Reproducibility of scanning laser Doppler flowmetry in the rat retina and optic nervehead

被引:7
|
作者
Tsujikawa, A
Kiryu, J [1 ]
Nonaka, A
Yamashiro, K
Ogura, Y
Honda, Y
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Nagoya City Univ, Sch Med, Dept Ophthalmol, Nagoya, Aichi 467, Japan
关键词
blood flow; rat; retina; scanning laser Doppler flowmeter;
D O I
10.1016/S0021-5155(99)00226-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study is to confirm the reliability of scanning laser Doppler flowmetry in the rat retina and optic nervehead, and the validity of measuring changes of retinal blood flow in rats while: breathing 100% oxygen. Methods: We used a commercially available scanning laser Doppler flowmeter. To ascertain reliability, five consecutive and separate perfusion measurements of 12 eyes of 12 anesthetized pigmented rats were performed. To evaluate the validity of the system, repeated measurements were taken in anesthetized rats breathing room air or 100% oxygen. This series of measurements was repeated three times. Results: The reliability coefficients of volume, flow, and velocity in the optic nervehead and the retina ranged from 0.80 to 0.83 and 0.77 to 0.82, respectively. After the first exposure to oxygen, the measured values of volume, flow, and velocity were reduced by an average of 20.9-24.0%, 21.2-28.2%, and 19.5-24.5%, respectively. After the values returned to the basal condition, the second and third exposures to oxygen yielded measured values that were reduced by the same amounts as at the first exposure. Conclusions: Scanning laser Doppler flowmetry provided relatively good reliability in measurements of blood flow in the rat retina and optic nervehead. This study has indicated the possibility of applying this system to the rat retina. Jpn J Ophthalmol 2000;44:257-262 (C) 2000 Japanese Ophthalmological Society.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [21] Evaluation of a new scanning laser Doppler flowmetry in comparison to a fundus camera-based laser Doppler flowmetry
    Okamoto, N
    Harino, S
    Suzuki, M
    Kitanishi, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2803 - 2803
  • [22] Laser Doppler flowmetry of the optic nerve head in glaucoma
    Piltz-Seymour, JR
    SURVEY OF OPHTHALMOLOGY, 1999, 43 : S191 - S198
  • [23] SCANNING LASER DOPPLER FLOWMETRY OF NON PERFUSED REGIONS OF THE OPTIC NERVE HEAD IN GLAUCOMATOUS PATIENTS
    G.J.Ben Simon
    I.Moroz
    M.Goldenfeld
    S.Melamed
    国际眼科杂志, 2003, (01) : 15 - 15
  • [24] Reproducibility and Effect of Sampling Depth on Laser Doppler Flowmetry on Laser Doppler Flowmetry Measures During the Reflex Cutaneous Vasoconstriction Response
    Theis, Emma
    Schwartz, Kelsey
    Bunting, Kearsten
    McCaughey, Rebecca
    Lang, James
    FASEB JOURNAL, 2021, 35
  • [25] Optic nerve head blood flow using scanning laser Doppler flowmetry after laser in situ keratomileusis
    Ozdamar, A
    Ocakoglu, O
    JOURNAL OF REFRACTIVE SURGERY, 2003, 19 (04) : 433 - 437
  • [26] Principle, validity, and reliability of scanning laser Doppler flowmetry
    Michelson, G
    Schmauss, B
    Langhans, MJ
    Harazny, J
    Groh, MJM
    JOURNAL OF GLAUCOMA, 1996, 5 (02) : 99 - 105
  • [27] Confocal scanning laser Doppler flowmetry in retinovascular disease
    Gibson, JM
    EYE, 2001, 15 (3) : 259 - 260
  • [28] Confocal scanning laser Doppler flowmetry in retinovascular disease
    J M Gibson
    Eye, 2001, 15 : 259 - 260
  • [29] Light scatter and scanning laser Doppler flowmetry assessment
    Venkataraman, ST
    Hudson, C
    Harvey, E
    Flanagan, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [30] The influence of ocular pulsatility on scanning laser Doppler flowmetry
    Sullivan, P
    Cioffi, GA
    Wang, L
    Johnson, CA
    Van Buskirk, EM
    Sherman, KR
    Bacon, DR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (01) : 81 - 87