Stability indicating reverse phase (RP)-high-performance liquid chromatography method development and validation for the simultaneous estimation of olanzapine and samidorphan in bulk and tablets

被引:3
|
作者
Kumar, Hathibelagal Mundarinti [1 ,2 ,4 ,5 ]
Chandrasekhar, Kothapalli [3 ]
机构
[1] Jawaharlal Nehru Technol Univ, Dept Pharmaceut Sci, Anantapur, India
[2] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool, India
[3] Krishna Univ, Dept Chem, Machilipatnam, Andhra Pradesh, India
[4] Jawaharlal Nehru Technol Univ Anantapur, Ananthapuramu & Dept Pharm, Sri G Pullareddy Govt Polytech, BThandrapadu, Kurnool 518007, Andhra Pradesh, India
[5] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool 518007, Andhra Pradesh, India
关键词
high-performance liquid chromatography method; olanzapine; samidorphan; stability indicating and validation; PROCESS-RELATED IMPURITIES; SCHIZOPHRENIA; FLUOXETINE; HPLC; SPECTROPHOTOMETRY; BIOEQUIVALENCE; FORMULATIONS;
D O I
10.4103/epj.epj_64_21
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background Patients with schizophrenia are given a combination tablet combining olanzapine (OLA), an atypical antipsychotic and samidorphan (SAM), an opioid receptor antagonist. Objectives In bulk and tablet dosage forms, a stability-indicating reverse phase (RP)-high-performance liquid chromatography technique for the simultaneous determination of OLA and SAM has been developed and validated. Materials and methods The chromatographic analysis was performed using an isocratic mobile phase of 0.1% formic acid in water : methanol : acetonitrile (10 : 40 : 50, v/v) at a flow rate of 0.8 ml/min, and the eluents were monitored at an isosbestic point of 285 nm. Results and conclusion The suggested method's specificity, precision, accuracy, linearity, and robustness were all validated according as per International Conference on Harmonization guidelines. The method's stability was validated by forced degradation experiments. Retention times for OLA and SAM were 2.85 and 4.79 min, respectively. The method was found to be precise and accurate. SAM linearity was found to be between 14.0 and 45.0 mu g/ml, whereas OLA linearity was found to be between 22.5 and 67.5 mu g/ml. The limit of detection (LOD) and limit of quantification (LOQ) of OLA were 2.65 and 8.85 mu g/ml, respectively, whereas the LOD and LOQ of SAM were 8.12 and 27.06 mu g/ml, respectively. As a result, the suggested high-performance liquid chromatography method for the quantification of OLA and SAM was reliable, repeatable, accurate, and sensitive.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [31] Stability-indicating ultra performance liquid chromatography method development and validation for simultaneous estimation of metformin, linagliptin, and empagliflozin in bulk and pharmaceutical dosage form
    Vankalapati, Krishna Rao
    Alegete, Pallavi
    Boodida, Sathyanarayana
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (04)
  • [32] Development and validation of a stability indicating RP-TLC/densitometric method for determination of Loratadine in bulk and in tablets
    Chavhan, Manish L.
    Shirkhedkar, Atul A.
    Surana, Sanjay J.
    ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 : S825 - S830
  • [33] STABILITY INDICATING RP - HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF AMLODIPINE AND CHLORTHALIDONE IN BULK AND TABLET DOSAGE FORM
    Sakpal, P. H.
    Chabukswar, A. R.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (05): : 2161 - 2168
  • [34] Development and Validation of a Stability-Indicating Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Identification, Assay, and Estimation of Related Substances of Ivermectin Drug Substance
    Wimalasinghe, Rasangi M.
    Zhao, Daoli
    Wang, Lin
    Rustum, Abu
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (06) : 1505 - 1513
  • [35] STABILITY-INDICATING REVERSED-PHASE HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY/DENSITOMETRY ESTIMATION OF LAFUTIDINE IN BULK AND TABLETS
    Prajapati, Nitin D.
    Shirkhedkar, Atul A.
    Surana, Sanjay J.
    CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2013, 19 (02) : 213 - 219
  • [36] Development and validation of a stability indicating method for the enantioselective estimation of omeprazole enantiomers in the enteric-coated formulations by high-performance liquid chromatography
    Vyas, Samir
    Patel, Ajay
    Ladva, Kartik D.
    Joshi, H. S.
    Bapodra, Atul H.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2011, 3 (02): : 310 - 314
  • [37] STABILITY INDICATING METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF DAUNORUBICIN AND CYTARABINE IN BULK AND PHARMACEUTICAL DOSAGE FORM BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY
    Goud, Mohan, V
    Roja, Y.
    Sharma, J. V. C.
    Gupta, A. V. S. S. S.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, : 752 - 756
  • [38] STABILITY INDICATING METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF ERTUGLIFLOZIN AND METFORMIN IN BULK AND PHARMACEUTICAL DOSAGE FORM BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY
    Goud, V. Mohan
    Swapna, G.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (01): : 173 - 178
  • [39] STABILITY INDICATING METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF DAUNORUBICIN AND CYTARABINE IN BULK AND PHARMACEUTICAL DOSAGE FORM BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY
    Goud, Mohan, V
    Roja, Y.
    Sharma, J. V. C.
    Gupta, A. V. S. S. S.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, : 58 - 62
  • [40] Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms
    Ahmad, Sufiyan Ahmad Raees
    Patil, Lalit
    Usman, Mohammed Rageeb Mohammed
    Imran, Mohammad
    Akhtar, Rashid
    PHARMACOGNOSY RESEARCH, 2018, 10 (01): : 92 - 97