Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

被引:24
|
作者
Zhang, Zina [1 ]
Thomas, Logan William [1 ]
Leu, Szu-Yen [1 ]
Carter, Steven [1 ]
Garg, Sumit [1 ]
机构
[1] Univ Calif Irvine, Gavin Herbert Eye Inst, Dept Ophthalmol, 850 Hlth Sci Rd, Irvine, CA 92617 USA
关键词
Intraocular lens master; intraoperative wavefront aberrometry; optiwave refractive analysis; EYES;
D O I
10.4103/ijo.IJO_163_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. Methods: Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refractive analysis (ORA) system. Analysis was performed to determine the accuracy of monofocal IOL power prediction and postoperative manifest refraction at 1 month of the ORA versus IOLMaster. Results: Two hundred and ninety-five eyes reviewed, 61 had only preoperative IOLMaster measurements and 234 had both IOLMaster and ORA measurements. Of these 234 eyes, 6 were excluded, 107 had the same recommended IOL power by ORA and IOLMaster. Sixty-four percent of these eyes were within +/- 0.5D. 95 eyes had IOL power implantation based on ORA instead of IOLMaster. Seventy percent of these eyes were within +/- 0.5D of target refraction. 26 eyes had IOL power chosen based on IOLMaster predictions instead of ORA. Sixty-five percent were within +/- 0.5D. In the group with IOLMaster without ORA measurements, 80% of eyes were within +/- 0.5D of target refraction. The absolute error was statistically smaller in those eyes where the ORA and IOLMaster recommended the same IOL power based on preoperative target refraction compared to instances in which IOL selection was based on ORA or IOLMaster alone. Neither prediction errors were statistically different between the ORA and IOLMaster alone. Conclusion: Intraoperative wavefront aberrometry with the ORA system provides postoperative refractive results comparable to conventional biometry with the IOLMaster for monofocal IOL selection.
引用
收藏
页码:813 / 817
页数:5
相关论文
共 50 条
  • [21] Biometry and Intraocular Lens Power Calculation by Combined Scheimpflug-Placido Disc versus Optical Interferometry Devices
    Juliane, Mehlan
    Anne-Isabel, Lehman
    Myriam, Cichocki
    Vasyl, Druchkiv
    Toam, Katz
    Linke, Stephan J.
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2022, 17 (04) : 453 - 461
  • [22] Optical Biometry-Based Intraocular Lens Calculation and Refractive Outcomes after Phacovitrectomy for Rhegmatogenous Retinal Detachment and Epiretinal Membrane
    Shiraki, Nobuhiko
    Wakabayashi, Taku
    Sakaguchi, Hirokazu
    Nishida, Kohji
    SCIENTIFIC REPORTS, 2018, 8
  • [23] Optical Biometry-Based Intraocular Lens Calculation and Refractive Outcomes after Phacovitrectomy for Rhegmatogenous Retinal Detachment and Epiretinal Membrane
    Nobuhiko Shiraki
    Taku Wakabayashi
    Hirokazu Sakaguchi
    Kohji Nishida
    Scientific Reports, 8
  • [24] Refractive outcomes of intraocular lens power calculation using different corneal power measurements with a new optical biometer
    Savini, Giacomo
    Negishi, Kazuno
    Hoffer, Kenneth J.
    Lomoriello, Domenico Schiano
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (06): : 701 - 708
  • [25] Intraoperative aberrometry vs modern preoperative formulas in predicting intraocular lens power
    Raufi, Nikolas
    James, Charlene
    Kuo, Anthony
    Vann, Robin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (06): : 857 - 861
  • [26] Intraoperative refraction for intraocular lens power calculation
    Biancardi, Ana Luiza
    Walsh, Aileen
    Crema, Armando Stefano
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2011, 70 (02) : 118 - 121
  • [27] Biometry and intraocular lens power calculation for cataract surgery: an update
    Findl, O.
    SPEKTRUM DER AUGENHEILKUNDE, 2007, 21 (02) : 90 - 93
  • [28] Modern preoperative intraocular lens calculation is better than intraoperative aberrometry for normal eyes
    Runde, Matt R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02): : 253 - 254
  • [29] The end of preoperative biometry? Calculating intraocular lens power 'on the table' with two new intraoperative Hartmann-Shack aberrometry derived formulae
    Huelle, Jan O.
    Druchkiv, Vasyl
    Habib, Nabil
    Richard, Gisbert
    Katz, Toam
    Linke, Stephan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [30] Comparison of Preoperative Intraocular Lens Power Selection Methods to Intraoperative Aberrometry in Short Eyes
    Sudhakar, Shruti
    Hill, Darren
    Hill, Christopher
    Scott, Ingrid U.
    Ernst, Brett
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)