摘要
Objectives: The purpose of this study was to compare the fixation afforded by a dorsal nonlocking plate with a volar locking plate in a fracture model simulating an extra-articular distal radius fracture with dorsal comminution (OTA [Orthopaedic Trauma Association] type 23-A3.2). Methods: In 10 matched pairs of fresh-frozen cadaveric arms, a comminuted extra-articular dorsally unstable distal radius fracture (OTA type 23-A3.2) was created. The fractures were fixed with either dorsally placed nonlocking T-plate or volarly placed locking plate within matched pairs. The precycling stiffness with axial and torsional loading of the specimens was determined. The specimens were then loaded axially for 5000 cycles, and postcycling axial and torsional stiffness and load to failure were determined. Results: The mean axial and torsional stiffness before and after cyclic loading of fractures stabilized with dorsal nonlocking plate was not significantly different than fractures fixed with volar locking plate. Although the mean load to failure was greater for the volar locking plate group than dorsal nonlocking plate group, the difference was not significant. Conclusions: This study suggests that the fixation obtained with volar locking plates is as stable as fixation with a dorsal plate in acute healing period and can withstand the functional demands of the immediate postoperative period in dorsally comminuted unstable extra-articular distal radius fractures. Elimination of dorsal tendinopathy by using volar locking plates may lead to fewer long-term complications. Locking plates provided better stability in specimens with osteoporosis.
引用
收藏
页码:605 / 610
页数:6
相关论文
共 50 条
  • [1] Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: A biomechanical study
    Trease, C
    McIff, T
    Toby, EB
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 756 - 763
  • [2] Biomechanical Comparison of Locking versus Nonlocking Volar and Dorsal T-Plates for Fixation of Dorsally Comminuted Distal Radius Fractures
    Gondusky, Joseph S.
    Carney, Joseph
    Erpenbach, Jonathan
    Robertson, Claire
    Mahar, Andrew
    Oka, Richard
    Thompson, Michael
    Mazurek, Michael
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) : 44 - 50
  • [3] Internal fixation of dorsally comminuted fractures of the distal part of the radius: a biomechanical analysis of volar plate and intramedullary nail fracture stability
    Konstantinidis, Lukas
    Helwig, Peter
    Seifert, Judith
    Hirschmueller, Anja
    Liodakis, Emmanouil
    Suedkamp, Norbert Paul
    Oberst, Michael
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1529 - 1537
  • [4] Internal fixation of dorsally comminuted fractures of the distal part of the radius: a biomechanical analysis of volar plate and intramedullary nail fracture stability
    Lukas Konstantinidis
    Peter Helwig
    Judith Seifert
    Anja Hirschmüller
    Emmanouil Liodakis
    Norbert Paul Südkamp
    Michael Oberst
    Archives of Orthopaedic and Trauma Surgery, 2011, 131
  • [5] Internal fixation of dorsally displaced fractures of the distal part of the radius - A biomechanical analysis of volar plate fracture stability
    Willis, Andrew A.
    Kutsumi, Keiji
    Zobitz, Mark E.
    Cooney, William P., III
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (11): : 2411 - 2417
  • [6] Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation
    S. Erhart
    S. Toth
    P. Kaiser
    T. Kastenberger
    C. Deml
    R. Arora
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 879 - 885
  • [7] Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation
    Erhart, S.
    Toth, S.
    Kaiser, P.
    Kastenberger, T.
    Deml, C.
    Arora, R.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (06) : 879 - 885
  • [8] Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
    Blythe, Murray
    Stoffel, Karl
    Jarrett, Paul
    Kuster, Markus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10): : 1587 - 1593
  • [9] Dorsal and Volar 2.4-mm Locking Plate Fixation for AO Type C3 Dorsally Comminuted Distal Radius Fractures
    Chou, Ying-Chao
    Chen, Alvin Chao-Yu
    Chen, Chun-Ying
    Hsu, Yung-Heng
    Wu, Chi-Chuan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06): : 974 - 981
  • [10] Biomechanical Properties of 3-Dimensional Printed Volar Locking Distal Radius Plate: Comparison With Conventional Volar Locking Plate
    Kim, Sung-Jae
    Jo, Young-Hoon
    Choi, Wan-Sun
    Lee, Chang-Hun
    Lee, Bong-Gun
    Kim, Joo-Hak
    Lee, Kwang-Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 747.e1 - 747.e6