Applicability evaluation of direct metal tooling-based additive manufacturing for reducing ceramic liner fracture in total hip arthroplasty

被引:8
|
作者
Shin, Taejin [1 ,2 ]
Kim, Yong-Sik [3 ]
Kim, Jungsung [4 ]
Lee, Kwon-Yong [1 ]
Lee, Sung-Jae [5 ]
Sun, DooHoon [6 ]
Lim, Young-Wook [3 ]
Lim, Dohyung [1 ]
机构
[1] Sejong Univ, Dept Mech Engn, 209 Neungdong Ro, Seoul 05006, South Korea
[2] Corentec Co Ltd, Cent R&D Ctr, Seoul 06541, South Korea
[3] Catholic Univ Korea, Seoul St Marys Hosp, Sch Med, Dept Orthopaed Surg, Seoul 06591, South Korea
[4] Konyang Univ, Dept Biomed Mat, Daejeon 35365, South Korea
[5] Inje Univ, Dept Biomed Engn, Gimhae 621749, South Korea
[6] Sun Med Ctr, Dept Orthopaed Surg, Daejeon 34811, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Additive manufacturing; Ceramic liner fracture; Acetabular cup deformation; Direct metal tooling; Titanium plasma spray; SQUEAKING HIP; DEFORMATION; BEARINGS;
D O I
10.1016/j.surfcoat.2018.04.030
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Recently, the combination of a press-fit acetabular cup and ceramic articulation has been widely used for implanting cementless acetabular components and has been shown to provide good initial stability. However, this combination may lead to the failure of ceramic liners by their non-concentric seating due to acetabular cup deformation. To reduce the risk of this, we applied direct metal tooling (DMT)-based additive manufacturing (AM) with the hypothesis that DMT-based AM would minimize the deformation of the acetabular cup by increasing its strength, which would ultimately prevent the ceramic liner from fracturing. To confirm this, we performed post-fatigue tests simulating a press-fit situation for the acetabular cups subjected to DMT-based AM and compared them with the cups treated with titanium plasma spray (TPS). The post-fatigue tests were then performed under a maximum load of 14 kN for 20 x 10(7) cycles. The roundness and inner diameter of the cups and liners were measured in all testing phases. The results revealed no differences between the acetabular cups subjected to DMT-based AM and TPS. However, when comparing only the mean values directly, the results for the acetabular cup subjected to DMT-based AM indicated that it might have increased the strength of the acetabular cup, compared with those treated with TPS, thereby minimizing the possibility of fracture of the ceramic liner. In conclusion, DMT-based AM was shown to be at least equivalent to TPS, or could possibly supersede it. Additionally, via DMT-based AM, it is possible to control the porous structure freely, so this approach allows a greater range of applications and potential for further improvement than TPS.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 27 条
  • [1] Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup
    Dragos Popescu
    X. Gallart
    S. Garcia
    G. Bori
    X. Tomas
    J. Riba
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 783 - 785
  • [2] Ceramic Liner Fracture in Total Hip Arthroplasty: A Case Report
    Tashtanov, Baikozho R.
    Korytkin, Andrey A.
    V. Pavlov, Vitalii
    Shubnyakov, Igor I.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2022, 28 (03): : 63 - 73
  • [3] Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup
    Popescu, Dragos
    Gallart, X.
    Garcia, S.
    Bori, G.
    Tomas, X.
    Riba, J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (08) : 783 - 785
  • [4] Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
    Hasegawa, M
    Sudo, A
    Hirata, H
    Uchida, A
    JOURNAL OF ARTHROPLASTY, 2003, 18 (05): : 658 - 661
  • [5] Fracture of a Metal-Backed Ceramic Liner After Total Hip Arthroplasty: A Case Report
    Diciurcio, William
    Lutz, Rex W.
    Smith, Eric B.
    Deirmengian, Gregory K.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [6] Risk factors for ceramic liner fracture after total hip arthroplasty
    Traina, Francesco
    De Fine, Marcello
    Bordini, Barbara
    Toni, Aldo
    HIP INTERNATIONAL, 2012, 22 (06) : 607 - 614
  • [7] Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty
    Lee, Young-Kyun
    Lim, Jae-Young
    Ha, Yong-Chan
    Kim, Tae-Young
    Jung, Woon-Hwa
    Koo, Kyung-Hoi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (07) : 1155 - 1162
  • [8] Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty
    Young-Kyun Lee
    Jae-Young Lim
    Yong-Chan Ha
    Tae-Young Kim
    Woon-Hwa Jung
    Kyung-Hoi Koo
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1155 - 1162
  • [9] Metal Neck and Liner Impingement in Ceramic Bearing Total Hip Arthroplasty
    Lee, Young-Kyun
    Yoo, Jeong Loon
    Koo, Kyung-Hoi
    Yoon, Kang Sup
    Kim, Hee Jong
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (02) : 218 - 222
  • [10] Protrusion of acetabular screws as a cause of liner fracture in ceramic-on-ceramic total hip arthroplasty
    Natera Cisneros, L.
    Crusi, X.
    TRAUMA-SPAIN, 2014, 25 (01): : 37 - 39