An embedded microretroreflector-based microfluidic immunoassay platform

被引:6
|
作者
Raja, Balakrishnan [1 ]
Pascente, Carmen [3 ]
Knoop, Jennifer [1 ]
Shakarisaz, David [3 ]
Sherlock, Tim [3 ]
Kemper, Steven [1 ]
Kourentzi, Katerina [1 ]
Renzi, Ronald F. [5 ]
Hatch, Anson V. [4 ]
Olano, Juan [6 ]
Peng, Bi-Hung [6 ]
Ruchhoeft, Paul [3 ]
Willson, Richard [1 ,2 ]
机构
[1] Univ Houston, Dept Chem & Biomol Engn, Houston, TX USA
[2] Tecnol Monterrey, Ctr Biotecnol FEMSA, Campus Monterrey, Monterrey, Nuevo Leon, Mexico
[3] Univ Houston, Dept Elect & Comp Engn, Houston, TX USA
[4] Sandia Natl Labs, Dept Biotechnol & Bioengn, Livermore, CA USA
[5] Sandia Natl Labs, Adv Syst Engn & Deployment, Livermore, CA USA
[6] Univ Texas Med Branch, Dept Pathol, Galveston, TX 77555 USA
基金
美国国家科学基金会;
关键词
FORCE DISCRIMINATION ASSAYS; ATTOMOLAR PROTEIN-DETECTION; SURFACE-PLASMON RESONANCE; GRATING COUPLER; PORE SENSORS; BIOSENSOR; DNA; IMMUNOSENSOR; FLOW; NANOPARTICLES;
D O I
10.1039/c6lc00038j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a microfluidic immunoassay platform based on the use of linear microretroreflectors embedded in a transparent polymer layer as an optical sensing surface, and micron-sized magnetic particles as light-blocking labels. Retroreflectors return light directly to its source and are highly detectable using inexpensive optics. The analyte is immuno-magnetically pre-concentrated from a sample and then captured on an antibody-modified microfluidic substrate comprised of embedded microretroreflectors, thereby blocking reflected light. Fluidic force discrimination is used to increase specificity of the assay, following which a difference imaging algorithm that can see single 3 mu m magnetic particles without optical calibration is used to detect and quantify signal intensity from each sub-array of retroreflectors. We demonstrate the utility of embedded microretroreflectors as a new sensing modality through a proof-of-concept immunoassay for a small, obligate intracellular bacterial pathogen, Rickettsia conorii, the causative agent of Mediterranean Spotted Fever. The combination of large sensing area, optimized surface chemistry and microfluidic protocols, automated image capture and analysis, and high sensitivity of the difference imaging results in a sensitive immunoassay with a limit of detection of roughly 4000 R. conorii per mL.
引用
收藏
页码:1625 / 1635
页数:11
相关论文
共 50 条
  • [41] Microfluidic channel with embedded SERS 2D platform for the aptamer detection of ochratoxin A
    Galarreta, Betty C.
    Tabatabaei, Mohammadali
    Guieu, Valerie
    Peyrin, Eric
    Lagugne-Labarthet, Francois
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (05) : 1613 - 1621
  • [42] Versatile microfluidic platform embedded with sidewall three-dimensional electrodes for cell manipulation
    Puttaswamy, Srinivasu Valagerahally
    Fishlock, Sam Jeffery
    Steele, David
    Shi, Qiongfeng
    Lee, Chengkuo
    McLaughlin, James
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [43] Microfluidic channel with embedded SERS 2D platform for the aptamer detection of ochratoxin A
    Betty C. Galarreta
    Mohammadali Tabatabaei
    Valérie Guieu
    Eric Peyrin
    François Lagugné-Labarthet
    Analytical and Bioanalytical Chemistry, 2013, 405 : 1613 - 1621
  • [44] The LabCD™:: A centrifuge-based microfluidic platform for diagnostics
    Madou, MJ
    Kellogg, GJ
    SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY, PROCEEDINGS OF, 1998, 3259 : 80 - 93
  • [45] A microfluidic AFM cantilever based dispensing and aspiration platform
    van Oorschot, Ralph
    Garza, Hector Hugo Perez
    Derks, Roy J. S.
    Staufer, Urs
    Ghatkesar, Murali Krishna
    EPJ TECHNIQUES AND INSTRUMENTATION, 2015, 2
  • [46] Aptamer-based thrombin assay on microfluidic platform
    Chen, Fang-yuan
    Wang, Zheng
    Li, Peng
    Lian, Hong-Zhen
    Chen, Hong-Yuan
    ELECTROPHORESIS, 2013, 34 (24) : 3260 - 3266
  • [47] Thread based microfluidic platform for urinary creatinine analysis
    Arroyo, Manuel J.
    Erenas, Miguel M.
    de Orbe-Paya, Ignacio
    Cantrell, Kevin
    Dobado, Jose A.
    Ballester, Pablo
    Blondeau, Pascal
    Salinas-Castillo, Alfonso
    Fermin Capitan-Vallvey, Luis
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 305
  • [48] A novel microfluidic chip based on an impedance-enhanced electrochemical immunoassay
    Tsai, Sung-Lin
    Wey, Jiunn-Jye
    Lai, Szu-Chia
    Huang, Yu-Yin
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [49] Quantification of bacterial cells based on autofluorescence on a microfluidic platform
    Bao, Ning
    Jagadeesan, Balarnurugan
    Bhunia, Arun K.
    Yao, Yuan
    Lu, Chang
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1181 (1-2) : 153 - 158
  • [50] A BIOLOGICAL MONITORING MODULE BASED ON A CERAMIC MICROFLUIDIC PLATFORM
    Smetana, Walter
    Balluch, Bruno
    Atassi, Ibrahim
    Gvichiya, Khatuna Elizbarowna
    Gaubitzer, Erwin
    Edetsberger, Michael
    Koehler, Gottfried
    BIODEVICES 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2009, : 75 - +