Generator-produced rubidium-82 positron emission tomography myocardial perfusion imaging-From basic aspects to clinical applications

被引:40
|
作者
Yoshinaga, Keiichiro [1 ]
Klein, Ran [2 ,3 ]
Tamaki, Nagara [2 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Mol Imaging, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido 0608638, Japan
[3] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Ottawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Generator; Myocardial blood flow; Positron emission tomography; Rubidium; CORONARY-ARTERY-DISEASE; BLOOD-FLOW; DIAGNOSTIC-ACCURACY; EXTERNAL DETECTORS; PROGNOSTIC VALUE; PET; QUANTIFICATION; HEART; DIPYRIDAMOLE; FRACTION;
D O I
10.1016/j.jjcc.2010.01.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiovascular disease is the leading cause of death in modern industrialized countries with an aging population. This fact has fueled the need for innovative diagnostic testing intended to improve coronary artery disease (CAD) patient care Detection of myocardial ischemia using myocardial perfusion imaging (MPI) plays an important role for CAD diagnosis and the prediction of future risk of cardiovascular events Positron emission tomography (PET) MPI has high diagnostic accuracy and can estimate regional myocardial blood flow (MBF) in patients with CAD. Rubidium-82 (Rb-82) is a generator-produced PET myocardial perfusion tracer and has been widely used in North America in clinical practice. Rb-82 PET has recently become available in some cardiovascular centers in Europe and Japan. Clinical trials are expected in both regions. Rb-82 PET has high diagnostic accuracy and recent data have shown its prognostic value. Thus, Rb-82 PET would greatly contribute to CAD patients' care. Rb-82 PET can also be used to quantify MBF. This review describes the current status of Rb-82 MPI from basic principles to clinical implications. This paper also highlights the recent development of MBF quantification using Rb-82 PET. (C) 2010 Japanese College of Cardiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 173
页数:11
相关论文
共 50 条
  • [31] Rubidium-82 Cardiac Positron Emission Tomography Imaging An Overview for the General Cardiologist
    Dhar, Ritesh
    Ananthasubramaniam, Karthikeyan
    CARDIOLOGY IN REVIEW, 2011, 19 (05) : 255 - 263
  • [32] Added prognostic value of myocardial blood flow quantitation in rubidium-82 positron emission tomography imaging
    Farhad, Hoshang
    Dunet, Vincent
    Bachelard, Kim
    Allenbach, Gilles
    Kaufmann, Philipp A.
    Prior, John O.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (12) : 1203 - 1210
  • [33] QUANTIFICATION OF REGIONAL MYOCARDIAL PERFUSION WITH GENERATOR-PRODUCED CU-62-PTSM AND POSITRON EMISSION TOMOGRAPHY
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    ANDERSON, CJ
    WELCH, MJ
    GREEN, MA
    BERGMANN, SR
    CIRCULATION, 1993, 87 (01) : 173 - 183
  • [34] What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography in obese patients with known or suspected CAD?
    Shah, Anuj R.
    Lertsburapa, Kirkeith
    Ahlberg, Alan
    Katten, Deborah
    Volker, Lyndy
    Cullom, S. James
    Bateman, Timothy
    Heller, Gary V.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A173 - A173
  • [35] ECONOMIC-ANALYSIS OF CLINICAL POSITRON EMISSION TOMOGRAPHY OF THE HEART WITH RUBIDIUM-82
    GOULD, KL
    GOLDSTEIN, RA
    MULLANI, NA
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (05) : 707 - 717
  • [36] Prognostic value of vasodilator response using rubidium-82 positron emission tomography myocardial perfusion imaging in patients with coronary artery disease
    Arasaratnam, Punitha
    Sadreddini, Masoud
    Yam, Yeung
    Kansal, Vinay
    Dorbala, Sharmila
    Di Carli, Marcelo F.
    Beanlands, Rob S.
    Merhige, Michael E.
    Williams, Brent A.
    Veledar, Emir
    Min, James K.
    Chen, Li
    Ruddy, Terrence D.
    Germano, Guido
    Berman, Daniel S.
    Shaw, Leslee J.
    Chow, Benjamin J. W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (04) : 538 - 548
  • [37] Prognostic value of vasodilator response using rubidium-82 positron emission tomography myocardial perfusion imaging in patients with coronary artery disease
    Punitha Arasaratnam
    Masoud Sadreddini
    Yeung Yam
    Vinay Kansal
    Sharmila Dorbala
    Marcelo F. Di Carli
    Rob S. Beanlands
    Michael E. Merhige
    Brent A. Williams
    Emir Veledar
    James K. Min
    Li Chen
    Terrence D. Ruddy
    Guido Germano
    Daniel S. Berman
    Leslee J. Shaw
    Benjamin J. W. Chow
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 538 - 548
  • [38] Prevalence and Correlates of Impaired Myocardial Blood Flow Reserve in Patients With Normal Myocardial Perfusion Rubidium-82 Positron Emission Tomography
    Rader, Valerie J.
    Courter, Staci A.
    Case, James A.
    Kennedy, Kevin F.
    Bateman, Timothy M.
    CIRCULATION, 2010, 122 (21)
  • [39] AN AUTOMATED MICRO-PROCESSOR CONTROLLED RUBIDIUM-82 GENERATOR FOR POSITRON EMISSION TOMOGRAPHY STUDIES
    YANO, Y
    BUDINGER, TF
    CAHOON, J
    HUESMAN, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 131 - NUCL
  • [40] Prognostic value of rubidium-82 perfusion positron emission tomography: Preliminary results from the consecutive 153 patients
    Yoshinaga, K
    Chow, B
    deKemp, R
    Williams, K
    Garrard, L
    Aung, M
    Mostert, K
    Gauthier, D
    Davies, RA
    Ruddy, T
    Beanlands, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 338A - 338A