Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients

被引:211
|
作者
Reuter, DA
Bayerlein, J
Goepfert, MSG
Weis, FC
Kilger, E
Lamm, P
Goetz, AE
机构
[1] Univ Munich, Dept Anesthesiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Cardiac Surg, D-81377 Munich, Germany
关键词
diagnostic techniques; cardiovascular; preload; fluid responsiveness; cardiac output; pulse contour analysis; mechanical ventilation;
D O I
10.1007/s00134-003-1649-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Real-time measurement of stroke volume variation by arterial pulse contour analysis (SVV) is useful in predicting volume responsiveness and monitoring volume therapy in mechanically ventilated patients. This study investigated the influence of the depth of tidal volume (V-t) on SVV both during the state of fluid responsiveness and after fluid loading in mechanically ventilated patients. Design and setting: Prospective study in a university hospital, adult cardiac surgery intensive care unit. Patients and participants: 20 hemodynamically stable patients immediately after cardiac surgery. Interventions: Stepwise fluid loading using colloids until stroke volume index (SVI) did not increase by more than 10%. Before and after fluid loading V-t was varied (5, 10, and 15 ml/kg body weight) in random order. Measurements and results: Pulse contour SVV was measured before and after volume loading at the respective V-t values. Thirteen patients responded to fluid loading with an increase in SVI greater than 10%, which confirmed volume responsiveness at baseline measurements. These were included in further analysis. During volume responsiveness SVV at V-t of 5 ml/kg (7+/-0.7%) and SVV at V-t of 15 ml/kg (21+/-2.5%) differed significantly from that at V-t of 10 ml/kg (15+/-2.1%). SVV was correlated significantly with the magnitude of V-t. After volume resuscitation SVV at the respective V-t was significantly reduced; further, SVV at V-t of 5 ml/kg(-1) (5.3+/-0.6%) and 15 ml/kg (16.2+/-2.0%) differed significantly from that at V-t of 10 ml/kg (10.2+/-1.0%). SVV and depth of V-t were significantly related. Conclusions: In addition to intravascular volume status SVV is affected by the depth of tidal volume under mechanical ventilation. This influence must be regarded when using SVV for functional preload monitoring.
引用
收藏
页码:476 / 480
页数:5
相关论文
共 50 条
  • [31] Influence of tidal volume on stroke volume variation. Does it really matter?
    Frédéric Michard
    Jean-Louis Teboul
    Christian Richard
    Intensive Care Medicine, 2003, 29 : 1613 - 1613
  • [32] Influence of tidal volume on stroke volume variation. Does it really matter?
    Michard, F
    Teboul, JL
    Richard, C
    INTENSIVE CARE MEDICINE, 2003, 29 (09) : 1613 - 1613
  • [33] The role of physicians' specialty in the initial setting of tidal volume in mechanically ventilated patients
    Oud, Lavi
    Mossbarger, Deborah
    Floyd, Molli
    Albin, Malia
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A224 - A224
  • [34] Tidal Volume Does Not Impact Outcomes in Mechanically Ventilated Patients with Neuromuscular Disease
    Vail, E. A.
    Restrepo, M. I.
    Anzueto, A.
    Penuelas, O.
    Thille, A.
    Rios, F.
    Raymondos, K.
    Gonzalez, M.
    Bin, D.
    Amin, P.
    Abroug, F.
    Esteban, A.
    Frutos-Vivar, F.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [35] Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of tidal volume
    Mouloudi, E
    Katsanoulas, K
    Anastasaki, M
    Hoing, S
    Georgopoulos, D
    INTENSIVE CARE MEDICINE, 1999, 25 (11) : 1215 - 1221
  • [36] Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of tidal volume
    E. Mouloudi
    K. Katsanoulas
    M. Anastasaki
    S. Hoing
    D. Georgopoulos
    Intensive Care Medicine, 1999, 25 : 1215 - 1221
  • [37] Exhaled tidal volume overestimation in mechanically ventilated patients with large cardiogenic oscillation
    Imanaka, H
    Takeuchi, M
    Tachibana, K
    Nishimura, M
    CRITICAL CARE MEDICINE, 2004, 32 (07) : 1546 - 1549
  • [38] The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children
    Lee, Ji Yeon
    Kim, Ji Young
    Choi, Chang Hyu
    Kim, Hong Soon
    Lee, Kyung Cheon
    Kwak, Hyun Jeong
    PEDIATRIC CARDIOLOGY, 2014, 35 (02) : 289 - 294
  • [39] The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children
    Ji Yeon Lee
    Ji Young Kim
    Chang Hyu Choi
    Hong Soon Kim
    Kyung Cheon Lee
    Hyun Jeong Kwak
    Pediatric Cardiology, 2014, 35 : 289 - 294
  • [40] INFLUENCE OF TIDAL VOLUME ON THE COMPLIANCE OF THE RESPIRATORY SYSTEM IN MECHANICALLY VENTILATED NEWBORN-INFANTS
    POPOW, C
    SIMBRUNER, G
    WIENER KLINISCHE WOCHENSCHRIFT, 1989, 101 (09) : 323 - 326