Stability indicating reverse phase (RP)-high-performance liquid chromatography method development and validation for the simultaneous estimation of olanzapine and samidorphan in bulk and tablets

被引:3
|
作者
Kumar, Hathibelagal Mundarinti [1 ,2 ,4 ,5 ]
Chandrasekhar, Kothapalli [3 ]
机构
[1] Jawaharlal Nehru Technol Univ, Dept Pharmaceut Sci, Anantapur, India
[2] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool, India
[3] Krishna Univ, Dept Chem, Machilipatnam, Andhra Pradesh, India
[4] Jawaharlal Nehru Technol Univ Anantapur, Ananthapuramu & Dept Pharm, Sri G Pullareddy Govt Polytech, BThandrapadu, Kurnool 518007, Andhra Pradesh, India
[5] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool 518007, Andhra Pradesh, India
关键词
high-performance liquid chromatography method; olanzapine; samidorphan; stability indicating and validation; PROCESS-RELATED IMPURITIES; SCHIZOPHRENIA; FLUOXETINE; HPLC; SPECTROPHOTOMETRY; BIOEQUIVALENCE; FORMULATIONS;
D O I
10.4103/epj.epj_64_21
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background Patients with schizophrenia are given a combination tablet combining olanzapine (OLA), an atypical antipsychotic and samidorphan (SAM), an opioid receptor antagonist. Objectives In bulk and tablet dosage forms, a stability-indicating reverse phase (RP)-high-performance liquid chromatography technique for the simultaneous determination of OLA and SAM has been developed and validated. Materials and methods The chromatographic analysis was performed using an isocratic mobile phase of 0.1% formic acid in water : methanol : acetonitrile (10 : 40 : 50, v/v) at a flow rate of 0.8 ml/min, and the eluents were monitored at an isosbestic point of 285 nm. Results and conclusion The suggested method's specificity, precision, accuracy, linearity, and robustness were all validated according as per International Conference on Harmonization guidelines. The method's stability was validated by forced degradation experiments. Retention times for OLA and SAM were 2.85 and 4.79 min, respectively. The method was found to be precise and accurate. SAM linearity was found to be between 14.0 and 45.0 mu g/ml, whereas OLA linearity was found to be between 22.5 and 67.5 mu g/ml. The limit of detection (LOD) and limit of quantification (LOQ) of OLA were 2.65 and 8.85 mu g/ml, respectively, whereas the LOD and LOQ of SAM were 8.12 and 27.06 mu g/ml, respectively. As a result, the suggested high-performance liquid chromatography method for the quantification of OLA and SAM was reliable, repeatable, accurate, and sensitive.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [1] Development and Validation of Stability Indicating Method for the Determination of Exemestane by Reverse Phase High Performance Liquid Chromatography
    Konda, Bharath
    Tiwari, Ravi N.
    Fegade, Harshal
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (08) : 634 - 639
  • [2] Development and Validation of Reverse-Phase High-Performance Liquid Chromatography Method for Simultaneous Estimation of Doxorubicin and Clotrimazole
    Sharma, Priyanka
    Kapoor, Bhupinder
    Hussain, Md Sadique
    Singh, Gurvinder
    Rani, Pooja
    Saini, Balraj
    Wadhwa, Pankaj
    Kumar, Rajesh
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2024, 22 (02) : 86 - 96
  • [3] Stability Indicating Reverse Phase-High Performance Liquid Chromatography Method for Simultaneous Estimation of Cabotegravir and Rilpivirine
    Vemuluri, Padmabhushana Chary
    Dodda, Sireesha
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2023, 57 (03) : S766 - S771
  • [4] A stability indicating novel analytical method for the determination of lamivudine and dolutegravir in bulk and its tablets using reverse phase high-performance liquid chromatography
    Lalitha, K., V
    Reddy, J. Raveendra
    Nayakanti, Devanna
    ASIAN JOURNAL OF PHARMACEUTICAL RESEARCH AND HEALTH CARE, 2022, 14 (04) : 209 - 215
  • [5] Method Development and Validation for the Simultaneous Estimation of Rosuvastatin and Amlodipine in Bulk and its Formulation using Reverse-Phase High-Performance Liquid Chromatography
    Boggula, Narender
    Mulagada, Gowri Manoja
    Priya, D. K. Shanthi
    Bakshi, Vasudha
    Peddapalli, Himabindu
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (04) : S1304 - S1309
  • [6] Stability Indicating Reversed-phase High-Performance Liquid Chromatography Method Development and Validation for Simultaneous Estimation of Bismuth Subcitrate, Tetracycline, and Metronidazole in Bulk and Capsule Dosage Form
    Prathap, B.
    Gobinath, M.
    Haribaskar, V
    Kumar, B.
    Kavitha, M.
    Harika, S.
    Bhavya, C.
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (04) : S1310 - S1319
  • [7] Development and Validation of Stability-Indicating High-Performance Liquid Chromatography Method for Estimation of Lacosamide in Bulk and Its Pharmaceutical Dosage Form
    Padhiyar, Shantilal
    Jivani, Kamlesh M.
    Upadhyay, Jagat
    Patel, Tejas
    Suhagia, Bhanubhai
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023, 61 (10) : 943 - 952
  • [8] Implementation of Quality by Design Methodology in Development and Validation of a New Stability-Indicating, Reverse Phase High-Performance Liquid Chromatography Method for the Rapid Estimation of Piribedil in Piribedil Prolonged Release Tablets
    Kumar, N.
    Sangeetha, D.
    Reddy, S. J.
    Kalayanaraman, L.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 84 (01) : 207 - 218
  • [9] Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form
    Maradiya, H. K.
    Pansara, Vasundhara H.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2013, 75 (02) : 238 - U158
  • [10] QUANTITATION OF CHLORPROPAMIDE AND TOLBUTAMIDE IN TABLETS BY STABILITY-INDICATING REVERSE PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DASGUPTA, V
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1984, 17 (NB18): : 2119 - 2128