typically calculated through imaging a calibration phantom of known geometry, and solving for the transformation parameters (either in closed-form or iteratively) The calibration error achieved through this process is usually assumed to be constant for all the pixels in the image. In this paper, we propose a novel method to estimate the calibration accuracy for individual pixels within an ultrasound image by employing the Unscented Kalman Filter (UKF). Based on the variances of calibration parameters extracted by UKF, a mean square residual error is estimated for each individual pixel in the ultrasound image. We demonstrate that the calibration error could in fact significantly vary for different pixels in the image. This observation could potentially impact the image registration process in computer assisted surgery applications. The method has been validated through simulations and experiments.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Image-based method for in-vivo freehand ultrasound calibration
    Wein, Wolfgang
    Khamene, Ali
    MEDICAL IMAGING 2008: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2008, 6920
  • [22] Rapid Calibration of 3D Freehand Ultrasound for Vessel Intervention
    Luan, K.
    Liao, H.
    Ohya, T.
    Wang, J.
    Sakuma, I.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 716 - +
  • [23] Rapid, easy and reliable calibration for freehand 3D ultrasound
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06): : 823 - 835
  • [24] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Graham, Andrew H. Gee
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [25] Quantitative Assessments for Ultrasound Probe Calibration
    Chen, Elvis C. S.
    Ma, Burton
    Peters, Terry M.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT IV, 2021, 12904 : 363 - 372
  • [26] Accurate fiducial location for freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [27] A review of calibration techniques for freehand 3-D ultrasound systems
    Mercier, L
    Lango, T
    Lindseth, F
    Collins, LD
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (02): : 143 - 165
  • [28] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (02): : 239 - 251
  • [29] Probe trajectory interpolation for 3D reconstruction of freehand ultrasound
    Coupe, Pierrick
    Hellier, Pierre
    Morandi, Xavier
    Barillot, Christian
    MEDICAL IMAGE ANALYSIS, 2007, 11 (06) : 604 - 615
  • [30] 3D freehand ultrasound reconstruction based on probe trajectory
    Coupé, P
    Hellier, P
    Azzabou, N
    Barillot, C
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 597 - 604