Vertebral Compression Fractures: Third-Generation Dual-Energy CT for Detection of Bone Marrow Edema at Visual and Quantitative Analyses

被引:121
|
作者
Petritsch, Bernhard [1 ]
Kosmala, Aleksander [1 ]
Weng, Andreas M. [1 ]
Krauss, Bernhard [3 ]
Heidemeier, Anke [1 ]
Wagner, Richard [2 ]
Heintel, Timo M. [2 ]
Gassenmaier, Tobias [1 ]
Bley, Thorsten A. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Hosp Wurzburg, Dept Trauma Hand Plast & Reconstruct Surg, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[3] Siemens Healthcare, Imaging & Therapy Div, Forchheim, Germany
关键词
INITIAL-EXPERIENCE; PERCUTANEOUS VERTEBROPLASTY; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; BASIC PRINCIPLES; LESIONS; DIAGNOSIS; IMAGES; DECOMPOSITION; OSTEOPOROSIS;
D O I
10.1148/radiol.2017162165
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the diagnostic performance of a third-generation dual-energy computed tomographic (CT) virtual noncalcium (VNCa) technique for detection of traumatic bone marrow edema in patients with vertebral compression fractures. Materials and Methods: This prospective study was approved by the institutional review board. Informed consent was obtained from all participants. Twenty-two consecutive patients with 37 morphologic vertebral fractures were studied between October 2015 and May 2016. All patients underwent dual- energy CT (90 kV and 150 kV with a tin filter) and 3-T magnetic resonance (MR) imaging. Two independent readers visually evaluated all vertebral bodies (n = 163) for the presence of abnormal bone marrow attenuation on VNCa images by using color-coded maps and performed a quantitative analysis of CT numbers on VNCa images. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values. Results: In the visual analysis, VNCa images had an overall sensitivity of 64.0%, specificity of 99.3%, accuracy of 93.9%, positive predictive value of 94.1%, and negative predictive value of 93.8%. The interobserver agreement was excellent (kappa = 0.85). CT numbers obtained from VNCa images were significantly different in vertebral bodies with and without edema (P <.001). Receiver operating characteristic analysis revealed an area under the curve of 0.922. A cutoff value of 247 provided sensitivity of 92.0%, specificity of 82.6%, accuracy of 84.0%, positive predictive value of 48.9%, and negative predictive value of 98.3% for the differentiation of edematous vertebral bodies. Conclusion: Visual and quantitative analyses of dual-energy VNCa images showed excellent diagnostic performance for assessing traumatic bone marrow edema in vertebral compression fractures. (C) RSNA, 2017
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [21] Axial Spondyloarthritis: Dual-Energy Virtual Noncalcium CT in the Detection of Bone Marrow Edema in the Sacroiliac Joints
    Wu, Haijun
    Zhang, Guangfeng
    Shi, Lei
    Li, Xiuhui
    Chen, Min
    Huang, Xiaoyu
    Cao, Ximing
    Tan, Shaoheng
    Cui, Yang
    Liang, Changhong
    RADIOLOGY, 2019, 290 (01) : 157 - 164
  • [22] The Role of a Virtual Noncalcium Dual-Energy CT Application in the Detection of Bone Marrow Edema in Peripheral Osteomyelitis
    Yan, Yet Yen
    Ouellette, Hugue A.
    Saththianathan, Mayuran
    Munk, Peter L.
    Mallinson, Paul I.
    Sheikh, Adnan
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2022, 73 (03): : 549 - 556
  • [23] Dual-Energy CT-based Display of Bone Marrow Edema in Osteoporotic Vertebral Compression Fractures: Impact on Diagnostic Accuracy of Radiologists with Varying Levels of Experience in Correlation to MR Imaging
    Kaup, Moritz
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Beeres, Martin
    Kromen, Wolfgang
    Albrecht, Moritz H.
    Lehnert, Thomas
    Boettcher, Marie
    Vogl, Thomas J.
    Bauer, Ralf W.
    RADIOLOGY, 2016, 280 (02) : 510 - 519
  • [24] Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single-source volume CT scanner
    Diekhoffa, T.
    Hermann, K. G.
    Pumberger, M.
    Hamm, B.
    Putzier, M.
    Fuchs, M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 59 - 65
  • [25] Fast kilovoltage (KV)-switching dual-energy computed tomography hydroxyapatite (HAP)-water decomposition technique for identifying bone marrow edema in vertebral compression fractures
    Pan, Junhan
    Yan, Luyou
    Gao, Hui
    He, Yewen
    Zhong, Zeya
    Li, Ping
    Zhang, Yaxi
    Guo, Ying
    Liao, Liangying
    Zhou, Shuwei
    Zhang, Kun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (03) : 604 - +
  • [26] Quantification of bone marrow edema using dual-energy CT at fracture sites in trauma
    Abbassi, Mashya
    Jain, Ashwin
    Shin, Donghoon
    Arasa, Carlota Andreu
    Li, Baojun
    Anderson, Stephan W.
    LeBedis, Christina A.
    EMERGENCY RADIOLOGY, 2022, 29 (04) : 691 - 696
  • [27] Quantification of bone marrow edema using dual-energy CT at fracture sites in trauma
    Mashya Abbassi
    Ashwin Jain
    Donghoon Shin
    Carlota Andreu Arasa
    Baojun Li
    Stephan W. Anderson
    Christina A. LeBedis
    Emergency Radiology, 2022, 29 : 691 - 696
  • [28] Dual-Energy Computed Tomographic Virtual Noncalcium Algorithm for Detection of Bone Marrow Edema in Acute Fractures: Early Experiences
    Reagan, Adrian C.
    Mallinson, Paul I.
    O'Connell, Timothy
    McLaughlin, Patrick D.
    Krauss, Bernhard
    Munk, Peter L.
    Nicolaou, Savvas
    Ouellette, Hugue A.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (05) : 802 - 805
  • [29] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Giovanni Foti
    William Mantovani
    Niccolò Faccioli
    Giacomo Crivellari
    Luigi Romano
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2021, 126 : 405 - 413
  • [30] Identification of bone marrow edema of the ankle: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Catania, Matteo
    Caia, Simone
    Romano, Luigi
    Beltramello, Alberto
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (10): : 1028 - 1036