Gap junctions are protein channels between cells that allow direct electrical and metabolic coupling via the exchange of biomolecules and ions. Their expression, though ubiquitous in most mammalian cell types, is especially important for the proper functioning of cardiac and neuronal systems. Many existing methods for studying gap junction communication suffer from either unquantifiable data or difficulty of use. Here, we measure the extent of dye spread and effective diffusivities through gap junction connected cells using a quantitative microfluidic cell biology platform. After loading dye by hydrodynamic focusing of calcein/AM, dye transfer dynamics into neighboring, unexposed cells can be monitored via timelapse fluorescent microscopy. By using a selective microfluidic dye loading over a confluent layer of cells, we found that high expression of gap junctions in C6 cells transmits calcein across the monolayer with an effective diffusivity of 3.4 x 10(-13) m(2)/s, which are highly coupled by Cx43. We also found that the gap junction blocker 18 alpha-GA works poorly in the presence of serum even at high concentrations (50 mu M); however, it is highly effective down to 2.5 mu M in the absence of serum. Furthermore, when the drug is washed out, dye spread resumes rapidly within 1 min for all doses, indicating the drug does not affect transcriptional regulation of connexins in these Cx43+ cells, in contrast to previous studies. This integrated microfluidic platform enables the in situ monitoring of gap junction communication, yielding dynamic information about intercellular molecular transfer and pharmacological inhibition and recovery.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 50 条
  • [21] A non-invasive water-borne hormone assay for amphibians
    Gabor, Caitlin R.
    Bosch, Jaime
    Fries, Joe N.
    Davis, Drew R.
    AMPHIBIA-REPTILIA, 2013, 34 (02) : 151 - 162
  • [22] A telomere depletion assay for non-invasive prenatal diagnosis by FISH
    Hulten, M
    Tankimanonova, M
    Dhanjal, S
    JOURNAL OF MEDICAL GENETICS, 2002, 39 : S24 - S24
  • [23] NON-INVASIVE
    SPODICK, DH
    ANNALS OF INTERNAL MEDICINE, 1983, 99 (04) : 569 - 569
  • [24] Recent Advances of Microfluidic Platform for Cell Based Non-Invasive Prenatal Diagnosis
    Jou, Hei-Jen
    Lo, Pei-Hsuan
    Ling, Pei-Ying
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (02)
  • [25] Multiplexed centrifugal microfluidic system for rapid and non-invasive detection of myocardial fibrosis
    Wang, Luhai
    Sun, Jiaze
    Dai, Siwei
    Zhang, Pengfei
    Zhu, Yefei
    Zhang, Yu
    ANALYTICAL METHODS, 2025, 17 (03) : 601 - 610
  • [26] Module for real time non-invasive control of the electroosmotic flow in microfluidic systems
    Szekely, L
    Freitag, R
    ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) : 165 - 171
  • [27] Microfluidic contact lenses for unpowered, continuous and non-invasive intraocular pressure monitoring
    An, Hongbin
    Chen, Liangzhou
    Liu, Xiaojun
    Zhao, Bin
    Zhang, Hong
    Wu, Zhigang
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 295 : 177 - 187
  • [28] Non-invasive assessment of liver fibrosis: The gap between ideal and real
    Kim, Seung Up
    Han, Kwang-Hyub
    Ahn, Sang Hoon
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 (06) : 937 - 939
  • [29] INVASIVE OR NON-INVASIVE MONITORING
    HUGENHOL.PG
    HEIKKILA, J
    HAGEMEIJ.F
    ARNTZENI.AC
    POOL, J
    PALADINO, D
    CIRCULATION, 1972, 46 (04) : 75 - &
  • [30] DEADSPACE, INVASIVE AND NON-INVASIVE
    FLETCHER, R
    BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (03) : 245 - 249