Generator-produced rubidium-82 positron emission tomography myocardial perfusion imaging-From basic aspects to clinical applications

被引:40
|
作者
Yoshinaga, Keiichiro [1 ]
Klein, Ran [2 ,3 ]
Tamaki, Nagara [2 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Mol Imaging, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido 0608638, Japan
[3] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Ottawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Generator; Myocardial blood flow; Positron emission tomography; Rubidium; CORONARY-ARTERY-DISEASE; BLOOD-FLOW; DIAGNOSTIC-ACCURACY; EXTERNAL DETECTORS; PROGNOSTIC VALUE; PET; QUANTIFICATION; HEART; DIPYRIDAMOLE; FRACTION;
D O I
10.1016/j.jjcc.2010.01.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiovascular disease is the leading cause of death in modern industrialized countries with an aging population. This fact has fueled the need for innovative diagnostic testing intended to improve coronary artery disease (CAD) patient care Detection of myocardial ischemia using myocardial perfusion imaging (MPI) plays an important role for CAD diagnosis and the prediction of future risk of cardiovascular events Positron emission tomography (PET) MPI has high diagnostic accuracy and can estimate regional myocardial blood flow (MBF) in patients with CAD. Rubidium-82 (Rb-82) is a generator-produced PET myocardial perfusion tracer and has been widely used in North America in clinical practice. Rb-82 PET has recently become available in some cardiovascular centers in Europe and Japan. Clinical trials are expected in both regions. Rb-82 PET has high diagnostic accuracy and recent data have shown its prognostic value. Thus, Rb-82 PET would greatly contribute to CAD patients' care. Rb-82 PET can also be used to quantify MBF. This review describes the current status of Rb-82 MPI from basic principles to clinical implications. This paper also highlights the recent development of MBF quantification using Rb-82 PET. (C) 2010 Japanese College of Cardiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 173
页数:11
相关论文
共 50 条
  • [41] Comparing Changes in Severe Versus Mild Perfusion Defect Size in Patients Who Underwent Serial Rubidium-82 Positron Emission Tomography Myocardial Perfusion Imaging
    Williams, Brent A.
    Merhige, Michael E.
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (10): : 1512 - 1517
  • [42] Incremental prognostic value of rubidium-82 myocardial perfusion positron emission tomography-computed tomography imaging in patients with known or suspected coronary artery disease
    Dorbala, Sharmila
    Hachamovitch, For
    Kwong, Raymond Y.
    Curillova, Zelmira
    Di Carli, Marcelo F.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 109A - 109A
  • [43] Incremental prognostic value of left ventricular ejection fraction assessment over myocardial perfusion imaging: A rubidium-82 positron emission tomography/computed tomography study
    Dorbala, Sharmila
    Hachamovitch, Rory
    Zelmira, Curillova
    Kwong, Raymond Y.
    Di Carli, Marcelo F.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 109A - 109A
  • [44] GA-68THM2BED - A POTENTIAL GENERATOR-PRODUCED TRACER OF MYOCARDIAL PERFUSION FOR POSITRON EMISSION TOMOGRAPHY
    MADSEN, SL
    WELCH, MJ
    MOTEKAITIS, RJ
    MARTELL, AE
    NUCLEAR MEDICINE AND BIOLOGY, 1992, 19 (04) : 431 - 444
  • [45] Pharmacologic stress/rest myocardial perfusion imaging with positron emission tomography and rubidium-82 on invasive procedure utilization, cost, and outcomes in coronary disease management
    Merhige, M
    Oliverio, J
    Shelton, V
    Watson, G
    Smith, K
    Frank, S
    Stern, G
    Avino, D
    Perna, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 310A - 310A
  • [46] Clinical performance of a prototype rubidium-82 elution system for PET myocardial perfusion imaging
    Renaud, Jennifer
    Guo, Ann
    Garrard, Linda
    Beanlands, Rob
    Dekemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [47] Assessment of a protocol for routine simultaneous myocardial blood flow measurement and standard myocardial perfusion imaging with rubidium-82 on a high count rate positron emission tomography system
    Tout, Deborah
    Tonge, Christine M.
    Muthu, Sivakumar
    Arumugam, Parthiban
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) : 1202 - 1211
  • [48] Impaired Myocardial Flow Reserve on Rubidium-82 Positron Emission Tomography Imaging Predicts Adverse Outcomes in Patients Assessed for Myocardial Ischemia
    Ziadi, Maria C.
    deKemp, Robert A.
    Williams, Kathryn A.
    Guo, Ann
    Chow, Benjamin J. W.
    Renaud, Jennifer M.
    Ruddy, Terrence D.
    Sarveswaran, Niroshi
    Tee, Rebecca E.
    Beanlands, Rob S. B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (07) : 740 - 748
  • [49] Rubidium-82 generator yield and efficiency for PET perfusion imaging: Comparison of two clinical systems
    Ali Ahmadi
    Ran Klein
    Howard C. Lewin
    Rob S. B. Beanlands
    Robert A. deKemp
    Journal of Nuclear Cardiology, 2020, 27 : 1728 - 1738
  • [50] Rubidium-82 generator yield and efficiency for PET perfusion imaging: Comparison of two clinical systems
    Ahmadi, Ali
    Klein, Ran
    Lewin, Howard C.
    Beanlands, Rob S. B.
    DeKemp, Robert A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) : 1728 - 1738