Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model

被引:26
|
作者
Kamei, Shuzo [1 ]
Osada, Denju [1 ]
Tamai, Kazuya [1 ]
Kato, Nakayuki [1 ]
Takai, Morimitsu [1 ]
Kameda, Masahiro [1 ]
Nohara, Yutaka [1 ]
机构
[1] Dokkyo Med Univ, Sch Med, Dept Orthopaed Surg, Mibu, Tochigi 3210293, Japan
关键词
FRAGMENT-SPECIFIC FIXATION; COMPRESSION PLATE; EXTERNAL FIXATION; DORSAL; SCREW;
D O I
10.1007/s00776-010-1466-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the present study was to compare the relative stability of five volar locking plates (all of which are available for the treatment of intraarticular fractures of the distal radius) under loading conditions simulating the physiological forces that occur during early active mobilization. Five plating techniques were applied to surgically simulated AO type C3.2 distal radius fractures in formalin-fixed cadavers. The specimens were tested with a servohydraulic materials testing machine with 250 N of axial compression load for 3000 cycles. After cyclic loading, the specimens were loaded until they demonstrated failure in axial compression. The five fixation systems studied included a DRV locking plate (group 1), a Stellar plate (group 2), an Acu-Loc plate (group 3), AO Locking Distal Radius System 2.4 (group 4); and a Matrix SmartLock plate (group 5). None of the plate fixations tested failed during the cyclic loading. Group 2 had a higher elastic limit than groups 4 and 5. There were no significant differences among the five groups for the failure load. Failure occurred at the distal portion of the fixation system, at the ulnar side locking pin, or the locking screw was bent (groups 1, 2, 3); the ulnar side locking screw was broken (groups 3, 4); the locking screw became loose (group 4); and the ulnar side locking screw was uncoupled from the screw hole (group 5). All of the five volar plate fixation systems provided sufficient stability to permit 3000 repeated motions of the digits after surgery for AO type C3 distal radius fractures.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 50 条
  • [21] Volar locking compression T-plate for distal radius fractures
    Lattmann, T
    Dietrich, M
    Meier, C
    Kilgus, M
    Platz, A
    BRITISH JOURNAL OF SURGERY, 2005, 92 (07) : 905 - 905
  • [22] Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation
    Satake, Hiroshi
    Hanaka, Naomi
    Honma, Ryusuke
    Watanabe, Tadayoshi
    Inoue, Shigeru
    Kanauchi, Yumiko
    Kato, Yoshihiro
    Nakajima, Taku
    Sato, Daisuke
    Eto, Jun
    Maruyama, Masahiro
    Naganuma, Yasushi
    Sasaki, Junya
    Toyono, Shuji
    Harada, Mikio
    Ishigaki, Daisuke
    Takahara, Masatoshi
    Takagi, Michiaki
    ORTHOPEDICS, 2016, 39 (05) : E893 - E896
  • [23] Combined Volar T-Plate and Dorsal Pi-Plate for Distal Radius Fractures: A Consecutive Series of 80 AO type C2 and C3 Cases
    Sagerfors, Marcus
    Bjorling, Patrik
    Niklasson, Johan
    Pettersson, Kurt
    JOURNAL OF WRIST SURGERY, 2019, 8 (03) : 180 - 185
  • [24] Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures
    Abe, Shingo
    Shimada, Toshiki
    Murase, Tsuyoshi
    Kuriyama, Kohji
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 389.e1 - 389.e13
  • [25] Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures
    Usta, Emirhan
    Akpolat, Ahmet O.
    Kahraman, Ahmet N.
    Kara, Adnan
    Oc, Yunus
    Kilinc, Bekir E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [26] Volar locking plate vs epibloc system for distal radius fractures in the elderly
    Solarino, Giuseppe
    Vicenti, Giovanni
    Abate, Antonella
    Carrozzo, Massimiliano
    Picca, Girolamo
    Colella, Antonio
    Moretti, Biagio
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S84 - S90
  • [27] Intraarticular Distal End Radius Fractures Treated with Volar Locking Plate Variations
    Gaonkar, Nishant
    Patil, Nitin
    Kolekar, Anupam
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1030 - S1032
  • [28] Volar Plate Fixation of AO Type C2 and C3 Distal Radius Fractures, A Single-Center Study of 55 Patients (vol 22, pg 467, 2008)
    Gruber, Gerald
    Gruber, Karl
    Giessauf, Christian
    Clar, Heimo
    Zacherl, Max
    Fuerst, Florentine
    Bernhardt, Gerwin A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (10) : 736 - 736
  • [29] Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture? a biomechanical study
    Kandemir, Utku
    Matityahu, Amir
    Desai, Rohan
    Puttlitz, Christian
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) : 605 - 610
  • [30] Volar Locking Plate Fixation for Distal Radius Fractures Distal to the Watershed Line with an Intact Lunate Volar Rim
    Cha, Soo Min
    Shin, Hyun Dae
    Kim, Seung Won
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (06): : 708 - 716