Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients

被引:211
|
作者
Reuter, DA
Bayerlein, J
Goepfert, MSG
Weis, FC
Kilger, E
Lamm, P
Goetz, AE
机构
[1] Univ Munich, Dept Anesthesiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Cardiac Surg, D-81377 Munich, Germany
关键词
diagnostic techniques; cardiovascular; preload; fluid responsiveness; cardiac output; pulse contour analysis; mechanical ventilation;
D O I
10.1007/s00134-003-1649-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Real-time measurement of stroke volume variation by arterial pulse contour analysis (SVV) is useful in predicting volume responsiveness and monitoring volume therapy in mechanically ventilated patients. This study investigated the influence of the depth of tidal volume (V-t) on SVV both during the state of fluid responsiveness and after fluid loading in mechanically ventilated patients. Design and setting: Prospective study in a university hospital, adult cardiac surgery intensive care unit. Patients and participants: 20 hemodynamically stable patients immediately after cardiac surgery. Interventions: Stepwise fluid loading using colloids until stroke volume index (SVI) did not increase by more than 10%. Before and after fluid loading V-t was varied (5, 10, and 15 ml/kg body weight) in random order. Measurements and results: Pulse contour SVV was measured before and after volume loading at the respective V-t values. Thirteen patients responded to fluid loading with an increase in SVI greater than 10%, which confirmed volume responsiveness at baseline measurements. These were included in further analysis. During volume responsiveness SVV at V-t of 5 ml/kg (7+/-0.7%) and SVV at V-t of 15 ml/kg (21+/-2.5%) differed significantly from that at V-t of 10 ml/kg (15+/-2.1%). SVV was correlated significantly with the magnitude of V-t. After volume resuscitation SVV at the respective V-t was significantly reduced; further, SVV at V-t of 5 ml/kg(-1) (5.3+/-0.6%) and 15 ml/kg (16.2+/-2.0%) differed significantly from that at V-t of 10 ml/kg (10.2+/-1.0%). SVV and depth of V-t were significantly related. Conclusions: In addition to intravascular volume status SVV is affected by the depth of tidal volume under mechanical ventilation. This influence must be regarded when using SVV for functional preload monitoring.
引用
收藏
页码:476 / 480
页数:5
相关论文
共 50 条
  • [1] Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients
    Daniel A. Reuter
    Julian Bayerlein
    Matthias S. G. Goepfert
    Florian C. Weis
    Erich Kilger
    Peter Lamm
    Alwin E. Goetz
    Intensive Care Medicine, 2003, 29 : 476 - 480
  • [2] Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients
    Wiesenack, C
    Prasser, C
    Rödig, G
    Keyl, C
    ANESTHESIA AND ANALGESIA, 2003, 96 (05): : 1254 - 1257
  • [3] Functional preload monitoring by arterial pulse contour analysis: Influence of tidal volume on left ventricular stroke volume variations
    Reuter, DA
    Bayerlein, J
    Goepfert, M
    Weis, FC
    Kilger, E
    Goetz, AE
    CRITICAL CARE MEDICINE, 2002, 30 (12) : A19 - A19
  • [4] Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated Patients
    De Backer, Daniel
    Taccone, Fabio Silvio
    Holsten, Roland
    Ibrahimi, Fayssal
    Vincent, Jean-Louis
    ANESTHESIOLOGY, 2009, 110 (05) : 1092 - 1097
  • [5] Is the pulse pressure variation a good predictor of fluid responsiveness in mechanically ventilated patients with low tidal volume?
    C Costa
    S Vieira
    G Friedman
    L Fialkow
    Critical Care, 13 (Suppl 1):
  • [6] Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    Biais, M.
    Nouette-Gaulain, K.
    Cottenceau, V.
    Revel, P.
    Sztark, F.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) : 761 - 768
  • [7] Tidal volume influences left ventricular stroke volume variations
    Reuter, DA
    Bayerlein, JA
    Goepfert, M
    Weis, FC
    Kilger, E
    Goetz, AE
    INTENSIVE CARE MEDICINE, 2002, 28 : S19 - S19
  • [8] LEFT VENTRICULAR STROKE VOLUME MEASURED BY ULTRASOUND
    FEIGENBAUM, H
    NASSER, WK
    ROSS, E
    ELLIOTT, WC
    CIRCULATION, 1969, 40 (4S3) : II79 - +
  • [9] Validation of pulse contour derived stroke volume variation
    Ahmed, I.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (05) : 745 - 746
  • [10] Reliability of measured tidal volume in mechanically ventilated young pigs with normal lungs
    Heulitt, MJ
    Holt, SJ
    Thurman, TL
    Hall, RA
    Jo, CH
    Simpson, P
    INTENSIVE CARE MEDICINE, 2005, 31 (09) : 1255 - 1261