Energy, exergy, economic, and environmental analysis of an integrated system of high-temperature heat pump and gas separation unit

被引:78
|
作者
Li, Xiaoqiong [1 ]
Zhang, Yufeng [1 ]
Fang, Lei [2 ]
Jin, Zhendong [3 ]
Zhang, Yan [1 ]
Yu, Xiaohui [4 ]
Ma, Xuelian [1 ]
Deng, Na [1 ]
Wu, Zhangxiang [1 ]
机构
[1] Tianjin Univ, Tianjin Key Lab Indoor Air Environm Qual Control, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, DK-2800 Lyngby, Denmark
[3] Shandong Chambroad Petrochem Co Ltd, Binzhou 256500, Shandong, Peoples R China
[4] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
关键词
Gas separation unit; High-temperature heat pump; Energy analysis; Exergy analysis; Economic analysis; Environmental analysis; EXERGOECONOMIC ANALYSIS; PERFORMANCE;
D O I
10.1016/j.enconman.2019.111911
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel integrated system consisting of a high-temperature heat pump providing 120-130 degrees C heat and a gas separation unit was developed to recover the industrial waste heat and replace the low-pressure steam used in traditional refinery process. An energy, exergy, economic, and environmental analysis was carried out to evaluate the performance of such integrated system according to its operational data of the project. Energy and exergy analyses provide an insight into the quantity and quality of the energy conversion of the integrated system. The results show that the coefficient, which evaluates the performance of the system in a stable operation mode, are 8.05 and 4.45 in the presence and absence of the waste heat recovery mechanism, respectively. The total exergy efficiency decreases from 34.57% to 33.03% in the ambient temperature range of - 10-40 degrees C. When an electricity price of 0.109 $/kW.h and a steam price of 22.361 $/t are considered, the annual net profit of the integrated system measures a minimum of 187.4*10(3) $/year and 169.8*10(3) $/year, the payback period measures a maximum of 2.21 years and 2 years, with and without considering the penalty cost induced by emission reductions. Assuming a 8000 h/year operating time, the reduction of CO2, SO2, and NOx emissions reaches 3348 t, 101 t, and 50 t, respectively. These results indicate that the integrated system operates with a high performance and provides significant economic and environmental benefits.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Energy, exergy, economic, and environmental analysis for methyl acetate hydrolysis process with heat integrated technology used
    Chen, Hao
    Li, Xingang
    He, Lin
    Cong, Haifeng
    ENERGY CONVERSION AND MANAGEMENT, 2020, 216
  • [22] Energy, exergy, economic, and environmental analysis for methyl acetate hydrolysis process with heat integrated technology used
    Chen, Hao
    Li, Xingang
    He, Lin
    Cong, Haifeng
    Energy Conversion and Management, 2021, 216
  • [23] Operating characterization and performance optimization of high-temperature heat pumps: A comparative energy, economic and environmental analysis
    Yang, Lingxiao
    Wang, Xin
    Xu, Bo
    Chen, Zhenqian
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [24] An experimental energy performance investigation and economic analysis on a cascade heat pump for high-temperature water in cold region
    Xu, Liangfeng
    Li, Enteng
    Xu, Yingjie
    Mao, Ning
    Shen, Xi
    Wang, Xinlei
    RENEWABLE ENERGY, 2020, 152 : 674 - 683
  • [25] Comparative energy, exergy, economic, and environmental (4E) analysis and optimization of two high-temperature Kalina cycles integrated with thermoelectric generators for waste heat recovery from a diesel engine
    Sohrabi, Arvin
    Asgari, Nima
    Imran, Muhammad
    Shahzad, Muhammad Wakil
    ENERGY CONVERSION AND MANAGEMENT, 2023, 291
  • [26] Proposal and assessment of a novel combined heat and power system: Energy, exergy, environmental and economic analysis
    Ebrahimi-Moghadam, Amir
    Moghadam, Ali Jabari
    Farzaneh-Gord, Mahmood
    Aliakbari, Karim
    ENERGY CONVERSION AND MANAGEMENT, 2020, 204
  • [27] Exergy, Economic and Environmental Analyses of Gas Turbine Inlet Air Cooling with a Heat Pump Using a Novel System Configuration
    Yazdi, Mohammad Reza Majdi
    Aliehyaei, Mehdi
    Rosen, Marc A.
    SUSTAINABILITY, 2015, 7 (10) : 14259 - 14286
  • [28] Energy, exergy, exergoeconomic and environmental (4E) analysis of cascade heat pump, recuperative heat pump and carbon dioxide heat pump with different temperature lifts
    Wu, Jinxing
    Sun, Shoujun
    Song, Qinglu
    Sun, Dandan
    Wang, Dechang
    Li, Jiaxu
    RENEWABLE ENERGY, 2023, 207 : 407 - 421
  • [29] Energy and exergy analysis of a combined ground source heat pump system
    Ozturk, M. (muratozturk@sdu.edu.tr), 1600, Elsevier Ltd (73):
  • [30] Energy and exergy analysis of a ground source (geothermal) heat pump system
    Hepbasli, A
    Akdemir, O
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (05) : 737 - 753