Multi-echo balanced SSFP with a sequential phase-encoding order for functional MR imaging at 7T

被引:1
|
作者
Liang, Huilou [1 ,2 ]
Pan, Ziyi [3 ]
Qian, Chencan [1 ,2 ]
Liu, Chengwen [4 ]
Sun, Kaibao [1 ]
Weng, Dehe [5 ]
An, Jing [5 ]
Zhuo, Yan [1 ,2 ]
Wang, Danny J. J. [6 ]
Guo, Hua [3 ]
Xue, Rong [1 ,2 ,7 ]
机构
[1] Chinese Acad Sci, Beijing MRI Ctr Brain Res, Inst Biophys, State Key Lab Brain & Cognit Sci, 15 Datun Rd, Beijing 100101, Peoples R China
[2] Univ Chinese Acad Sci, Beijing, Peoples R China
[3] Tsinghua Univ, Ctr Biomed Imaging Res, Sch Med, Dept Biomed Engn, Beijing, Peoples R China
[4] Cent South Univ, Xiangya Hosp 2, Med Psychol Ctr, Changsha, Peoples R China
[5] Siemens Shenzhen Magnet Resonance Ltd, Shenzhen, Peoples R China
[6] Univ Southern Calif, Mark & Mary Stevens Neuroimaging & Informat Inst, Lab FMRI Technol LOFT, Los Angeles, CA 90007 USA
[7] Beijing Inst Brain Disorders, Beijing, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
BOLD fMRI; echo-train readout; multi-echo; passband balanced SSFP; submillimeter in-plane resolution; ultrahigh field; GRADIENT-ECHO; HUMAN BRAIN; FMRI; SIGNAL; BSSFP; NOISE; OXYGENATION; REDUCTION; FREQUENCY; TRUEFISP;
D O I
10.1002/mrm.29301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a 2D multi-echo passband balanced SSFP (bSSFP) sequence using an echo-train readout with a sequential phase-encoding order (sequential multi-echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T. Methods As images of sequential multi-echo bSSFP exhibit multiple ghosts due to periodic k-space modulations, a GRAPPA-based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi-echo bSSFP and conventional single-echo bSSFP. Submillimeter-resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi-echo bSSFP, conventional single-echo bSSFP and standard gradient-echo EPI (GE-EPI). Results A higher mean structural similarity index was found between images of single-echo bSSFP and multi-echo bSSFP with a shorter echo train length (ETL). Multi-echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA-accelerated single-echo bSSFP (R = 2). In submillimeter-resolution fMRI experiments, multi-echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA-accelerated single-echo bSSFP (R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t-value and the number of significantly activated voxels were comparable between GE-EPI and multi-echo bSSFP (ETL = 3) that provides virtually distortion-free functional images and inherits the activation patterns of conventional bSSFP. Conclusion Sequential multi-echo bSSFP (ETL = 3) is suitable for fast fMRI with submillimeter in-plane resolution, and offers an option to accelerate bSSFP imaging without tSNR penalty like parallel imaging.
引用
收藏
页码:1303 / 1313
页数:11
相关论文
共 35 条
  • [21] Multi-spin-echo J-resolved spectroscopic imaging without water suppression:: application to a rat glioma at 7T
    Hérigault, G
    Zoula, S
    Rémy, C
    Décorps, M
    Ziegler, A
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 17 (3-6) : 140 - 148
  • [22] Topographical mapping of metabolic abnormalities in multiple sclerosis using rapid echo-less 3D-MR spectroscopic imaging at 7T
    Niess, Eva
    Dal-Bianco, Assunta
    Strasser, Bernhard
    Niess, Fabian
    Hingerl, Lukas
    Bachrata, Beata
    Motyka, Stanislav
    Rommer, Paulus
    Trattnig, Siegfried
    Bogner, Wolfgang
    NEUROIMAGE, 2025, 308
  • [23] Clinical Value of 3D T2*-weighted Imaging with Multi-echo Acquisition: Comparison with Conventional 2D T2*-weighted Imaging and 3D Phase-sensitive MR Imaging
    Kunimatsu, Akira
    Suzuki, Yuichi
    Hagiwara, Kazuchika
    Sasaki, Hiroki
    Mori, Harushi
    Katsura, Masaki
    Ohtomo, Kuni
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (03) : 205 - 211
  • [24] Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
    Kang, Daehun
    In, Myung-Ho
    Jo, Hang Joon
    Halverson, Maria A.
    Meyer, Nolan K.
    Ahmed, Zaki
    Gray, Erin M.
    Madhavan, Radhika
    Foo, Thomas K.
    Fernandez, Brice
    Black, David F.
    Welker, Kirk M.
    Trzasko, Joshua D.
    Huston III, John
    Bernstein, Matt A.
    Shu, Yunhong
    SENSORS, 2023, 23 (09)
  • [25] A proof-of-principle study of multi-site real-time functional imaging at 3T and 7T: Implementation and validation
    Baecke, Sebastian
    Luetzkendorf, Ralf
    Mallow, Johannes
    Luchtmann, Michael
    Tempelmann, Claus
    Stadler, Joerg
    Bernarding, Johannes
    SCIENTIFIC REPORTS, 2015, 5 : 8413
  • [26] A proof-of-principle study of multi-site real-time functional imaging at 3T and 7T: Implementation and validation
    Sebastian Baecke
    Ralf Lützkendorf
    Johannes Mallow
    Michael Luchtmann
    Claus Tempelmann
    Jörg Stadler
    Johannes Bernarding
    Scientific Reports, 5
  • [27] Adiabatic multi-echo 31P spectroscopic imaging (AMESING) at 7 T for the measurement of transverse relaxation times and regaining of sensitivity in tissues with short T2* values
    van der Kemp, W. J. M.
    Boer, V. O.
    Luijten, P. R.
    Stehouwer, B. L.
    Veldhuis, W. B.
    Klomp, D. W. J.
    NMR IN BIOMEDICINE, 2013, 26 (10) : 1299 - 1307
  • [28] Gender transition affects neural correlates of empathy: A resting state functional connectivity study with ultra high-field 7T MR imaging
    Spies, M.
    Hahn, A.
    Kranz, G. S.
    Sladky, R.
    Kaufmann, U.
    Hummer, A.
    Ganger, S.
    Kraus, C.
    Winkler, D.
    Seiger, R.
    Comasco, E.
    Windischberger, C.
    Kasper, S.
    Lanzenberger, R.
    NEUROIMAGE, 2016, 138 : 257 - 265
  • [29] Quantitative T 1 and T 2* carotid atherosclerotic plaque imaging using a three-dimensional multi-echo phase-sensitive inversion recovery sequence: a feasibility study
    Fujiwara Y.
    Maruyama H.
    Toyomaru K.
    Nishizaka Y.
    Fukamatsu M.
    Radiological Physics and Technology, 2018, 11 (2) : 156 - 164
  • [30] A whole-brain multi-subject functional MR imaging comparison of EPI spin-echo, asymmetric spin-echo and gradient-echo sequences at 1.5 t
    Kiehl, KA
    Smith, AM
    Forster, BB
    MacKay, A
    Whittall, KP
    Liddle, PF
    RADIOLOGY, 1997, 205 : 1043 - 1043