Echocardiographic measurement of cardiac output in rats

被引:71
|
作者
Slama, M
Susic, D
Varagic, J
Ahn, J
Frohlich, ED
机构
[1] Alton Ochsner Med Fdn & Ochsner Clin, Div Res, New Orleans, LA 70121 USA
[2] Univ Picardie, Fac Med, Lab Pharmacol & Physiopathol Cardiovasc, F-80054 Amiens, France
关键词
Doppler; blood volume changes;
D O I
10.1152/ajpheart.00653.2002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The systematic evaluation of different transthoracic echocardiographic (TTE) methods to determine cardiac output (CO) and the effect of changes in intravascular volume on echocardiographically determined indexes of cardiovascular structure in the rat has not been documented. With the use of 11 Wistar rats, simultaneous echocardiographic and thermodilution measurements of CO were compared at baseline and after blood withdrawal or transfusion at 43 different levels of intravascular volume and using 10 different echocardiographic approaches. The best correlation (r = 0.93; P < 0.0001), least bias (-3 ml/min), and best precision (16 ml/min) between thermodilution and echocardiographic methods were obtained at the level of aortic annulus using pulsed Doppler. In conclusion, CO could be accurately assessed in rats using TTE and pulsed Doppler at the level of the aortic annulus. This annulus was demonstrated to remain stable, but pulmonary annulus, thoracic aorta, mitral valve, and left ventricular diameters were found to be more modifiable during volumic changes.
引用
收藏
页码:H691 / H697
页数:7
相关论文
共 50 条
  • [1] Echocardiographic automated cardiac output measurement of pulmonary output and quantification of intracardiac shunt
    Mansencal, N
    Martin, F
    Farcot, JC
    Digne, F
    Joseph, T
    Pilliére, R
    Redheuil, A
    Lacombe, P
    Dubourg, O
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (01) : 25 - 31
  • [2] Echocardiographic automated cardiac output measurement of pulmonary output and quantification of intracardiac shunt
    Mansencal, N.
    Martin, F.
    Farcot, J. C.
    Digne, F.
    Joseph, T.
    Pilliere, R.
    Lacombe, P.
    Dubourg, O.
    EUROPEAN HEART JOURNAL, 2005, 26 : 231 - 231
  • [3] MEASUREMENT OF DISTRIBUTION OF CARDIAC OUTPUT IN UNANESTHETIZED RATS
    SASAKI, Y
    WAGNER, HN
    JOURNAL OF APPLIED PHYSIOLOGY, 1971, 30 (06) : 879 - &
  • [4] DOPPLER-ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT AT THE LEVEL OF THE 4 CARDIAC VALVES
    GAUDREAULT, G
    DUMESNIL, JG
    LEBLANC, MH
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1992, 41 (05): : 267 - 271
  • [5] COMBINED DOPPLER PHASED-ARRAY ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT
    MAGNIN, PA
    STEWART, JA
    MYERS, S
    VONRAMM, O
    KISSLO, J
    CIRCULATION, 1979, 60 (04) : 153 - 153
  • [6] Doppler and Volumetric Echocardiographic Methods for Cardiac Output Measurement in Standing Adult Horses
    McConachie, E.
    Barton, M. H.
    Rapoport, G.
    Giguere, S.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2013, 27 (02) : 324 - 330
  • [7] DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT USING AN IMPLANTABLE AORTIC TRANSDUCER
    STEWART, WJ
    SCHIAVONE, WA
    SALCEDO, EE
    ROM, P
    CHAVEZ, AM
    COSGROVE, DM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A229 - A229
  • [8] TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT BY THE MITRAL ANNULUS METHOD
    SHIMAMOTO, H
    KITO, H
    KAWAZOE, K
    FUJITA, T
    SHIMAMOTO, Y
    BRITISH HEART JOURNAL, 1992, 68 (05): : 510 - 515
  • [9] COMBINED DOPPLER AND ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT - THEORY AND APPLICATION IN PREGNANCY
    ROBSON, SC
    DUNLOP, W
    MOORE, M
    HUNTER, S
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (11): : 1014 - 1027
  • [10] DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT USING THE MITRAL ORIFICE METHOD
    ZHANG, Y
    NITTERHAUGE, S
    IHLEN, H
    MYHRE, E
    BRITISH HEART JOURNAL, 1985, 53 (02): : 130 - 136