Energy, exergy, economic, and environmental analysis of an integrated system of high-temperature heat pump and gas separation unit

被引:78
|
作者
Li, Xiaoqiong [1 ]
Zhang, Yufeng [1 ]
Fang, Lei [2 ]
Jin, Zhendong [3 ]
Zhang, Yan [1 ]
Yu, Xiaohui [4 ]
Ma, Xuelian [1 ]
Deng, Na [1 ]
Wu, Zhangxiang [1 ]
机构
[1] Tianjin Univ, Tianjin Key Lab Indoor Air Environm Qual Control, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, DK-2800 Lyngby, Denmark
[3] Shandong Chambroad Petrochem Co Ltd, Binzhou 256500, Shandong, Peoples R China
[4] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
关键词
Gas separation unit; High-temperature heat pump; Energy analysis; Exergy analysis; Economic analysis; Environmental analysis; EXERGOECONOMIC ANALYSIS; PERFORMANCE;
D O I
10.1016/j.enconman.2019.111911
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel integrated system consisting of a high-temperature heat pump providing 120-130 degrees C heat and a gas separation unit was developed to recover the industrial waste heat and replace the low-pressure steam used in traditional refinery process. An energy, exergy, economic, and environmental analysis was carried out to evaluate the performance of such integrated system according to its operational data of the project. Energy and exergy analyses provide an insight into the quantity and quality of the energy conversion of the integrated system. The results show that the coefficient, which evaluates the performance of the system in a stable operation mode, are 8.05 and 4.45 in the presence and absence of the waste heat recovery mechanism, respectively. The total exergy efficiency decreases from 34.57% to 33.03% in the ambient temperature range of - 10-40 degrees C. When an electricity price of 0.109 $/kW.h and a steam price of 22.361 $/t are considered, the annual net profit of the integrated system measures a minimum of 187.4*10(3) $/year and 169.8*10(3) $/year, the payback period measures a maximum of 2.21 years and 2 years, with and without considering the penalty cost induced by emission reductions. Assuming a 8000 h/year operating time, the reduction of CO2, SO2, and NOx emissions reaches 3348 t, 101 t, and 50 t, respectively. These results indicate that the integrated system operates with a high performance and provides significant economic and environmental benefits.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Thermodynamic Analysis of a Cascade Heat Pump Incorporated in High-Temperature Heating System
    Rudonja, Nedzad
    Gojak, Milan
    Zlatanovic, Ivan
    Todorovic, Ruzica
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2020, 66 (11): : 677 - 683
  • [42] Energy, exergy and economic analysis of an integrated ground source heat pump and anaerobic digestion system for Co-generation of heating, cooling and biogas
    Luo, Lulin
    Lu, Lidi
    Shen, Xuelian
    Chen, Jinhua
    Pan, Yang
    Wang, Yuchen
    Luo, Qing
    ENERGY, 2023, 282
  • [43] Economic and environmental analysis of the optimum design for the integrated system with air source heat pump and PVT
    Chae, Soowon
    Bae, Sangmu
    Nam, Yujin
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 48
  • [44] Energy, exergy, environmental and economic analysis of a solar-assisted heat pump-driven enclosed drying system with liquid desiccant dehumidification
    Su, Wei
    Li, Jiru
    Jin, Xu
    Liu, Zhongyan
    Yang, Di
    Zhang, Hao
    Zhang, Xiaosong
    ENERGY CONVERSION AND MANAGEMENT, 2024, 322
  • [45] Energy, exergy, economic, and environmental (4E) assessment of an experimental moderately-high-temperature heat pump for district heating and cooling networks
    Alarnaot-Alarnaout, Ghad
    Navarro-Esbri, Joaquin
    Barragan-Cervera, Angel
    Mota-Babiloni, Adrian
    ENERGY CONVERSION AND MANAGEMENT, 2025, 325
  • [46] The Exergy Analysis Of Gas Cooler In CO2 Heat Pump System
    Xie, Yingbai
    Wang, Zhichao
    Cui, Kuikui
    Zhang, Xuedong
    2011 2ND INTERNATIONAL CONFERENCE ON CHALLENGES IN ENVIRONMENTAL SCIENCE AND COMPUTER ENGINEERING (CESCE 2011), VOL 11, PT C, 2011, 11 : 1555 - 1560
  • [47] Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator
    Balaraman, Anand
    Rahman, Md Ashiqur
    Ziviani, Davide
    Warsinger, David M.
    ENTROPY, 2025, 27 (02)
  • [48] Exergy, economic and environmental evaluation of an optimized hybrid photovoltaic-geothermal heat pump system
    Kavian, Soheil
    Aghanajafi, Cyrus
    Mosleh, Hassan Jafari
    Nazari, Arash
    Nazari, Ashkan
    APPLIED ENERGY, 2020, 276 (276)
  • [49] Performance Evaluation of Chiller Unit with Gas Bearings Based on Energy, Exergy, Economic, and Environmental Analyses
    Gong, Jieming
    Ying, Shicheng
    Song, Junnan
    Liu, Guangbin
    Yang, Qichao
    Zhao, Yuanyang
    Li, Liansheng
    Wang, Jing
    JOURNAL OF ENERGY ENGINEERING, 2025, 151 (02)
  • [50] HIGH-TEMPERATURE HEAT-PUMP BY BINARY REFRIGERATING SYSTEM
    SHIBATA, E
    NAKAKOSHI, T
    MINATO, K
    SHARP TECHNICAL JOURNAL, 1987, (37): : 83 - 88