Development and evaluation of an automatic contour propagation method for 4D radiotherapy

被引:0
|
作者
Lin, L.
Shi, C.
Liu, Y.
Swanson, G.
Papanikolaou, N.
机构
[1] Univ Texas, Hlth Sci Ctr, San Antonio, TX USA
[2] Canc Therapy & Res Ctr S Texas, San Antonio, TX 78229 USA
关键词
D O I
10.1118/1.2761708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and evaluate automatic contour propagation method for 4D radiotherapy Method and Materials: 4D CT images of one lung cancer patient and dynamic phantom images were acquired and resorted into ten respiratory phases. Demons deformable registration was performed to find the deformation field from the end‐exhale fixed phase to moving phases such as the end‐inhale phase. Regions of interest (ROIs) were contoured in the fixed phase with the Pinnacle3 treatment planning system. The planar parallel contours were reconstructed as the 3D binary mask image data which has zero value outside and non‐zero value inside of the 3D outline of contouring. The 3D contour image data were transformed to another moving phase using the deformation field from the image registration result. On each 2D plane the binary image boundary was found to trace the closed intersection points. To assess the quality of the automatic contour propagation method, the contour for the moving phase was delineated manually. Visual inspection between the contour propagation and manual contour was performed as the qualitative evaluation. Two indices were used as the quantitative examination. One was the match index to indicate how well two contour sets match each other. The other was volume difference evaluation between two contour sets. Results: The demons deformable registration results show good alignment for both the phantom and the patient. The match index between manual and automatic contouring ranged from 0.96 to 0.99 for the dynamic phantom and from 0.95 to 0.99 for the lung patient. The volume differences were between 0.75 and 2.97 percent for the dynamic phantom and between 1.50 and 7.32 percent for the lung patient. Conclusions: The proposed automatic contour propagation method is simple and feasible without surface construction. It is a variable method for defining the ROIs for large amount of 4DCT data sets. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2637 / 2638
页数:2
相关论文
共 50 条
  • [31] 4D in-vivo dosimetry in radiotherapy
    Cherpak, A. J.
    Buckley, L.
    Ding, W.
    Ashton, R.
    Cygler, J. E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S52 - S52
  • [32] Automatic contour propagation of breast and heart for re-planning in breast cancer radiotherapy
    Sikkes, G. G.
    Meijers, L. T. C.
    Kotte, A. N. T. J.
    Van Dam, I. E.
    Van Asselen, B.
    Van den Bongard, H. J. G. D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S138 - S138
  • [33] Data compression in adaptive and 4D radiotherapy
    Chen, Q.
    Chen, M.
    Lu, W.
    Ruchala, K.
    Olivera, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S192 - S192
  • [34] 4D in-vivo dosimetry in radiotherapy
    Cygler, J.
    Saoudi, A.
    Cherpak, A.
    Ding, W.
    Ashton, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2402 - 2402
  • [35] Dosimetric Validation of Respiratory Motion Margins for Patients With Pancreatic Cancer Using Deformable 4D Contour Propagation
    Yang, X.
    Reese, A. S.
    Mutaf, Y. D.
    Prado, K. L.
    Sharma, N. K.
    Feigenberg, S. J.
    Regine, W. F.
    Yi, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S778 - S779
  • [36] Compensation of Target Distortion of Pancreatic Tumor in Free-Breathing CT Using 4D Contour Propagation
    Yang, X.
    Reese, A.
    Mutaf, Y.
    Yi, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3700 - 3700
  • [37] Development of composite springs using 4D printing method
    Suong Van Hoa
    COMPOSITE STRUCTURES, 2019, 210 : 869 - 876
  • [38] Automatic contouring in 4D radiation therapy
    Chao, M.
    Schreibmann, E.
    Li, T.
    Koong, A.
    Goodman, K. A.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S649 - S649
  • [39] 4D tracking radiotherapy delivery evaluation for five patients with mobile lung tumor
    Liu, Y.
    Lin, B.
    Papanikolaou, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S614 - S614
  • [40] Motion encoded beamlets for optimization and evaluation in four-dimensional (4D) radiotherapy
    Lu, W.
    Olivera, G.
    Chen, Q.
    Chen, M.
    Pan, Y.
    Schnarr, E.
    Ruchala, K.
    MEDICAL PHYSICS, 2006, 33 (06) : 2042 - 2043