Stability indicating reverse phase (RP)-high-performance liquid chromatography method development and validation for the simultaneous estimation of olanzapine and samidorphan in bulk and tablets

被引:3
|
作者
Kumar, Hathibelagal Mundarinti [1 ,2 ,4 ,5 ]
Chandrasekhar, Kothapalli [3 ]
机构
[1] Jawaharlal Nehru Technol Univ, Dept Pharmaceut Sci, Anantapur, India
[2] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool, India
[3] Krishna Univ, Dept Chem, Machilipatnam, Andhra Pradesh, India
[4] Jawaharlal Nehru Technol Univ Anantapur, Ananthapuramu & Dept Pharm, Sri G Pullareddy Govt Polytech, BThandrapadu, Kurnool 518007, Andhra Pradesh, India
[5] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool 518007, Andhra Pradesh, India
关键词
high-performance liquid chromatography method; olanzapine; samidorphan; stability indicating and validation; PROCESS-RELATED IMPURITIES; SCHIZOPHRENIA; FLUOXETINE; HPLC; SPECTROPHOTOMETRY; BIOEQUIVALENCE; FORMULATIONS;
D O I
10.4103/epj.epj_64_21
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background Patients with schizophrenia are given a combination tablet combining olanzapine (OLA), an atypical antipsychotic and samidorphan (SAM), an opioid receptor antagonist. Objectives In bulk and tablet dosage forms, a stability-indicating reverse phase (RP)-high-performance liquid chromatography technique for the simultaneous determination of OLA and SAM has been developed and validated. Materials and methods The chromatographic analysis was performed using an isocratic mobile phase of 0.1% formic acid in water : methanol : acetonitrile (10 : 40 : 50, v/v) at a flow rate of 0.8 ml/min, and the eluents were monitored at an isosbestic point of 285 nm. Results and conclusion The suggested method's specificity, precision, accuracy, linearity, and robustness were all validated according as per International Conference on Harmonization guidelines. The method's stability was validated by forced degradation experiments. Retention times for OLA and SAM were 2.85 and 4.79 min, respectively. The method was found to be precise and accurate. SAM linearity was found to be between 14.0 and 45.0 mu g/ml, whereas OLA linearity was found to be between 22.5 and 67.5 mu g/ml. The limit of detection (LOD) and limit of quantification (LOQ) of OLA were 2.65 and 8.85 mu g/ml, respectively, whereas the LOD and LOQ of SAM were 8.12 and 27.06 mu g/ml, respectively. As a result, the suggested high-performance liquid chromatography method for the quantification of OLA and SAM was reliable, repeatable, accurate, and sensitive.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [21] STABILITY INDICATING METHOD DEVELOPMENT AND VALIDATION OF SIMULTANEOUS ESTIMATION OF DOMPERIDONE AND NAPROXEN IN BULK AND TABLET DOSAGE BY RP HPLC
    Tarannum, Adeeba
    Rizwan, S. H.
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (11): : 11718 - 11727
  • [22] Stability Indicating Analytical Method Development and Validation for the Estimation of Rimegepant in Bulk and Its Tablets Using Rp-HPLC
    Kumar, H. M. Sudheer
    Chandrasekhar, Kothapalli Bannoth
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (04) : 41 - 49
  • [23] New Validated Stability-Indicating Reverse-phase High-performance Liquid Chromatography Method for the Simultaneous Estimation of Prazosin and Polythiazide in their Formulations in Human Plasma
    Dharmamoorthy, G.
    Nataraj, K. S.
    Pawar, A. Krishna Manjari
    ASIAN JOURNAL OF PHARMACEUTICS, 2020, 14 (02) : 252 - 264
  • [24] Development and Validation of an UV-Spectrophotometric and Reverse-Phase High-Performance Liquid Chromatography Method for the Estimation of Umifenovir in Bulk and Tablet Formulations
    Somkuwar, Komal
    Sabale, Prafulla
    Sawale, Vaibhav
    Rahangdale, Priya
    JOURNAL OF APPLIED SPECTROSCOPY, 2024, 91 (04) : 884 - 892
  • [25] Development and Validation of Stability-Indicating High-Performance Thin-Layer Chromatography Method for Estimation of Repaglinide in Bulk and in Pharmaceutical Formulation
    Jain, P. S.
    Patel, M. K.
    Surana, S. J.
    ACTA CHROMATOGRAPHICA, 2013, 25 (03) : 531 - 544
  • [26] Development and validation of a stability-indicating analytical method for simultaneous determination of sodium phenylbutyrate and taurursodiol in bulk and formulation using reverse phase ultra-performance liquid chromatography
    Beludari, Mahammad I.
    Chedela, Hari K.
    Lingareddy, Siva S. R.
    Dara, China B.
    Karimulla, Shaik
    EGYPTIAN PHARMACEUTICAL JOURNAL, 2024, 23 (02) : 264 - 271
  • [27] STABILITY INDICATING RP-HPLC ASSAY METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BALOFLOXACIN IN TABLETS
    Bhavani, G.
    Hussain, S. S.
    Prasanna, S. Laxmi
    Kumar, A. Ashok
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 2 (10): : 1371 - 1381
  • [28] Development and Validation of a New Stability Indicating RP-UFLC Method for the Estimation of Ranolazine Tablets
    Aluri, Sai Gnaneswari
    Annapurna, Mukthinuthalapati Mathrusri
    ASIAN JOURNAL OF PHARMACEUTICS, 2021, 15 (04) : 488 - 497
  • [29] Development and validation of stability-indicating RP-HPLC method for estimation of pamabrom in tablets
    Shah, U.
    Kavad, M.
    Raval, M.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 76 (03) : 198 - 202
  • [30] A Novel Reverse Phase High-Performance Liquid Chromatography (RP-HPLC-UV) Method for the Estimation of Alosetron HCl and Its Validation
    Karthik, Y.
    Babu, B.
    Meyyanathan, S. N.
    Awari, Vishal P.
    Krishnaveni, N.
    ACTA CHROMATOGRAPHICA, 2015, 27 (02) : 321 - 330