Expansion and fixation properties of a new braided biodegradable urethral stent:: An experimental study in the rabbit

被引:24
|
作者
Vaajanen, A [1 ]
Nuutinen, JP
Isotalo, T
Törmälä, P
Tammela, TLJ
Talja, M
机构
[1] Tampere Univ Hosp, Dept Urol, Tampere, Finland
[2] Univ Tampere, Sch Med, FIN-33101 Tampere, Finland
[3] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
[4] Paijat Hame Cent Hosp, Dept Surg, Lahti, Finland
来源
JOURNAL OF UROLOGY | 2003年 / 169卷 / 03期
关键词
urethra; stents; rabbits; polymers; urethral stricture;
D O I
10.1097/01.ju.0000049229.12451.13
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Biodegradable spiral urethral stents have been used with favorable results combined with thermal treatments of the prostate and for recurrent urethral strictures but the configuration of the helical spiral is not ideal. We developed a new tubular mesh configuration for the biodegradable urethral stent and evaluated its expansion and locking properties in the rabbit urethra. Materials and Methods: The stents were made of self-reinforced polylactic acid polymer (Bionx Implants, Ltd., Tampere, Finland) blended with BaSO4 (Alfa Chem, New York, New York) to achieve radiopacity. Two braiding patterns, that is I over 1 and 2 over 2 + 1, were used to produce a tubular mesh structure. Stainless steel stents (pattern I over 1) served as controls. The stents were inserted into the posterior urethra of 27 male rabbits. The animals were sacrified after 1 week, 1 and 6 months, respectively. X-rays were done immediately after stent insertion and at sacrifice. Longitudinal movement and expansion were assessed on the x-rays. Results: All stents maintained position in the urethra without fixation. Macroscopic disorientation of the structure of the 2 over 2 + 1 braided self-reinforced polylactic acid polymer stents began before 1 month, while 1 over 1 braided stents retained their construction. At 6 months 3 of 6 biodegradable stents were degraded. Average longitudinal movement was 2 mm. (range 1 to 3) in the 1 over 1 self-reinforced polylactic acid polymer group, 2 mm. (range 0 to 7) in the 2 over 2 + 1 polylactic acid group and 3 mm. (range 3 to 3) in controls at 1 month. Conclusions: Biodegradable polymers are suitable materials for braided urethral stents. The expansion properties of the 2 braiding models tested in this study sufficed to fix the stents in situ in the prostatic urethra. However, the 1 over 1 braiding pattern was superior to the 2 over 2 + 1 pattern, in that it retained its macroscopic construction until the degradation of single self-reinforced polylactic acid polymer fibers.
引用
收藏
页码:1171 / 1174
页数:4
相关论文
共 50 条
  • [21] New biodegradable drug-eluting stents for urethral strictures in a rabbit model
    Wang, Zhong-Xin
    Hong, Bao-Fa
    Zhang, Xu
    Fu, Wei-Jun
    Cui, Fu-Zhai
    Hu, Kun
    JOURNAL OF BIOACTIVE AND COMPATIBLE POLYMERS, 2011, 26 (01) : 89 - 98
  • [22] Biodegradable polydioxanone stent as a new treatment strategy for tracheal stenosis in a rabbit model
    Kawahara, Insu
    Ono, Shigeru
    Maeda, Kosaku
    JOURNAL OF PEDIATRIC SURGERY, 2016, 51 (12) : 1967 - 1971
  • [23] A pilot study of a novel biodegradable magnesium alloy airway stent in a rabbit model
    Xue, Bangde
    Liang, Beibei
    Yuan, Guangyin
    Zhu, Limin
    Wang, Hao
    Lu, Zhaohui
    Xu, Zhiwei
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 117 : 88 - 95
  • [24] Biodegradable braided poly(lactic-co-glycolic acid) urethral stent combined with dutasteride in the treatment of acute urinary retention due to benign prostatic enlargement: a pilot study
    Kotsar, Andres
    Isotalo, Taina
    Juuti, Hanne
    Mikkonen, Joonas
    Leppiniemi, Jenni
    Hanninen, Venla
    Kellomaki, Minna
    Talja, Martti
    Tammela, Teuvo L. J.
    BJU INTERNATIONAL, 2009, 103 (05) : 626 - 629
  • [25] Biodegradable urethral stents seeded with autologous urethral epithelial cells in the treatment of post-traumatic urethral stricture: a feasibility study in a rabbit model
    Fu, Wei-Jun
    Zhang, Xu
    Zhang, Bing-Hong
    Zhang, Peng
    Hong, Bao-Fa
    Gao, Jiang-Ping
    Meng, Bo
    Kun, Hu
    Cui, Fu-Zhai
    BJU INTERNATIONAL, 2009, 104 (02) : 263 - 268
  • [26] BIODEGRADABLE PLATE FIXATION OF RABBIT FEMORAL-SHAFT OSTEOTOMIES - A COMPARATIVE-STUDY
    HANAFUSA, S
    MATSUSUE, Y
    YASUNAGA, T
    YAMAMURO, T
    OKA, M
    SHIKINAMI, Y
    IKADA, Y
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (315) : 262 - 271
  • [27] The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study
    Resch, T
    Malina, M
    Lindblad, B
    Malina, J
    Brunkwall, J
    Ivancev, K
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) : 190 - 195
  • [28] EXPERIMENTAL STUDY OF A NEW BIODEGRADABLE AND HEPARINE-COATED URETERAL STENT DESIGN FOR THE ENDOUROLOGIC TREATMENT OF URETERAL STRICTURE
    De La Cruz Conty, J. E.
    Morcillo, E.
    Brime, R.
    Lopez De Alda, A.
    Moreno, J.
    Sanchez-Margallo, F. M.
    Soria, F.
    BRITISH JOURNAL OF SURGERY, 2018, 105 : 9 - 10
  • [29] Experimental assessment of new stent technologies: Validation of a comparative paired rabbit iliac artery study model
    Robert, R
    Rioufol, G
    Finet, G
    Cottin, Y
    Tabib, A
    Zeller, M
    Wolf, JE
    Lievre, M
    Bricca, G
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 70B (02) : 303 - 310
  • [30] EXPERIMENTAL STUDY OF THE HEPARIN COATING OF THE BIODEGRADABLE URETERAL STENT BRAIDSTENT IN LASER ENDOURETEROTOMY
    De La Cruz, J. E.
    Paniagua, R.
    Fernandez Aparicio, T.
    Resel-Folkersma, L.
    Rioja, J.
    Lopez-Alda, A.
    Sanchez-Margallo, F. M.
    Soria, F.
    BRITISH JOURNAL OF SURGERY, 2019, 106 : 6 - 7