Non-invasive microfluidic gap junction assay

被引:23
|
作者
Chen, Sisi [1 ]
Lee, Luke P. [1 ]
机构
[1] Univ Calif Berkeley, Dept Bioengn, Berkeley Sensor & Actuator Ctr, Biomol Nanotechnol Ctr, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
DYE TRANSFER; COMMUNICATION; ELECTROPORATION; INHIBITION; PERMEABILITY; LIMITATIONS; CELLS; CA2+;
D O I
10.1039/b919392h
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Gap junctions are protein channels between cells that allow direct electrical and metabolic coupling via the exchange of biomolecules and ions. Their expression, though ubiquitous in most mammalian cell types, is especially important for the proper functioning of cardiac and neuronal systems. Many existing methods for studying gap junction communication suffer from either unquantifiable data or difficulty of use. Here, we measure the extent of dye spread and effective diffusivities through gap junction connected cells using a quantitative microfluidic cell biology platform. After loading dye by hydrodynamic focusing of calcein/AM, dye transfer dynamics into neighboring, unexposed cells can be monitored via timelapse fluorescent microscopy. By using a selective microfluidic dye loading over a confluent layer of cells, we found that high expression of gap junctions in C6 cells transmits calcein across the monolayer with an effective diffusivity of 3.4 x 10(-13) m(2)/s, which are highly coupled by Cx43. We also found that the gap junction blocker 18 alpha-GA works poorly in the presence of serum even at high concentrations (50 mu M); however, it is highly effective down to 2.5 mu M in the absence of serum. Furthermore, when the drug is washed out, dye spread resumes rapidly within 1 min for all doses, indicating the drug does not affect transcriptional regulation of connexins in these Cx43+ cells, in contrast to previous studies. This integrated microfluidic platform enables the in situ monitoring of gap junction communication, yielding dynamic information about intercellular molecular transfer and pharmacological inhibition and recovery.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 50 条
  • [41] Mammalian cell growth characterisation by a non-invasive plate reader assay
    Grob, Alice
    Bena, Chiara Enrico
    Di Blasi, Roberto
    Pessina, Daniele
    Sood, Matthew
    Yunyue, Zhou
    Bosia, Carla
    Isalan, Mark
    Ceroni, Francesca
    NATURE COMMUNICATIONS, 2024, 15 (01)
  • [42] Non-invasive muscle contraction assay to study rodent models of sarcopenia
    Chi-Sung Chiu
    Hans Weber
    Sharon Adamski
    Albert Rauch
    Michael A Gentile
    Stephen E Alves
    Gary Kath
    Osvaldo Flores
    Hilary A Wilkinson
    BMC Musculoskeletal Disorders, 12
  • [43] Optimized Potentiometric Assay for Non-invasive Investigation of Skin Antioxidant Activity
    Brainina, Khiena Z.
    Markina, Maria G.
    Stozhko, Natalia Yu.
    ELECTROANALYSIS, 2018, 30 (10) : 2405 - 2412
  • [44] UroSEEK: A Novel Non-Invasive Molecular Assay for Surveillance of Bladder Cancer
    Springer, Simeon
    Pena, Maria Del Carmen Rodriguez
    Wang, Yuxuan
    Taheri, Diana
    Tregnago, Aline C.
    Bezerra, Stephania M.
    VandenBussche, Christopher
    Fujita, Kazutoshi
    Baydar, Dilek
    da Cunha, Isabela W.
    Yu, Lijia
    Bivalacqua, Trinity J.
    Dickman, Kathleen G.
    Grollman, Arthur P.
    Hruban, Ralph
    Tomasetti, Cristian
    Papadopoulos, Nickolas
    Kinzler, Kenneth W.
    Vogelstein, Bert
    Netto, George J.
    MODERN PATHOLOGY, 2018, 31 : 389 - 389
  • [45] A non-invasive isotope assay to measure human spermatogenesis kinetics in vivo
    Turek, P
    Misell, LM
    Shefi, S
    Santi, N
    Holochwost, D
    Hellerstein, M
    JOURNAL OF ANDROLOGY, 2005, : 74 - 74
  • [46] UROSEEK: A NOVEL NON-INVASIVE MOLECULAR ASSAY FOR SURVEILLANCE OF BLADDER CANCER
    Springer, Simeon
    Pena, Maria Del Carmen Rodriguez
    Tregnago, Aline
    Taheri, Diana
    Bezerra, Stephania
    Cunha, Isabela
    Fujita, Kazutoshi
    Baydar, Dilek
    Bivalacqua, Trinity
    Papadopoulos, Nickolas
    Kinzler, Kenneth W.
    Vogelstein, Bert
    Netto, George
    JOURNAL OF UROLOGY, 2018, 199 (04): : E864 - E864
  • [47] A microfluidic sucrose gap device for electrical measurement of gap junction connectivity
    Dungan, J.
    Mathews, J.
    Levin, M.
    Koomson, V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2025, 96 (02):
  • [48] BP neural network for non-invasive IGBT junction temperature online detection
    Liu, Li
    Peng, Qianlei
    Jiang, Huaping
    Ran, Li
    Wang, Yang
    Du, Changhong
    Chen, Jian
    Zhou, Hongbo
    Chen, Yang
    Peng, Zhiyuan
    MICROELECTRONICS RELIABILITY, 2023, 141
  • [49] PROS AND CONS - NON-INVASIVE OR INVASIVE DIAGNOSTICS IN CARDIOLOGY - ARGUMENTS FOR A NON-INVASIVE PROCEDURE
    BLOMER, H
    INTERNIST, 1981, 22 (11): : 664 - 671
  • [50] CONTROVERSIAL STANDPOINTS IN CARDIOLOGY - NON-INVASIVE OR INVASIVE DIAGNOSTICS - CORONARY INSUFFICIENCY - NON-INVASIVE
    BLOMER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1981, 70 (04): : 328 - 328