Dose-position and dose-volume histogram analysis of standard wedged and intensity modulated treatments in breast radiotherapy

被引:47
|
作者
Donovan, EM
Bleackley, NJ
Evans, PM
Reise, SF
Yarnold, JR
机构
[1] Royal Marsden NHS Trust, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Dept Radiotherapy, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5PT, Surrey, England
来源
BRITISH JOURNAL OF RADIOLOGY | 2002年 / 75卷 / 900期
关键词
D O I
10.1259/bjr.75.900.750967
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this work was to evaluate the positional distribution of dose in a concise manner and to analyse dose-histogram results in tangential breast radiotherapy in 300 patients, randomized to standard wedged or intensity modulated radiotherapy (IMRT), for future correlation with clinical outcome data. A simple method for analysing the dose-position relationship in the treatment volume was used to compare the spatial distribution of dose in patients. The breast was divided into equal thirds (upper, middle and lower) and dose was assessed using three dose bands; 95-105%, > 105-110% and >110% of the prescription dose. The effect of using IMRT on the dosimetry was assessed from dose-volume histogram data using the following parameters: percentage of the target volume receiving a dose less than 95%, greater than 105%, either less than 95% or greater than 105% of that prescribed; the mean dose; and the maximum dose. Doses greater than 105% were predominantly in the upper and lower regions of the breast in the standard wedged treatment. 96% of these patients received doses greater than 105% in the upper region of the breast and 70% received doses greater than 105% in the lower breast. Only 4% of patients allocated IMRT received doses greater than 105% in either region. Analysis of dose-volume histogram data showed that IMRT reduced the volume receiving a dose greater than 105% by a mean of 10.7% (p=<0.001); the mean change in the volume receiving a dose less than 95% was 0.2% (p=0.63). Average mean plan dose was 101.6% for standard treatment and 99.6% for IMRT (p<0.001 for each compared with 100.0% ideal). The mean value of maximum dose was reduced from 111% to 106% in the group of patients randomized to IMRT. A simple method for describing the relationship between dose and position in the breast, which is helpful for the effective correlation of dosimetry and clinical effects, is reported. Further, application of IMRT to the tangential field irradiation of the breast has been demonstrated to reduce high dose regions in both volume and dose level without compromising either minimum dose coverage or mean dose delivered to the breast.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 50 条
  • [41] Comparison of rectal dose-wall histogram versus dose-volume histogram for modeling the incidence of late rectal bleeding after radiotherapy
    Tucker, SL
    Dong, L
    Cheung, R
    Johnson, J
    Mohan, R
    Huang, EH
    Liu, HH
    Thames, HD
    Kuban, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (05): : 1589 - 1601
  • [42] Effect of RTOG breast/chest wall guidelines on dose-volume histogram parameters
    Rudra, Sonali
    Al-Hallaq, Hania A.
    Feng, Christine
    Chmura, Steven J.
    Hasan, Yasmin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (02): : 127 - 137
  • [43] DOSE-VOLUME HISTOGRAM ANALYSIS OF TECHNIQUES FOR IRRADIATING PITUITARY-ADENOMAS
    SOHN, JW
    DALZELL, JG
    SUH, JH
    TEFFT, M
    SCHELL, MC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (03): : 831 - 837
  • [44] Dose-volume histogram analysis of high dose rate intracavitary brachytherapy for uterine cervix cancer
    Terahara, A
    Nakano, T
    Ishikawa, A
    Morita, S
    Tsujii, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (03): : 549 - 554
  • [45] A new homogeneity index based on statistical analysis of the dose-volume histogram
    Yoon, Myonggeun
    Park, Sung Yong
    Shin, Dongho
    Lee, Se Byeong
    Pyo, Hong Ryull
    Kim, Dae Yong
    Cho, Kwan Ho
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 9 - 17
  • [47] Intensity modulated radiotherapy for localized prostate cancer: rigid compliance to dose-volume constraints as a warranty of acceptable toxicity?
    Michael J Chen
    Eduardo Weltman
    Rodrigo M Hanriot
    Fábio P Luz
    Paulo J Cecílio
    José C da Cruz
    Frederico R Moreira
    Adriana S Santos
    Lidiane C Martins
    Wladmir Nadalin
    Radiation Oncology, 2
  • [48] Dose-volume Histogram Analysis of Knowledge-based Volumetric-modulated Arc Therapy Planning in Postoperative Breast Cancer Irradiation
    Inoue, Eri
    Doi, Hiroshi
    Monzen, Hajime
    Tamura, Mikoto
    Inada, Masahiro
    Ishikawa, Kazuki
    Nakamatsu, Kiyoshi
    Nishimura, Yasumasa
    IN VIVO, 2020, 34 (03): : 1095 - 1101
  • [49] Feasibility of hippocampal dose-volume parameters associated with memory decline in intensity-modulated radiotherapy for supratentorial tumors
    Takahashi, Shigeo
    Anada, Masahide
    Kinoshita, Toshifumi
    Nishide, Takamasa
    Kozai, Shohei
    Shibata, Toru
    MOLECULAR AND CLINICAL ONCOLOGY, 2021, 14 (03)
  • [50] Intensity modulated radiotherapy for localized prostate cancer: rigid compliance to dose-volume constraints as a warranty of acceptable toxicity?
    Chen, Michael J.
    Weltman, Eduardo
    Hanriot, Rodrigo M.
    Luz, Fabio P.
    Cecilio, Paulo J.
    da Cruz, Jose C.
    Moreira, Frederico R.
    Santos, Adriana S.
    Martins, Lidiane C.
    Nadalin, Wladmir
    RADIATION ONCOLOGY, 2007, 2 (1)