Development and evaluation of an automatic contour propagation method for 4D radiotherapy

被引:0
|
作者
Lin, L.
Shi, C.
Liu, Y.
Swanson, G.
Papanikolaou, N.
机构
[1] Univ Texas, Hlth Sci Ctr, San Antonio, TX USA
[2] Canc Therapy & Res Ctr S Texas, San Antonio, TX 78229 USA
关键词
D O I
10.1118/1.2761708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and evaluate automatic contour propagation method for 4D radiotherapy Method and Materials: 4D CT images of one lung cancer patient and dynamic phantom images were acquired and resorted into ten respiratory phases. Demons deformable registration was performed to find the deformation field from the end‐exhale fixed phase to moving phases such as the end‐inhale phase. Regions of interest (ROIs) were contoured in the fixed phase with the Pinnacle3 treatment planning system. The planar parallel contours were reconstructed as the 3D binary mask image data which has zero value outside and non‐zero value inside of the 3D outline of contouring. The 3D contour image data were transformed to another moving phase using the deformation field from the image registration result. On each 2D plane the binary image boundary was found to trace the closed intersection points. To assess the quality of the automatic contour propagation method, the contour for the moving phase was delineated manually. Visual inspection between the contour propagation and manual contour was performed as the qualitative evaluation. Two indices were used as the quantitative examination. One was the match index to indicate how well two contour sets match each other. The other was volume difference evaluation between two contour sets. Results: The demons deformable registration results show good alignment for both the phantom and the patient. The match index between manual and automatic contouring ranged from 0.96 to 0.99 for the dynamic phantom and from 0.95 to 0.99 for the lung patient. The volume differences were between 0.75 and 2.97 percent for the dynamic phantom and between 1.50 and 7.32 percent for the lung patient. Conclusions: The proposed automatic contour propagation method is simple and feasible without surface construction. It is a variable method for defining the ROIs for large amount of 4DCT data sets. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2637 / 2638
页数:2
相关论文
共 50 条
  • [21] 4D Ultrasound Calibration for Radiotherapy Guidance Using Automatic Intramodality Image Registration
    Schlosser, J.
    Kirmizibayrak, C.
    Shamdasani, V.
    Metz, S.
    Hristov, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3617 - 3617
  • [22] A morphing active surface model for automatic re-contouring in 4D radiotherapy
    Han, Xiao
    Hibbard, Lyndon S.
    Brame, Scott
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [23] Establishing a framework to implement 4D XCAT Phantom for 4D radiotherapy research
    Panta, Raj K.
    Segars, Paul
    Yin, Fang-Fang
    Cai, Jing
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (04) : 565 - 570
  • [24] Evaluation of an Automated 4D-CT Contour Propagation Tool used to Define an Internal Target Volume for Lung Cancer Radiotherapy
    Gaede, S.
    Olsthoorn, J.
    Louie, A. V.
    Palma, D.
    Yu, E.
    Ahmad, B.
    Yaremko, B.
    Chen, J.
    Bzdusek, K.
    Rodrigues, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S455 - S455
  • [25] An evaluation of an automated 4D-CT contour propagation tool to define an internal gross tumour volume for lung cancer radiotherapy
    Gaede, Stewart
    Olsthoorn, Jason
    Louie, Alexander V.
    Palma, David
    Yu, Edward
    Yaremko, Brian
    Ahmad, Belal
    Chen, Jeff
    Bzdusek, Karl
    Rodrigues, George
    RADIOTHERAPY AND ONCOLOGY, 2011, 101 (02) : 322 - 328
  • [26] A deformable phantom for 4D radiotherapy verification: Design and image registration evaluation
    Serban, Monica
    Heath, Emily
    Stroian, Gabriela
    Collins, D. Louis
    Seuntjens, Jan
    MEDICAL PHYSICS, 2008, 35 (03) : 1094 - 1102
  • [27] A simplified method for delineation of target volumes in 4D oesophageal cancer radiotherapy
    Lewis, G.
    Nicholas, O.
    Gwynne, S.
    Crosby, T.
    Chand, A.
    Thomas, B.
    Wills, L.
    Radhakrishna, G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1100 - S1101
  • [28] Development of a Dynamic Phantom for Validation of 4D Imaging and Radiotherapy Treatment Delivery
    Lowe, M.
    Webster, G.
    Rowbottom, C.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S44 - S44
  • [29] Evaluation of automatic 4D face recognition using surface and texture registration
    Papatheodorou, T
    Rueckert, D
    SIXTH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION, PROCEEDINGS, 2004, : 321 - 326
  • [30] 4D radiotherapy: imaging and treatment planning
    Rietzel, E.
    Chen, G. T. Y.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 137 - 138