Different methods of organ equivalent dose scoring in Monte Carlo neutron dose calculations

被引:0
|
作者
Jarlskog, C. Zacharatou
Lee, C.
Bolch, W.
Xu, X.
Paganetti, H.
机构
[1] Massachusetts Gen Hosp, Boston, MA 02114 USA
[2] MD Anderson Canc Ctr, Orlando, FL USA
[3] Univ Florida, Gainesville, FL USA
[4] Rensselaer Polytech Inst, Troy, NY USA
关键词
D O I
10.1118/1.2760816
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In proton therapy, neutrons are generated in treatment head and patient. Monte Carlo simulations are widely used to study secondary neutrons. Neutron quality factors are defined conservatively and do not necessarily take into account that dose might be deposited by secondary particles generated by neutrons, which might have a different quality factor. The purpose of this study was to assess how the organ equivalent neutron dose depends on different scoring methods. Method and Materials: Six voxelized phantoms representing patients of different age have been implemented into our Monte Carlo code. Organ doses, D, were combined with weighting factors to calculate organ equivalent doses, H. Method 1 is based on: [formula omitted] (Dppi, Dep, Dother:D for different proton energy intervals, D from electrons originating from protons and D from particles other than protons or electrons, respectively; Hpnw, Henw: event‐by‐event wR‐weighted energy deposition by protons originating from neutrons and by electrons originating from neutrons, respectively; wR: neutron weighting factors weighed by the fluence spectrum of the neutrons entering the organ). Method 2 is based on the products of the wR value and the sum of doses deposited by all particles: [formula omitted]: organ doses deposited by protons (electrons) originating from neutrons, respectively). Method 3 is a variation of method 1 by replacing the newly proposed ICRP neutron radiation factors by its current definition. Results: We found significant relative differences in organ equivalent dose between methods 1 and 2, i.e. 20–50%. We found an increasing discrepancy with increasing age of the phantom but no dependence on the distance of the organ from the PTV. Of all methods, method 1 gives the highest values of organ equivalent dose. Conclusion: When calculating neutron doses using Monte Carlo simulations, the organ equivalent dose depends significantly on the applied scoring method. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2437 / 2437
页数:1
相关论文
共 50 条
  • [41] Effect of voxel size on Monte Carlo dose calculations
    Qin, L
    Yang, J
    Li, J
    Chen, L
    Price, R
    Ma, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1883 - 1883
  • [42] MONTE CARLO CALCULATIONS OF GAMMA-RAY DOSE
    BROWNELL, GL
    REDDY, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 616 - &
  • [43] New calculations of neutron kerma coefficients and dose equivalent
    Liu, Zhenzhou
    Chen, Jinxiang
    JOURNAL OF RADIOLOGICAL PROTECTION, 2008, 28 (02) : 185 - 193
  • [44] ANALYTICAL AND MONTE CARLO DOSE CALCULATIONS FOR PARTICLE THERAPY
    Szymanowski, H.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S65 - S65
  • [45] Monte Carlo dose calculations for phantoms with hip prostheses
    Bazalova, M.
    Coolens, C.
    Cury, F.
    Childs, P.
    Beaulieu, L.
    Verhaegen, F.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [46] EQUIVALENT SPHERICAL-SHIELD-NEUTRON-DOSE CALCULATIONS
    RUSSELL, GJ
    ROBINSON, H
    ADVANCED NEUTRON SOURCES 1988, 1989, 97 : 803 - 807
  • [47] CALCULATIONS OF EFFECTIVE DOSE EQUIVALENT, AMBIENT DOSE EQUIVALENT AND INDIVIDUAL DOSE EQUIVALENT FOR A SET OF REFERENCE NEUTRON-SPECTRA AND FIELD GEOMETRIES
    BARTLETT, DT
    GREENHALGH, JR
    HEALTH PHYSICS, 1986, 50 (04): : 548 - 550
  • [48] Validation of Acuros XB Dose Calculations in SBRT Lung Planning with Monte Carlo Methods
    Bush, K.
    Wang, L.
    Mok, E.
    MEDICAL PHYSICS, 2012, 39 (06) : 3816 - 3817
  • [49] Peregrine Monte Carlo dose calculations for radiotherapy using clinically realistic neutron and proton beams
    Cox, LJ
    Bohm, TD
    Chadwick, MB
    DeLuca, PM
    Siebers, JV
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, VOL 59, PT 1 AND 2, 1997, 59 : 1693 - 1699
  • [50] Monte Carlo Calculations of Selected Dose Components in a Head Model for Boron Neutron Capture Therapy
    Tyminska, Katarzyna
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2007, 13 (03) : 127 - 137