An embedded microretroreflector-based microfluidic immunoassay platform

被引:6
|
作者
Raja, Balakrishnan [1 ]
Pascente, Carmen [3 ]
Knoop, Jennifer [1 ]
Shakarisaz, David [3 ]
Sherlock, Tim [3 ]
Kemper, Steven [1 ]
Kourentzi, Katerina [1 ]
Renzi, Ronald F. [5 ]
Hatch, Anson V. [4 ]
Olano, Juan [6 ]
Peng, Bi-Hung [6 ]
Ruchhoeft, Paul [3 ]
Willson, Richard [1 ,2 ]
机构
[1] Univ Houston, Dept Chem & Biomol Engn, Houston, TX USA
[2] Tecnol Monterrey, Ctr Biotecnol FEMSA, Campus Monterrey, Monterrey, Nuevo Leon, Mexico
[3] Univ Houston, Dept Elect & Comp Engn, Houston, TX USA
[4] Sandia Natl Labs, Dept Biotechnol & Bioengn, Livermore, CA USA
[5] Sandia Natl Labs, Adv Syst Engn & Deployment, Livermore, CA USA
[6] Univ Texas Med Branch, Dept Pathol, Galveston, TX 77555 USA
基金
美国国家科学基金会;
关键词
FORCE DISCRIMINATION ASSAYS; ATTOMOLAR PROTEIN-DETECTION; SURFACE-PLASMON RESONANCE; GRATING COUPLER; PORE SENSORS; BIOSENSOR; DNA; IMMUNOSENSOR; FLOW; NANOPARTICLES;
D O I
10.1039/c6lc00038j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a microfluidic immunoassay platform based on the use of linear microretroreflectors embedded in a transparent polymer layer as an optical sensing surface, and micron-sized magnetic particles as light-blocking labels. Retroreflectors return light directly to its source and are highly detectable using inexpensive optics. The analyte is immuno-magnetically pre-concentrated from a sample and then captured on an antibody-modified microfluidic substrate comprised of embedded microretroreflectors, thereby blocking reflected light. Fluidic force discrimination is used to increase specificity of the assay, following which a difference imaging algorithm that can see single 3 mu m magnetic particles without optical calibration is used to detect and quantify signal intensity from each sub-array of retroreflectors. We demonstrate the utility of embedded microretroreflectors as a new sensing modality through a proof-of-concept immunoassay for a small, obligate intracellular bacterial pathogen, Rickettsia conorii, the causative agent of Mediterranean Spotted Fever. The combination of large sensing area, optimized surface chemistry and microfluidic protocols, automated image capture and analysis, and high sensitivity of the difference imaging results in a sensitive immunoassay with a limit of detection of roughly 4000 R. conorii per mL.
引用
收藏
页码:1625 / 1635
页数:11
相关论文
共 50 条
  • [21] Rapid parallel blood typing on centrifugal microfluidic platform by microcolumn gel immunoassay
    Wan, Yaru
    Zhang, Mingyu
    Liu, Zetai
    Wang, Bangfeng
    Liu, Yangcheng
    Chen, Peng
    Li, Yiwei
    Du, Wei
    Feng, Xiaojun
    Liu, Bi-Feng
    TALANTA, 2025, 282
  • [22] High throughput multilayer microfluidic particle separation platform using embedded thermoplastic-based micropumping
    Didar, Tohid Fatanat
    Li, Kebin
    Tabrizian, Maryam
    Veres, Teodor
    LAB ON A CHIP, 2013, 13 (13) : 2615 - 2622
  • [23] A printed circuit board platform embedded a piezoelectric device and microfluidic networks
    Zhang, An-Liang
    Zhang, Xiao-Quan
    Hu, Wen-Yan
    Fu, Xiang-Ting
    FERROELECTRICS, 2016, 502 (01) : 69 - 75
  • [24] Microfluidic heavy metal immunoassay based on absorbance measurement
    Date, Yasumoto
    Terakado, Shingo
    Sasaki, Kazuhiro
    Aota, Arata
    Matsumoto, Norio
    Shiku, Hitoshi
    Ino, Kosuke
    Watanabe, Yoshitomo
    Matsue, Tomokazu
    Ohmura, Naoya
    BIOSENSORS & BIOELECTRONICS, 2012, 33 (01): : 106 - 112
  • [25] Yeast surface display-based microfluidic immunoassay
    Wang, Jing
    Cheng, Danhui
    Chan, Jay Kwok-Lun
    Luo, Xiaoteng
    Wu, Hongkai
    Hsing, I-Ming
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 878 - 883
  • [26] Simple, rapid, and accurate malaria diagnostic platform using microfluidic-based immunoassay of Plasmodium falciparum lactate dehydrogenase
    Lee, Wang Sik
    Kang, Taejoon
    Kwak, Kyung Jin
    Park, Kyoungsook
    Yi, So Yeon
    Lee, Ui Jin
    Shin, Yong Beom
    Jeong, Jinyoung
    NANO CONVERGENCE, 2020, 7 (01)
  • [27] Simple, rapid, and accurate malaria diagnostic platform using microfluidic-based immunoassay of Plasmodium falciparum lactate dehydrogenase
    Wang Sik Lee
    Taejoon Kang
    Kyung Jin Kwak
    Kyoungsook Park
    So Yeon Yi
    Ui Jin Lee
    Yong Beom Shin
    Jinyoung Jeong
    Nano Convergence, 7
  • [28] A microfluidic immunoassay platform for the detection of free prostate specific antigen: a systematic and quantitative approach
    Madaboosi, Narayanan
    Soares, Ruben R. G.
    Chu, Virginia
    Conde, Joao Pedro
    ANALYST, 2015, 140 (13) : 4423 - 4433
  • [29] Chemiluminescence immunoassay for a nonionic surfactant using a compact disc-type microfluidic platform
    Guo, Shuai
    Nakano, Koji
    Nakajima, Hizuru
    Uchiyama, Katsumi
    Hemmi, Akihide
    Yamasaki, Yoshikazu
    Morooka, Shigeharu
    Ishimatsu, Ryoichi
    Imato, Toshihiko
    PURE AND APPLIED CHEMISTRY, 2012, 84 (10) : 2027 - 2043
  • [30] Plasmonic nanopillar array embedded microfluidic chips: an in situ SERS monitoring platform
    Zhao, Yingqi
    Zhang, Yong-Lai
    Huang, Jian-An
    Zhang, Zhenyu
    Chen, Xianfeng
    Zhang, Wenjun
    JOURNAL OF MATERIALS CHEMISTRY A, 2015, 3 (12) : 6408 - 6413