Refractive outcomes of intraocular lens power calculation using different corneal power measurements with a new optical biometer

被引:25
|
作者
Savini, Giacomo [1 ]
Negishi, Kazuno [2 ]
Hoffer, Kenneth J. [3 ,4 ]
Lomoriello, Domenico Schiano [1 ]
机构
[1] GB Bietti Fdn IRCCS, Via Livenza 3, Rome, Italy
[2] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
[3] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[4] St Marys Eye Ctr, Santa Monica, CA USA
来源
关键词
DUAL SCHEIMPFLUG ANALYZER; COHERENCE TOMOGRAPHY; ACCURACY; SYSTEM; PREDICTION; SURGERY; DEVICE; SRK/T;
D O I
10.1016/j.jcrs.2018.03.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the results of intraocular lens (IOL) power calculation using different comeal power measurements provided by an optical biometer combined with a dual Scheimpflug analyzer and a Placido disk topographer (Galilei G6). Setting: G.B. Bietti Foundation, Rome, Italy, and Keio University Hospital, Tokyo, Japan. Design: Evaluation of diagnostic technology. Methods: Consecutive patients having cataract surgery were enrolled. The IOL power was calculated with the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Different options were used to calculate the corneal power: simulated keratometry (K) based on anterior comeal surface measurements only and total comeal power (TCP) based on ray tracing through both corneal surfaces. Three TCP measurements (TCP1, TCP2, and TCP-1014 were evaluated. Results: The study analyzed 118 eyes. The mean values of simulated K (43.74 diopters [D] +/- 1.40 [SD)), TCP1 (43.13 +/- 1.35 D), TCP2 (41.87 +/- 1.30 D), and TCP-IOL (42.62 +/- 1.35 D) were significantly different (P <.0001). The best results were obtained using simulated K: the median absolute error ranged between 0.22 D and 0.29 D and the percentage of eyes with a prediction error of +/- 0.50 D or less, between 76.2% and 84.7%, depending on the formula. After constant optimization, the results using any TCP value and simulated K were similar with no statistically significant differences. Conclusions: Biometric measurements provided by the Scheimpflug Placido optical biometer can be used to accurately calculate the IOL power. Simulated K and TCP led to similar outcomes after constant optimization. (C) 2018 ASCRS and ESCRS.
引用
收藏
页码:701 / 708
页数:8
相关论文
共 50 条
  • [31] Intraocular lens power calculation after myopic laser in situ keratomileusis: Estimating the corneal refractive power
    Awwad, Shady T.
    Manasseh, Christian
    Bowman, R. Wayne
    Cavanagh, H. Dwight
    Verity, Steven
    Mootha, Vinod
    McCulley, James P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (07): : 1070 - 1076
  • [32] Intraocular lens power calculation after laser refractive surgery Corrective algorithm for corneal power estimation
    Jin, Haiying
    Holzer, Mike P.
    Rabsilber, Tanja
    Borkenstein, Andreas F.
    Lirnberger, Ii-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01): : 87 - 96
  • [33] Refractive Outcomes With New Generation Formulas for Intraocular Lens Power Calculation in Radial Keratotomy Patients
    Ferrara, Silvia
    Crincoli, Emanuele
    Savastano, Alfonso
    Savastano, Maria Cristina
    Catania, Fiammetta
    Rizzo, Stanislao
    CORNEA, 2024, 43 (02) : 178 - 183
  • [34] Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer
    Savini, Giacomo
    Hoffer, Kenneth J.
    Balducci, Nicole
    Barboni, Piero
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 27 - 33
  • [35] Intraocular lens power calculation after corneal refractive surgery remains challenging - Reply
    Seitz, B
    Langenbucher, A
    OPHTHALMOLOGY, 2000, 107 (02) : 227 - 228
  • [36] Intraocular Lens Power Calculation Without Corneal Parameters: A New Option
    Rosa, Nicola
    Zeppa, Lucio
    De Bernardo, Maddalena
    Coppola, Alessia
    Zeppa, Lucia
    Borrelli, Maria
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2021, 47 (04): : 208 - 212
  • [37] Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation
    Zhang, Zina
    Thomas, Logan William
    Leu, Szu-Yen
    Carter, Steven
    Garg, Sumit
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (09) : 813 - 817
  • [38] Intraocular lens power calculation after refractive surgery
    Argento, C
    Cosentino, MJ
    Badoza, D
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1346 - 1351
  • [39] The role of the epithelium in intraocular lens and corneal power calculation
    Wendelstein, Jascha A.
    Atchison, David A.
    Gatinel, Damien
    Cooke, David L.
    Langenbucher, Achim
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2025, 45 (02) : 372 - 382
  • [40] Principles of corneal measurement for intraocular lens power calculation
    Findl, Oliver
    Hirnschall, Nino
    EXPERT REVIEW OF OPHTHALMOLOGY, 2016, 11 (02) : 93 - 99