Vertebral Compression Fractures: Third-Generation Dual-Energy CT for Detection of Bone Marrow Edema at Visual and Quantitative Analyses

被引:121
|
作者
Petritsch, Bernhard [1 ]
Kosmala, Aleksander [1 ]
Weng, Andreas M. [1 ]
Krauss, Bernhard [3 ]
Heidemeier, Anke [1 ]
Wagner, Richard [2 ]
Heintel, Timo M. [2 ]
Gassenmaier, Tobias [1 ]
Bley, Thorsten A. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Hosp Wurzburg, Dept Trauma Hand Plast & Reconstruct Surg, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[3] Siemens Healthcare, Imaging & Therapy Div, Forchheim, Germany
关键词
INITIAL-EXPERIENCE; PERCUTANEOUS VERTEBROPLASTY; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; BASIC PRINCIPLES; LESIONS; DIAGNOSIS; IMAGES; DECOMPOSITION; OSTEOPOROSIS;
D O I
10.1148/radiol.2017162165
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the diagnostic performance of a third-generation dual-energy computed tomographic (CT) virtual noncalcium (VNCa) technique for detection of traumatic bone marrow edema in patients with vertebral compression fractures. Materials and Methods: This prospective study was approved by the institutional review board. Informed consent was obtained from all participants. Twenty-two consecutive patients with 37 morphologic vertebral fractures were studied between October 2015 and May 2016. All patients underwent dual- energy CT (90 kV and 150 kV with a tin filter) and 3-T magnetic resonance (MR) imaging. Two independent readers visually evaluated all vertebral bodies (n = 163) for the presence of abnormal bone marrow attenuation on VNCa images by using color-coded maps and performed a quantitative analysis of CT numbers on VNCa images. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values. Results: In the visual analysis, VNCa images had an overall sensitivity of 64.0%, specificity of 99.3%, accuracy of 93.9%, positive predictive value of 94.1%, and negative predictive value of 93.8%. The interobserver agreement was excellent (kappa = 0.85). CT numbers obtained from VNCa images were significantly different in vertebral bodies with and without edema (P <.001). Receiver operating characteristic analysis revealed an area under the curve of 0.922. A cutoff value of 247 provided sensitivity of 92.0%, specificity of 82.6%, accuracy of 84.0%, positive predictive value of 48.9%, and negative predictive value of 98.3% for the differentiation of edematous vertebral bodies. Conclusion: Visual and quantitative analyses of dual-energy VNCa images showed excellent diagnostic performance for assessing traumatic bone marrow edema in vertebral compression fractures. (C) RSNA, 2017
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [31] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Mantovani, William
    Faccioli, Niccolo
    Crivellari, Giacomo
    Romano, Luigi
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2021, 126 (03): : 405 - 413
  • [32] Identification of bone marrow edema of the ankle: diagnostic accuracy of dual-energy CT in comparison with MRI
    Giovanni Foti
    Matteo Catania
    Simone Caia
    Luigi Romano
    Alberto Beltramello
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2019, 124 : 1028 - 1036
  • [33] Comprehensive comparison of dual-energy computed tomography and magnetic resonance imaging for the assessment of bone marrow edema and fracture lines in acute vertebral fractures
    Cavallaro, Marco
    D'Angelo, Tommaso
    Albrecht, Moritz H.
    Yel, Ibrahim
    Martin, Simon S.
    Wichmann, Julian L.
    Lenga, Lukas
    Mazziotti, Silvio
    Blandino, Alfredo
    Ascenti, Giorgio
    Longo, Marcello
    Vogl, Thomas J.
    Booz, Christian
    EUROPEAN RADIOLOGY, 2022, 32 (01) : 561 - 571
  • [34] Comprehensive comparison of dual-energy computed tomography and magnetic resonance imaging for the assessment of bone marrow edema and fracture lines in acute vertebral fractures
    Marco Cavallaro
    Tommaso D’Angelo
    Moritz H. Albrecht
    Ibrahim Yel
    Simon S. Martin
    Julian L. Wichmann
    Lukas Lenga
    Silvio Mazziotti
    Alfredo Blandino
    Giorgio Ascenti
    Marcello Longo
    Thomas J. Vogl
    Christian Booz
    European Radiology, 2022, 32 : 561 - 571
  • [35] Bone marrow edema in traumatic vertebral compression fractures: Diagnostic accuracy of dual-layer detector CT using calcium suppressed images
    Neuhaus, Victor
    Lennartz, Simon
    Abdullayev, Nuran
    Hokamp, Nils Grosse
    Shapira, Nadav
    Kafri, Galit
    Holz, Jasmin A.
    Krug, Barbara
    Hellmich, Martin
    Maintz, David
    Borggrefe, Jan
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 216 - 220
  • [36] ACCURACY OF DUAL-ENERGY COMPUTED TOMOGRAPHY FOR THE DETECTION OF BONE MARROW EDEMA IN PATIENTS WITH AXIAL SPONDYLOARTHRITIS
    Carotti, M.
    Salaffi, F.
    Piccinni, P.
    Di Carlo, M.
    Farah, S.
    Benfaremo, D.
    Luchetti, M. M.
    Giovagnoni, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 493 - 494
  • [37] Extent of bone marrow edema on dual-energy CT aids in differentiation of acute from post-acute fractures of lower legs
    Haider, Shamrez
    Pezeshk, Parham
    Xi, Yin
    Abdellatif, Waleed
    Chhabra, Avneesh
    EUROPEAN RADIOLOGY, 2023, 33 (06) : 4094 - 4102
  • [38] Extent of bone marrow edema on dual-energy CT aids in differentiation of acute from post-acute fractures of lower legs
    Shamrez Haider
    Parham Pezeshk
    Yin Xi
    Waleed Abdellatif
    Avneesh Chhabra
    European Radiology, 2023, 33 : 4094 - 4102
  • [39] Diagnostic accuracy of third-generation dual-source dual-energy CT: a prospective trial and protocol for clinical implementation
    Tim Nestler
    Kai Nestler
    Andreas Neisius
    Hendrik Isbarn
    Christopher Netsch
    Stephan Waldeck
    Hans U. Schmelz
    Christian Ruf
    World Journal of Urology, 2019, 37 : 735 - 741
  • [40] Diagnostic accuracy of third-generation dual-source dual-energy CT: a prospective trial and protocol for clinical implementation
    Nestler, Tim
    Nestler, Kai
    Neisius, Andreas
    Isbarn, Hendrik
    Netsch, Christopher
    Waldeck, Stephan
    Schmelz, Hans U.
    Ruf, Christian
    WORLD JOURNAL OF UROLOGY, 2019, 37 (04) : 735 - 741