An Efficient Algorithm Based on Spectrum Migration for High Frame Rate Ultrasound Imaging

被引:2
|
作者
Feng, Shuai [1 ]
Jin, Liu [1 ]
Wang, Yadan [1 ]
Zhao, Wei [1 ,2 ]
Peng, Hu [1 ]
Qiao, Heyuan [1 ]
机构
[1] Hefei Univ Technol, Dept Biomed Engn, Hefei 230009, Peoples R China
[2] Yijishan Hosp, Wannan Med Coll, Wuhu 241001, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
High frame rate imaging; spectrum migration; Fourier migration; DIFFRACTION; SYSTEM; FIELDS;
D O I
10.32604/cmes.2021.014027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The high frame rate (HFR) imaging technique requires only one emission event for imaging. Therefore, it can achieve ultrafast imaging with frame rates up to the kHz regime, which satisfies the frame rate requirements for imaging moving tissues in scientific research and clinics. Lu's Fourier migration method is based on a non diffraction beam to obtain HFR images and can improve computational speed and efficiency. However, in order to obtain high-quality images, Fourier migration needs to make full use of the spectrum of echo signals for imaging, which requires a large number of Fast Fourier Transform (FFT) points and increases the complexity of the hardware when the echo frequency is high. Here, an efficient algorithm using the spectrum migration technique based on the spectrum's distribution characteristics is proposed to improve the imaging efficiency in HFR imaging. Since the actual echo signal spectrum is of limited bandwidth, low-frequency and high-frequency parts with low-energy have little contribution to the imaging spectrum. We transform the effective part that provides the main energy in the signal spectrum to the imaging spectrum while the ineffective spectrum components are not utilized for imaging. This can significantly reduce the number of Fourier transform points, improve Fourier imaging efficiency, and ensure the imaging quality. The proposed method is evaluated on simulated and experimental datasets. Results demonstrated that the proposed method could achieve equivalent image quality with a reduced point number for FFT compared to the complete spectrum migration. In this paper, it only requires a quarter of the FFT points used in the complete spectrum migration, which can improve the computational efficiency; thus, it is more suitable for real-time data processing. The proposed spectrum migration method has a specific significance for the study and clinical application of HFR imaging.
引用
收藏
页码:739 / 754
页数:16
相关论文
共 50 条
  • [31] High-Frame-Rate Coherence Imaging of the Heart with Ultrasound Diverging Waves
    Matrone, Giulia
    Spairani, Edoardo
    Matrone, Benedetta
    Ramalli, Alessandro
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [32] Elasticity Imaging using conventional and high-frame rate ultrasound imaging: Experimental study
    Park, Suhyun
    Aglyamov, Salavat R.
    Emelianov, Stanislav Y.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (11) : 2246 - 2256
  • [33] High-frequency high frame rate ultrasound Imaging system for small animal Imaging with linear Arrays
    Xu, XC
    Hu, CH
    Sun, L
    Yen, J
    Shung, KK
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1431 - 1434
  • [34] Design of a digital high frequency linear array ultrasound imaging system with high frame rate
    Hu, Chang-Hong
    Shung, K. Kirk
    Chang, Allan
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1529 - +
  • [35] A novel envelope detector for high-frame rate, high-frequency ultrasound imaging
    Chang, Jin Ho
    Yen, Jesse T.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (09) : 1792 - 1801
  • [36] High frame rate ultrasound coded excitation
    Ji, Cao
    Liangmong, Koh
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1842 - 1845
  • [37] Architecture of an Ultrasound System for Continuous Real-Time High Frame Rate Imaging
    Boni, Enrico
    Bassi, Luca
    Dallai, Alessandro
    Meacci, Valentino
    Ramalli, Alessandro
    Scaringella, Monica
    Guidi, Francesco
    Ricci, Stefano
    Tortoli, Piero
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (09) : 1276 - 1284
  • [38] Coded excitation waveform engineering for high frame rate synthetic aperture ultrasound imaging
    Lashkari, Bahman
    Zhang, Kaicheng
    Dovlo, Edem
    Mandelis, Andreas
    ULTRASONICS, 2017, 77 : 121 - 132
  • [39] Detection of mechanical activation of the left ventricle using high frame rate ultrasound imaging
    Kvaale, K.
    Bersvendsen, J.
    Salles, S.
    Aalen, J.
    Remme, E.
    Brekke, P.
    Edvardsen, T.
    Samset, E.
    EUROPEAN HEART JOURNAL, 2018, 39 : 282 - 282
  • [40] Cardiac imaging with high frame rate contrast enhanced ultrasound: in-vivo demonstration
    Toulemonde, M.
    Li, Y.
    Lin, S.
    Tang, M. X.
    Butler, M.
    Sboros, V.
    Eckersley, R.
    Duncan, W. C.
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,