Comparing Changes in Corneal Astigmatism Using Scheimpflug Camera after Epiblepharon Correction Surgery

被引:0
|
作者
Lee, Ji Hye [1 ]
Kim, Sung Eun [1 ]
Byun, Yong-Soo [1 ]
Yang, Suk-Woo [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul, South Korea
来源
关键词
Epiblepharon of Upper Lid; Astigmatism; Corneal curvature; Scheimpflug camera;
D O I
10.3341/jkos.2022.63.3.221
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the changes in corneal astigmatism before and after epiblepharon correction surgery with a Scheimpflug camera. Methods: From April, 2019, to June, 2020, 48 eyes of 24 patients underwent epiblepharon correction surgery. The patients were divided into two subgroups by age and their best corrected visual acuity (BCVA) and corneal anterior and posterior astigmatism were compared before and after correction surgery. Results: There was no difference in BCVA after the correction surgery. To assess the changes in the keratometric value and astigmatism after epiblepharon surgery, a Scheimpflug camera was used. The anterior flat and mean keratometry changed from 42.10 +/- 1.46 to 42.43 +/- 1.10 D (p = 0.035) and from 42.97 +/- 1.26 to 43.21 +/- 1.15 D (p = 0.012), respectively, while the posterior corneal astigmatism changed from 0.44 +/- 0.31 to 0.35 +/- 0.17 D (p = 0.047). There were no significant changes in steep keratometry (p = 0.191) or anterior corneal astigmatism (p = 0.126). Conclusions: There were significant changes after epiblepharon correction surgery in anterior keratometry reading and posterior corneal astigmatism.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [41] Analysis of Changes in Anterior, Posterior and Total Corneal Astigmatism after On-Axis Cataract Surgery
    Lee, Kee Il
    Park, Yu Li
    Kim, Hyun Seung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (01): : 25 - 35
  • [42] The predictive accuracy of Barrett toric calculator using measured posterior corneal astigmatism derived from swept source-OCT and Scheimpflug camera
    Xiaotong Yang
    Yuanfeng Jiang
    Song Lin
    Xiaomei Bai
    Yufan Yin
    FangYu Zhao
    Jun Yang
    Fang Tian
    Xiteng Chen
    Jingli Liang
    Shaochong Bu
    Eye, 2024, 38 : 132 - 137
  • [43] The correction of corneal astigmatism with silicone toric IOLs at the time of cataract surgery
    Manasses, D
    Govan, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [44] Comparing Change in Anterior Curvature after Corneal Cross-Linking Using Placido and Scheimpflug Imaging
    Lang, Paul
    Thulasi, Praneetha
    Khandelwal, Sumitra
    Randleman, James Bradley
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [45] CHANGES IN VECTOR ASTIGMATISM AFTER SUPEROTEMPORAL VERSUS TEMPORAL CLEAR CORNEAL INCISION CATARACT SURGERY
    Zhao, Zhennan
    Fan, Qi
    Jiang, Yongxiang
    Lu, Yi
    CLINICAL AND INVESTIGATIVE MEDICINE, 2022, 45 (04): : E16 - E24
  • [46] The predictive accuracy of Barrett toric calculator using measured posterior corneal astigmatism derived from swept source-OCT and Scheimpflug camera
    Yang, Xiaotong
    Jiang, Yuanfeng
    Lin, Song
    Bai, Xiaomei
    Yin, Yufan
    Zhao, FangYu
    Yang, Jun
    Tian, Fang
    Chen, Xiteng
    Liang, Jingli
    Bu, Shaochong
    EYE, 2024, 38 (01) : 132 - 137
  • [47] Induced astigmatism after corneal suture removal after cataract surgery
    Loriaut, P.
    Kaswin, G.
    Rousseau, A.
    Meziani, L.
    M'Nafek, N.
    Pogorzalek, N.
    Labetoulle, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2014, 37 (03): : 226 - 230
  • [48] Cataract surgery with toric intraocular lens for correction of high corneal astigmatism
    Iovieno, Alfonso
    Yeung, Sonia N.
    Lichtinger, Alejandro
    Alangh, Manreet
    Slomovic, Allan R.
    Rootman, David S.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2013, 48 (04): : 246 - 250
  • [49] Agreement between total corneal astigmatism calculated by vector summation and total corneal astigmatism measured by ray tracing using Galilei double Scheimpflug analyzer
    Feizi, Sepehr
    Delfazayebaher, Siamak
    Ownagh, Vahid
    Sadeghpour, Fatemeh
    JOURNAL OF OPTOMETRY, 2018, 11 (02) : 113 - 120
  • [50] Intraocular lens power calculations using a Scheimpflug camera to measure corneal power
    Xu, K.
    Hao, Y.
    Qi, H.
    BIOTECHNIC & HISTOCHEMISTRY, 2014, 89 (05) : 348 - 354