Different methods of organ equivalent dose scoring in Monte Carlo neutron dose calculations

被引:0
|
作者
Jarlskog, C. Zacharatou
Lee, C.
Bolch, W.
Xu, X.
Paganetti, H.
机构
[1] Massachusetts Gen Hosp, Boston, MA 02114 USA
[2] MD Anderson Canc Ctr, Orlando, FL USA
[3] Univ Florida, Gainesville, FL USA
[4] Rensselaer Polytech Inst, Troy, NY USA
关键词
D O I
10.1118/1.2760816
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In proton therapy, neutrons are generated in treatment head and patient. Monte Carlo simulations are widely used to study secondary neutrons. Neutron quality factors are defined conservatively and do not necessarily take into account that dose might be deposited by secondary particles generated by neutrons, which might have a different quality factor. The purpose of this study was to assess how the organ equivalent neutron dose depends on different scoring methods. Method and Materials: Six voxelized phantoms representing patients of different age have been implemented into our Monte Carlo code. Organ doses, D, were combined with weighting factors to calculate organ equivalent doses, H. Method 1 is based on: [formula omitted] (Dppi, Dep, Dother:D for different proton energy intervals, D from electrons originating from protons and D from particles other than protons or electrons, respectively; Hpnw, Henw: event‐by‐event wR‐weighted energy deposition by protons originating from neutrons and by electrons originating from neutrons, respectively; wR: neutron weighting factors weighed by the fluence spectrum of the neutrons entering the organ). Method 2 is based on the products of the wR value and the sum of doses deposited by all particles: [formula omitted]: organ doses deposited by protons (electrons) originating from neutrons, respectively). Method 3 is a variation of method 1 by replacing the newly proposed ICRP neutron radiation factors by its current definition. Results: We found significant relative differences in organ equivalent dose between methods 1 and 2, i.e. 20–50%. We found an increasing discrepancy with increasing age of the phantom but no dependence on the distance of the organ from the PTV. Of all methods, method 1 gives the highest values of organ equivalent dose. Conclusion: When calculating neutron doses using Monte Carlo simulations, the organ equivalent dose depends significantly on the applied scoring method. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2437 / 2437
页数:1
相关论文
共 50 条
  • [21] MONTE-CARLO CALCULATIONS OF PARTICLE FLUENCES AND NEUTRON EFFECTIVE DOSE RATES IN THE ATMOSPHERE
    Matthia, Daniel
    Sihver, Lembit
    Meier, Matthias
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (02) : 222 - 228
  • [22] Preliminary Monte Carlo calculations of secondary neutron dose from 18 MV IMRT
    Ferenci, M
    Howell, R
    Hertel, N
    MEDICAL PHYSICS, 2004, 31 (06) : 1909 - 1910
  • [23] MONTE CARLO CALCULATIONS OF LUNG DOSE IN ORNL PHANTOM FOR BORON NEUTRON CAPTURE THERAPY
    Krstic, D.
    Markovic, V. M.
    Jovanovic, Z.
    Milenkovic, B.
    Nikezic, D.
    Atanackovic, J.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 269 - 273
  • [24] The effect of geometrical and scoring voxel dimensions on accuracy and efficacy of Monte Carlo dose calculations for IMRT
    De Smedt, B
    Vanderstraeten, B
    Reynaert, N
    De Neve, W
    Thierens, H
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S149 - S149
  • [25] The validation of organ dose calculations using voxel phantoms and Monte Carlo methods applied to point and water immersion sources
    Hunt, JG
    da Silva, FCA
    Mauricio, CLP
    dos Santos, DS
    RADIATION PROTECTION DOSIMETRY, 2004, 108 (01) : 85 - 89
  • [26] Dose in multi-slice cardiac CT: Assessment of organ and effective dose values with Monte Carlo methods
    Schmidt, B
    Ulzheimer, S
    Kalender, WA
    RADIOLOGY, 2001, 221 : 414 - 414
  • [27] Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design
    Titt, Uwe
    Pera, Enzo
    Gillin, Michael T.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2020, 6 (04) : 29 - 37
  • [28] Determination of dose from CT examinations: Estimating organ dose using Monte Carlo-based methods
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2538 - 2539
  • [29] Monte Carlo study of the neutron ambient dose equivalent at the heavy ion medical machine in Wuwei
    Sheng-Cong Huang
    Hui Zhang
    Kai Bai
    Ying Luo
    Hai-Jun Mao
    Zhong-Ying Dai
    NuclearScienceandTechniques, 2022, 33 (09) : 113 - 127
  • [30] A Monte Carlo approach to estimate organ dose uncertainty
    Taulbee, TD
    Neton, JW
    HEALTH PHYSICS, 2003, 84 (06): : S212 - S213