Vertebral Compression Fractures: Third-Generation Dual-Energy CT for Detection of Bone Marrow Edema at Visual and Quantitative Analyses

被引:121
|
作者
Petritsch, Bernhard [1 ]
Kosmala, Aleksander [1 ]
Weng, Andreas M. [1 ]
Krauss, Bernhard [3 ]
Heidemeier, Anke [1 ]
Wagner, Richard [2 ]
Heintel, Timo M. [2 ]
Gassenmaier, Tobias [1 ]
Bley, Thorsten A. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Hosp Wurzburg, Dept Trauma Hand Plast & Reconstruct Surg, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[3] Siemens Healthcare, Imaging & Therapy Div, Forchheim, Germany
关键词
INITIAL-EXPERIENCE; PERCUTANEOUS VERTEBROPLASTY; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; BASIC PRINCIPLES; LESIONS; DIAGNOSIS; IMAGES; DECOMPOSITION; OSTEOPOROSIS;
D O I
10.1148/radiol.2017162165
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the diagnostic performance of a third-generation dual-energy computed tomographic (CT) virtual noncalcium (VNCa) technique for detection of traumatic bone marrow edema in patients with vertebral compression fractures. Materials and Methods: This prospective study was approved by the institutional review board. Informed consent was obtained from all participants. Twenty-two consecutive patients with 37 morphologic vertebral fractures were studied between October 2015 and May 2016. All patients underwent dual- energy CT (90 kV and 150 kV with a tin filter) and 3-T magnetic resonance (MR) imaging. Two independent readers visually evaluated all vertebral bodies (n = 163) for the presence of abnormal bone marrow attenuation on VNCa images by using color-coded maps and performed a quantitative analysis of CT numbers on VNCa images. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values. Results: In the visual analysis, VNCa images had an overall sensitivity of 64.0%, specificity of 99.3%, accuracy of 93.9%, positive predictive value of 94.1%, and negative predictive value of 93.8%. The interobserver agreement was excellent (kappa = 0.85). CT numbers obtained from VNCa images were significantly different in vertebral bodies with and without edema (P <.001). Receiver operating characteristic analysis revealed an area under the curve of 0.922. A cutoff value of 247 provided sensitivity of 92.0%, specificity of 82.6%, accuracy of 84.0%, positive predictive value of 48.9%, and negative predictive value of 98.3% for the differentiation of edematous vertebral bodies. Conclusion: Visual and quantitative analyses of dual-energy VNCa images showed excellent diagnostic performance for assessing traumatic bone marrow edema in vertebral compression fractures. (C) RSNA, 2017
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [1] Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT
    Wang, Chien-Kuo
    Tsai, Jen-Ming
    Chuang, Ming-Tsung
    Wang, Min-Tsung
    Huang, Kuo-Yuan
    Lin, Ruey-Mo
    RADIOLOGY, 2013, 269 (02) : 524 - 532
  • [2] Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI
    Guillaume Bierry
    Aïna Venkatasamy
    Stéphane Kremer
    Jean-Claude Dosch
    Jean-Louis Dietemann
    Skeletal Radiology, 2014, 43 : 485 - 492
  • [3] Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI
    Bierry, Guillaume
    Venkatasamy, Aina
    Kremer, Stephane
    Dosch, Jean-Claude
    Dietemann, Jean-Louis
    SKELETAL RADIOLOGY, 2014, 43 (04) : 485 - 492
  • [4] Dual-Energy CT of Material Decomposition Analysis for Detection with Bone Marrow Edema in Patients with Vertebral Compression Fractures
    Akisato, Kyouhei
    Nishihara, Reisuke
    Okazaki, Hajime
    Masuda, Takanori
    Hironobe, Ayako
    Ishizaki, Hiromi
    Shota, Kondo
    Yamaguchi, Hiroshi
    Funama, Yoshinori
    ACADEMIC RADIOLOGY, 2020, 27 (02) : 227 - 232
  • [5] Bone marrow edema in sacroiliitis: detection with dual-energy CT
    Min Chen
    Nele Herregods
    Jacob L. Jaremko
    Philippe Carron
    Dirk Elewaut
    Filip Van den Bosch
    Lennart Jans
    European Radiology, 2020, 30 : 3393 - 3400
  • [6] Bone marrow edema in sacroiliitis: detection with dual-energy CT
    Chen, Min
    Herregods, Nele
    Jaremko, Jacob L.
    Carron, Philippe
    Elewaut, Dirk
    Van den Bosch, Filip
    Jans, Lennart
    EUROPEAN RADIOLOGY, 2020, 30 (06) : 3393 - 3400
  • [7] Nondisplaced fractures on hip CT: added value of dual-energy CT virtual non-calcium imaging for detection of bone marrow edema using visual and quantitative analyses
    Jang, Seong Won
    Chung, Bo Mi
    Kim, Wan Tae
    Gil, Jea Ryung
    ACTA RADIOLOGICA, 2019, 60 (11) : 1465 - 1473
  • [8] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Giovanni Foti
    Alberto Beltramello
    Matteo Catania
    Stefano Rigotti
    Gerardo Serra
    Giovanni Carbognin
    La radiologia medica, 2019, 124 : 487 - 494
  • [9] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Foti, Giovanni
    Beltramello, Alberto
    Catania, Matteo
    Rigotti, Stefano
    Serra, Gerardo
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (06): : 487 - 494
  • [10] Diagnostic accuracy of dual-energy computed tomography in bone marrow edema with vertebral compression fractures: A meta-analysis
    Yang, Pei
    Wu, Guangyao
    Chang, Xiaodan
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 124 - 129