摘要
In Saudi Arabia, air-conditioners ACs are responsible for 50% of electricity consumption due to hot weather conditions as well as the delay in implementing ACs standards. In this work, six used split-type and eight used window-type ACs that have ages from 3 to 32 years were tested according to American Society of Heating, Refrigerating and Air-Conditioning Engineers and Saudi Standard, Metrology and Quality Organization cooling test conditions and their performances were compared against new units that have 5.27 kW rated capacity. Test results show that coefficient of performance and cooling capacity of used split-type units compared to new one are 68% and 93%, respectively. For window-type, test results show that coefficient of performance and cooling capacity of used units compared to new one are 55% and 77%, respectively. The effect of replacing used compressor units with a new compressor was experimentally investigated. A model was developed using a commercially available software and was validated with experimental data. An economical map was developed to identify feasible ACs replacement regions.
引用
收藏
页码:586 / 602
页数:17
相关论文
共 42 条
  • [1] Experimental Investigation of Potential Energy Savings and Payback Periods in Renewing Old Split-Type Air Conditioners
    Alabdulkarem, Abdullah
    Almutairi, Zeyad
    Alqahtani, Turki
    Alshahrani, Majed
    Alawaad, Khaled
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [2] Optimum placement of condensing units of split-type air-conditioners by numerical simulation
    Avara, Abdollah
    Daneshgar, Ehsan
    ENERGY AND BUILDINGS, 2008, 40 (07) : 1268 - 1272
  • [3] Window-type room air conditioners
    Rosenquist, G
    ASHRAE JOURNAL, 1999, 41 (01) : 31 - 36
  • [4] Numerical Study of an Ejector as an Expansion Device in Split-type Air Conditioners for Energy Savings
    Sumeru, Kasni
    Sulaimon, Shodiya
    Ani, Farid Nasir
    Nasution, Henry
    JOURNAL OF ENGINEERING AND TECHNOLOGICAL SCIENCES, 2013, 45 (02): : 179 - 192
  • [5] Influence of clearances on the energy performance of window-type air-conditioners at the same level outside residential buildings
    Bojic, M
    Lee, M
    Yik, F
    Burnett, J
    BUILDING AND ENVIRONMENT, 2002, 37 (07) : 713 - 726
  • [6] Placement of condensing units of split-type air-conditioners at low-rise residences
    Chow, TT
    Lin, Z
    Yang, XY
    APPLIED THERMAL ENGINEERING, 2002, 22 (13) : 1431 - 1444
  • [7] Use of peripheral fins for R-290 charge reduction in split-type residential air-conditioners
    Ribeiro, Guilherme B.
    Barbosa Jr, Jader R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 1 - 6
  • [8] A Study of Effects of Surrounding Structures towards Airflow Performance in the Outdoor Unit of Split-type Air-conditioners
    Wei, Eric Phan Tze
    Shukor, Mohd Hamdi Abdul
    RECENT ADVANCES IN FLUID MECHANICS, 2009, : 15 - 21
  • [9] Development of a performance booster for the evaporator of window-type air conditioners
    Jheng-Yi Li
    Tun-Ping Teng
    Journal of Mechanical Science and Technology, 2018, 32 : 3955 - 3964
  • [10] Development of a performance booster for the evaporator of window-type air conditioners
    Li, Jheng-Yi
    Teng, Tun-Ping
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (08) : 3955 - 3964