Reproducibility of scanning laser Doppler flowmetry in the rat retina and optic nervehead

被引:7
|
作者
Tsujikawa, A
Kiryu, J [1 ]
Nonaka, A
Yamashiro, K
Ogura, Y
Honda, Y
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Nagoya City Univ, Sch Med, Dept Ophthalmol, Nagoya, Aichi 467, Japan
关键词
blood flow; rat; retina; scanning laser Doppler flowmeter;
D O I
10.1016/S0021-5155(99)00226-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study is to confirm the reliability of scanning laser Doppler flowmetry in the rat retina and optic nervehead, and the validity of measuring changes of retinal blood flow in rats while: breathing 100% oxygen. Methods: We used a commercially available scanning laser Doppler flowmeter. To ascertain reliability, five consecutive and separate perfusion measurements of 12 eyes of 12 anesthetized pigmented rats were performed. To evaluate the validity of the system, repeated measurements were taken in anesthetized rats breathing room air or 100% oxygen. This series of measurements was repeated three times. Results: The reliability coefficients of volume, flow, and velocity in the optic nervehead and the retina ranged from 0.80 to 0.83 and 0.77 to 0.82, respectively. After the first exposure to oxygen, the measured values of volume, flow, and velocity were reduced by an average of 20.9-24.0%, 21.2-28.2%, and 19.5-24.5%, respectively. After the values returned to the basal condition, the second and third exposures to oxygen yielded measured values that were reduced by the same amounts as at the first exposure. Conclusions: Scanning laser Doppler flowmetry provided relatively good reliability in measurements of blood flow in the rat retina and optic nervehead. This study has indicated the possibility of applying this system to the rat retina. Jpn J Ophthalmol 2000;44:257-262 (C) 2000 Japanese Ophthalmological Society.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [1] Confocal scanning laser ophthalmoscopy and Doppler flowmetry of the rat retina
    Chauhan, BC
    Yu, DY
    Cringle, SJ
    Carlsson, AM
    Su, EN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1273 - 1273
  • [2] Reproducibility of retinal and optic nerve head blood flow measurements with scanning laser Doppler flowmetry
    Nicolela, MT
    Hnik, P
    Schulzer, M
    Drance, SM
    JOURNAL OF GLAUCOMA, 1997, 6 (03) : 157 - 164
  • [3] Reproducibility of retinal and optic nerve head perfusion measurements using scanning laser Doppler flowmetry
    Hafez, AS
    Bizzarro, RLG
    Rivard, M
    Trabut, I
    Lovasik, JV
    Kergoat, H
    Lesk, MR
    OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (05): : 422 - 432
  • [4] Reproducibility of laser Doppler flowmetry in the human optic nerve head
    Joos, KM
    Pillunat, LE
    Knighton, RW
    Anderson, DR
    Feuer, WJ
    JOURNAL OF GLAUCOMA, 1997, 6 (04) : 212 - 216
  • [5] Penetration depth of scanning laser Doppler flowmetry and laser Doppler flowmetry in the human optic nerve head
    Böhm, AG
    Kuba, GB
    Pillunat, LE
    Richard, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S779 - S779
  • [6] Reproducibility of retinal and optic nerve head perfusion measurements using scanning laser Doppler flowmetry.
    Bizzarro, RLG
    Hafez, AS
    Rivard, M
    Trabut, I
    Lesk, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S556 - S556
  • [7] Confocal scanning of the optic laser Doppler flowmetry nerve in smokers
    Erb, C
    Orgül, S
    Griesser, S
    Lietz, A
    Hendrickson, P
    Flammer, J
    NEURO-OPHTHALMOLOGY, 1999, 21 (01) : 33 - 37
  • [8] Capillary flow of the peripapillary retina and the optic nerve head using confocal scanning laser doppler flowmetry (Heidelberg retina flowmeter)
    Yamana, Y
    Matsuo, M
    Yamana, T
    6TH WORLD CONGRESS FOR MICROCIRCULATION, 1996, : 289 - 294
  • [9] Confocal scanning laser Doppler flowmetry in the rat retina - Origin of flow signals and dependence on scan depth
    Chauhan, BC
    Yu, PK
    Cringle, SJ
    Yu, DY
    ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (03) : 397 - 402
  • [10] Depth of penetration of scanning laser Doppler flowmetry in the primate optic nerve
    Wang, L
    Cull, G
    Cioffi, GA
    ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (12) : 1810 - 1814