Reproducibility of scanning laser Doppler flowmetry in the rat retina and optic nervehead

被引:7
|
作者
Tsujikawa, A
Kiryu, J [1 ]
Nonaka, A
Yamashiro, K
Ogura, Y
Honda, Y
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Nagoya City Univ, Sch Med, Dept Ophthalmol, Nagoya, Aichi 467, Japan
关键词
blood flow; rat; retina; scanning laser Doppler flowmeter;
D O I
10.1016/S0021-5155(99)00226-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study is to confirm the reliability of scanning laser Doppler flowmetry in the rat retina and optic nervehead, and the validity of measuring changes of retinal blood flow in rats while: breathing 100% oxygen. Methods: We used a commercially available scanning laser Doppler flowmeter. To ascertain reliability, five consecutive and separate perfusion measurements of 12 eyes of 12 anesthetized pigmented rats were performed. To evaluate the validity of the system, repeated measurements were taken in anesthetized rats breathing room air or 100% oxygen. This series of measurements was repeated three times. Results: The reliability coefficients of volume, flow, and velocity in the optic nervehead and the retina ranged from 0.80 to 0.83 and 0.77 to 0.82, respectively. After the first exposure to oxygen, the measured values of volume, flow, and velocity were reduced by an average of 20.9-24.0%, 21.2-28.2%, and 19.5-24.5%, respectively. After the values returned to the basal condition, the second and third exposures to oxygen yielded measured values that were reduced by the same amounts as at the first exposure. Conclusions: Scanning laser Doppler flowmetry provided relatively good reliability in measurements of blood flow in the rat retina and optic nervehead. This study has indicated the possibility of applying this system to the rat retina. Jpn J Ophthalmol 2000;44:257-262 (C) 2000 Japanese Ophthalmological Society.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [41] Impact of simulated light scatter on scanning laser Doppler flowmetry
    Venkataraman, ST
    Hudson, C
    Harvey, E
    Flanagan, JG
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (09) : 1192 - 1195
  • [42] Functional imaging of the retinal microvasculature by Scanning Laser Doppler Flowmetry
    Michelson G.
    Welzenbach J.
    Pal I.
    Harazny J.
    International Ophthalmology, 2001, 23 (4-6) : 327 - 335
  • [43] Temperature Influence on Scanning Laser Doppler Flowmetry in Anesthetized Mice
    Fahy, Evan J.
    Lavin, Christopher V.
    Abbas, Darren
    Griffin, Michelle
    King, Megan E.
    Longaker, Michael T.
    Wan, Derrick C.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2021, 233 (05) : E157 - E157
  • [44] Optic disc morphometry correlated with confocal laser scanning Doppler Flowmetry measurements in normal-pressure glaucoma
    Jonas, JB
    Harazny, J
    Budde, WM
    Mardin, CY
    Papastathopoulos, KI
    Michelson, G
    JOURNAL OF GLAUCOMA, 2003, 12 (03) : 260 - 265
  • [45] Blood flow measurements of optic nerve head rim tissue as a function of illumination with scanning laser Doppler flowmetry
    Embleton, SJ
    Hosking, SL
    Pettinger, C
    Kagemann, L
    Chabra, A
    Chung, HS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S276 - S276
  • [46] LASER DOPPLER FLOWMETRY IN SUBCUTANEOUS RAT-TUMORS
    VAUPEL, P
    KLUGE, M
    DIAZ, MJ
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1987, 6 (01): : 91 - 91
  • [47] Basic technique and anatomically imposed limitations of confocal scanning laser Doppler flowmetry at the optic nerve head level
    Sehi, Mitra
    ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E1 - E11
  • [48] LASER DOPPLER FLOWMETRY
    不详
    FASEB JOURNAL, 1993, 7 (04): : A875 - A875
  • [49] Effect of senescence on ocular blood flow in the retina, neuroretinal rim and lamina cribrosa, using scanning laser Doppler flowmetry
    Embleton, SJ
    Hosking, SL
    Hilton, EJR
    Cunliffe, IA
    EYE, 2002, 16 (02) : 156 - 162
  • [50] Effect of senescence on ocular blood flow in the retina, neuroretinal rim and lamina cribrosa, using scanning laser Doppler flowmetry
    S J Embleton
    S L Hosking
    E J Roff Hilton
    I A Cunliffe
    Eye, 2002, 16 (2) : 156 - 162