Refractive outcomes of intraocular lens power calculation using different corneal power measurements with a new optical biometer

被引:25
|
作者
Savini, Giacomo [1 ]
Negishi, Kazuno [2 ]
Hoffer, Kenneth J. [3 ,4 ]
Lomoriello, Domenico Schiano [1 ]
机构
[1] GB Bietti Fdn IRCCS, Via Livenza 3, Rome, Italy
[2] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
[3] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[4] St Marys Eye Ctr, Santa Monica, CA USA
来源
关键词
DUAL SCHEIMPFLUG ANALYZER; COHERENCE TOMOGRAPHY; ACCURACY; SYSTEM; PREDICTION; SURGERY; DEVICE; SRK/T;
D O I
10.1016/j.jcrs.2018.03.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the results of intraocular lens (IOL) power calculation using different comeal power measurements provided by an optical biometer combined with a dual Scheimpflug analyzer and a Placido disk topographer (Galilei G6). Setting: G.B. Bietti Foundation, Rome, Italy, and Keio University Hospital, Tokyo, Japan. Design: Evaluation of diagnostic technology. Methods: Consecutive patients having cataract surgery were enrolled. The IOL power was calculated with the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Different options were used to calculate the corneal power: simulated keratometry (K) based on anterior comeal surface measurements only and total comeal power (TCP) based on ray tracing through both corneal surfaces. Three TCP measurements (TCP1, TCP2, and TCP-1014 were evaluated. Results: The study analyzed 118 eyes. The mean values of simulated K (43.74 diopters [D] +/- 1.40 [SD)), TCP1 (43.13 +/- 1.35 D), TCP2 (41.87 +/- 1.30 D), and TCP-IOL (42.62 +/- 1.35 D) were significantly different (P <.0001). The best results were obtained using simulated K: the median absolute error ranged between 0.22 D and 0.29 D and the percentage of eyes with a prediction error of +/- 0.50 D or less, between 76.2% and 84.7%, depending on the formula. After constant optimization, the results using any TCP value and simulated K were similar with no statistically significant differences. Conclusions: Biometric measurements provided by the Scheimpflug Placido optical biometer can be used to accurately calculate the IOL power. Simulated K and TCP led to similar outcomes after constant optimization. (C) 2018 ASCRS and ESCRS.
引用
收藏
页码:701 / 708
页数:8
相关论文
共 50 条
  • [1] Comparison of different formulas for intraocular lens power calculation using a new optical biometer
    Kaya, F.
    Kocak, I.
    Aydin, A.
    Baybora, H.
    Karabela, Y.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (08): : 717 - 722
  • [2] A new formula for intraocular lens power calculation after refractive corneal surgery
    Camellin, M
    Calossi, A
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 187 - 199
  • [3] Calculation of intraocular lens power after corneal refractive surgery
    Chan, Colin C. K.
    Hodge, Chris
    Lawless, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (07): : 640 - 644
  • [4] Intraocular Lens Power Calculation After Corneal Refractive Surgery
    Feiz, Vahid
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2010, 17 (01) : 63 - 68
  • [5] Intraocular lens power calculation after corneal refractive surgery
    Kalyani, Sachin D.
    Kim, Alisa
    Ladas, John G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (04) : 357 - 362
  • [6] Intraocular lens power calculation after corneal refractive surgery
    Stopyra, Wiktor
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [7] Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1193 - 1197
  • [8] Intraocular lens power calculation using adjusted corneal power in eyes after myopic corneal refractive surgery
    Tan, Qian
    Lin, Ding
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [9] Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer
    Kim, Se Young
    Lee, Seung Hyun
    Kim, Na Rae
    Chin, Hee Seung
    Jung, Ji Won
    PLOS ONE, 2020, 15 (01):
  • [10] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    EYE AND VISION, 2018, 5