Quantitative T 1 and T 2* carotid atherosclerotic plaque imaging using a three-dimensional multi-echo phase-sensitive inversion recovery sequence: a feasibility study

被引:5
|
作者
Fujiwara Y. [1 ]
Maruyama H. [2 ]
Toyomaru K. [3 ]
Nishizaka Y. [3 ]
Fukamatsu M. [4 ]
机构
[1] Department of Medical Imaging, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Chuo-ku, Kumamoto
[2] Radiological Center, National Hospital Organization Kumamoto Saisyunsou Hospital, Kumamoto
[3] Course of Radiological Science, School of Health Sciences, Kumamoto University, Kumamoto
[4] Radiological Center, National Hospital Organization Kumamoto Medical Center, Kumamoto
基金
日本学术振兴会;
关键词
Black-blood imaging; Intra-plaque hemorrhage; Magnetic resonance imaging; Plaque imaging; Quantification; Quantitative MRI;
D O I
10.1007/s12194-018-0449-2
中图分类号
学科分类号
摘要
Magnetic resonance imaging (MRI) is widely used to detect carotid atherosclerotic plaques. Although it is important to evaluate vulnerable carotid plaques containing lipids and intra-plaque hemorrhages (IPHs) using T1-weighted images, the image contrast changes depending on the imaging settings. Moreover, to distinguish between a thrombus and a hemorrhage, it is useful to evaluate the iron content of the plaque using both T1-weighted and T2*-weighted images. Therefore, a quantitative evaluation of carotid atherosclerotic plaques using T1 and T2* values may be necessary for the accurate evaluation of plaque components. The purpose of this study was to determine whether the multi-echo phase-sensitive inversion recovery (mPSIR) sequence can improve T1 contrast while simultaneously providing accurate T1 and T2* values of an IPH. T1 and T2* values measured using mPSIR were compared to values from conventional methods in phantom and in vivo studies. In the phantom study, the T1 and T2* values estimated using mPSIR were linearly correlated with those of conventional methods. In the in vivo study, mPSIR demonstrated higher T1 contrast between the IPH phantom and sternocleidomastoid muscle than the conventional method. Moreover, the T1 and T2* values of the blood vessel wall and sternocleidomastoid muscle estimated using mPSIR were correlated with values measured by conventional methods and with values reported previously. The mPSIR sequence improved T1 contrast while simultaneously providing accurate T1 and T2* values of the neck region. Although further study is required to evaluate the clinical utility, mPSIR may improve carotid atherosclerotic plaque detection and provide detailed information about plaque components. © 2018, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:156 / 164
页数:8
相关论文
共 50 条
  • [1] Improvement in the contrast-to-noise ratio and quantitative measurement of T1 and T2* values for carotid atherosclerotic plaque using multi-echo phase-sensitive inversion recovery
    Yasuhiro Fujiwara
    Motohira Mio
    Radiological Physics and Technology, 2021, 14 : 186 - 192
  • [2] Improvement in the contrast-to-noise ratio and quantitative measurement of T1 and T2* values for carotid atherosclerotic plaque using multi-echo phase-sensitive inversion recovery
    Fujiwara, Yasuhiro
    Mio, Motohira
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (02) : 186 - 192
  • [3] Quantitative T1 mapping of the substantia nigra using phase-sensitive inversion recovery sequence at 3.0-T: a healthy volunteer study
    Fujiwara, Yasuhiro
    Hirai, Tetsuyoshi
    Ueda, Tomohiro
    Kumazoe, Hiroyuki
    Ito, Shigeki
    ACTA RADIOLOGICA, 2021, 62 (02) : 243 - 250
  • [4] Three-dimensional quantitative T1 and T2 mapping of the carotid artery: Sequence design and in vivo feasibility
    Coolen, Bram F.
    Poot, Dirk H. J.
    Liem, Madieke I.
    Smits, Loek P.
    Gao, Shan
    Kotek, Gyula
    Klein, Stefan
    Nederveen, Aart J.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1008 - 1017
  • [5] Simultaneous acquisition of high-contrast and quantitative liver T1 images using 3D phase-sensitive inversion recovery: a feasibility study
    Fujiwara, Yasuhiro
    Maruyama, Hirotoshi
    Kosaka, Nobuyuki
    Ishimori, Yoshiyuki
    ACTA RADIOLOGICA, 2017, 58 (08) : 899 - 905
  • [6] Three-Dimensional Phase-Sensitive Inversion-Recovery Turbo FLASH Sequence for the Evaluation of Left Ventricular Myocardial Scar
    Kino, Aya
    Zuehlsdorff, Sven
    Sheehan, John J.
    Weale, Peter J.
    Carroll, Timothy J.
    Jerecic, Renate
    Carr, James C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) : W381 - W388
  • [7] Improved Carotid Intraplaque Hemorrhage Imaging Using a Slab-Selective Phase-Sensitive Inversion-Recovery (SPI) Sequence
    Wang, Jinnan
    Ferguson, Marina S.
    Balu, Niranjan
    Yuan, Chun
    Hatsukami, Thomas S.
    Boernert, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) : 1332 - 1340
  • [8] Quantitative evaluation of focal liver lesions with T1 mapping using a phase-sensitive inversion recovery sequence on gadoxetic acid-enhanced MRI
    Mio, Motohira
    Fujiwara, Yasuhiro
    Tani, Kazuki
    Toyofuku, Tatsuo
    Maeda, Toshihiro
    Inoue, Toshiro
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
  • [9] The potential role of T2*-weighted multi-echo data image combination as an imaging marker for intraplaque hemorrhage in carotid plaque imaging
    Truong, My
    Hakansson, Claes
    HaileMichael, Makda
    Svensson, Jonas
    Latt, Jimmy
    Bloch, Karin Markenroth
    Siemund, Roger
    Goncalves, Isabel
    Wasselius, Johan
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [10] The potential role of T2*-weighted multi-echo data image combination as an imaging marker for intraplaque hemorrhage in carotid plaque imaging
    My Truong
    Claes Håkansson
    Makda HaileMichael
    Jonas Svensson
    Jimmy Lätt
    Karin Markenroth Bloch
    Roger Siemund
    Isabel Gonçalves
    Johan Wassélius
    BMC Medical Imaging, 21