Refractive outcomes of intraocular lens power calculation using different corneal power measurements with a new optical biometer

被引:25
|
作者
Savini, Giacomo [1 ]
Negishi, Kazuno [2 ]
Hoffer, Kenneth J. [3 ,4 ]
Lomoriello, Domenico Schiano [1 ]
机构
[1] GB Bietti Fdn IRCCS, Via Livenza 3, Rome, Italy
[2] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
[3] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[4] St Marys Eye Ctr, Santa Monica, CA USA
来源
关键词
DUAL SCHEIMPFLUG ANALYZER; COHERENCE TOMOGRAPHY; ACCURACY; SYSTEM; PREDICTION; SURGERY; DEVICE; SRK/T;
D O I
10.1016/j.jcrs.2018.03.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the results of intraocular lens (IOL) power calculation using different comeal power measurements provided by an optical biometer combined with a dual Scheimpflug analyzer and a Placido disk topographer (Galilei G6). Setting: G.B. Bietti Foundation, Rome, Italy, and Keio University Hospital, Tokyo, Japan. Design: Evaluation of diagnostic technology. Methods: Consecutive patients having cataract surgery were enrolled. The IOL power was calculated with the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Different options were used to calculate the corneal power: simulated keratometry (K) based on anterior comeal surface measurements only and total comeal power (TCP) based on ray tracing through both corneal surfaces. Three TCP measurements (TCP1, TCP2, and TCP-1014 were evaluated. Results: The study analyzed 118 eyes. The mean values of simulated K (43.74 diopters [D] +/- 1.40 [SD)), TCP1 (43.13 +/- 1.35 D), TCP2 (41.87 +/- 1.30 D), and TCP-IOL (42.62 +/- 1.35 D) were significantly different (P <.0001). The best results were obtained using simulated K: the median absolute error ranged between 0.22 D and 0.29 D and the percentage of eyes with a prediction error of +/- 0.50 D or less, between 76.2% and 84.7%, depending on the formula. After constant optimization, the results using any TCP value and simulated K were similar with no statistically significant differences. Conclusions: Biometric measurements provided by the Scheimpflug Placido optical biometer can be used to accurately calculate the IOL power. Simulated K and TCP led to similar outcomes after constant optimization. (C) 2018 ASCRS and ESCRS.
引用
收藏
页码:701 / 708
页数:8
相关论文
共 50 条
  • [41] A new centralperipheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgery
    Saiki, Megumi
    Negishi, Kazuno
    Kato, Naoko
    Arai, Hiroyuki
    Toda, Ikuko
    Torii, Hidemasa
    Dogru, Murat
    Tsubota, Kazuo
    ACTA OPHTHALMOLOGICA, 2013, 91 (02) : e133 - e139
  • [42] Calculating intraocular lens power after refractive corneal surgery
    Hoffer, KJ
    Monica, S
    ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (04) : 500 - 501
  • [43] Determining intraocular lens power following corneal refractive surgery
    Savinit, Giacomo
    Zanini, Maurizio
    Barboni, Piero
    EXPERT REVIEW OF OPHTHALMOLOGY, 2006, 1 (02) : 229 - 240
  • [44] Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis
    Helaly, Hany A.
    El-Hifnawy, Mohammad A. M.
    Shaheen, Mohamed Shafik
    Abou El-Kheir, Amr F.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (01) : 122 - 128
  • [45] Intraocular lens constant optimization in toric intraocular lens calculation using keratometry and total corneal power
    Liang, Jianheng
    Liu, Hui
    Zhou, Suowang
    Zhou, Lijing
    Qian, Zhuyun
    Jiang, Lihong
    Chen, Xu
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 230 - 238
  • [46] Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive Surgery
    Wang, Li
    Tang, Maolong
    Huang, David
    Weikert, Mitchell P.
    Koch, Douglas D.
    OPHTHALMOLOGY, 2015, 122 (12) : 2443 - 2449
  • [47] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [48] Intraocular lens power calculation after corneal refractive surgery: Double-K method
    Aramberri, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11): : 2063 - 2068
  • [49] Use of the Pentacam True Net Corneal Power for Intraocular Lens Calculation in Eyes After Refractive Corneal Surgery
    Kim, Sang Woo
    Kim, Eung Kweon
    Cho, Beom-Jin
    Kim, Sun Woong
    Song, Ki Yung
    Kim, Tae-im
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) : 285 - 289
  • [50] Intraocular lens power calculation following laser refractive surgery
    Hodge, Christopher
    McAlinden, Colm
    Lawless, Michael
    Chan, Colin
    Sutton, Gerard
    Martin, Aifric
    EYE AND VISION, 2015, 2