This paper presents the performance of a commercial lead quality monitoring library (LQMLib, Schiller AG) for detection of reversals between 12-lead ECG cables with matching colors and proposes methods for improvements, where necessary. The study is performed on a large 12-lead ECG database with 1331 chest pain patients (646 training, 685 test recordings) and ECGs from 29 volunteers with swapped red, yellow, green, black and all unicolor cables. Relying on assessment of inter-lead correlations over continuous 4s episodes, LQMLib without adjustments achieves Se>97% for all unicolor cable reversals, except RC1 (Se=29%) and NC5 (Se=88%). The proposed additional analyses improve RC1 and NC5 swap detection by 63% points and 7% points, respectively.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] The 12-lead ECG: a continuous reference for the cardiologist
    Boriani, Giuseppe
    Vitolo, Marco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (07) : 459 - 463
  • [42] Prehospital 12-lead ECG diagnostic programs
    Urban, MJ
    Edmondson, DA
    Aufderheide, TP
    EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2002, 20 (04) : 825 - +
  • [43] A Portable 12-Lead ECG Acquisition System
    Sun, Cheng
    Liao, Jingsheng
    Wang, Gang
    Li, Baopu
    Meng, Max Q-H
    2013 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2013, : 368 - 373
  • [44] Prehospital 12-lead ECG: Efficacy or effectiveness?
    Swor, Robert
    Hegerberg, Stacey
    McHugh-McNally, Ann
    Goldstein, Mark
    McEachin, Christine C.
    PREHOSPITAL EMERGENCY CARE, 2006, 10 (03) : 374 - 377
  • [45] Shark Fin Sign on a 12-Lead ECG
    Macherey-Meyer, Sascha
    Terporten, Johannes
    Adler, Christoph
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2024, 121 (20):
  • [46] A New 12-Lead ECG Prognostic Score
    Soofi, Muhammad
    Jain, Nikhil A.
    Myers, Jonathan
    Froelicher, V. F.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2015, 20 (06) : 554 - 560
  • [47] Improved spatial sampling of ECG potentials on the body surface by repositioning electrodes from the standard 12-lead ECG
    Kors, JA
    Van Heipen, G
    COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 29 - 32
  • [48] A novel method for 12-lead ECG reconstruction
    EPMoghaddam, Dorsa
    Banta, Anton
    Post, Allison
    Razavi, Mehdi
    Aazhang, Behnaam
    FIFTY-SEVENTH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS & COMPUTERS, IEEECONF, 2023, : 1054 - 1058
  • [49] Evaluation of the Accuracy of ECG Captured by CardioChip through Comparison of Lead I Recording to a Standard 12-Lead ECG Recording Device
    Lo, Chi-In
    Chang, Sheng-Shiung
    Tsai, Jui-Peng
    Kuo, Jen-Yuan
    Chen, Ying-Ju
    Huang, Ming-Yuan
    Lee, Chao-Hsiung
    Sung, Kuo-Tzu
    Hung, Chung-Lieh
    Hou, Charles Jia-Yin
    Lai, Edward
    Yeh, Hung-I
    Chang, Wen-Ling
    Chang, Wen-Han
    ACTA CARDIOLOGICA SINICA, 2018, 34 (02) : 144 - 151
  • [50] CHARACTERISTIC FINDINGS ON THE STANDARD 12-LEAD ECG IN PATIENTS WITH THE FASCICULOVENTRICULAR MAHAIM FIBER
    MIYAGUCHI, K
    TSUZUKI, J
    YOKOTA, M
    HAYASHI, H
    JOURNAL OF ELECTROCARDIOLOGY, 1992, 25 (04) : 253 - 261