Multivariate diagnosis analysis for chiller system for improving energy performance

被引:8
|
作者
Yu, F. W. [1 ]
Ho, W. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Hong Kong Community Coll, 8 Hung Lok Rd, Hong Kong, Hong Kong, Peoples R China
关键词
Coefficient of performance; Cooling tower; Operating status diagnosis; Survival analysis; Water-cooled chiller; STRATEGY; MODELS;
D O I
10.1016/j.jobe.2018.07.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating status of a large chiller system in buildings with central air-conditioning could vary at a given cooling demand and ambient condition. This study investigates the potential change of operating statuses and its influence on the system coefficient of performance (COP)-cooling energy output divided by the total electric power input. The system studied comprised four large and one small chillers. A set of primary chilled water pumps operated in different numbers to deliver the required flow rate of chilled water to the operating chillers. The actual flow rate to meet the building cooling demand was regulated by the secondary chilled water pumps. A set of evaporative cooling towers was installed to match the heat rejection required for the chillers. Comprehensive operating data were collected at 15-min intervals in 8 months. 18.46% of the total operating conditions were transitional statuses and unconventional operating statuses by switching on or off one extra cooling tower. This led to a 33.9-64.9% drop in individual system COPs. An examination of the variation of system load ratios and ambient wet bulb temperatures showed that the system COP was higher at the pair-up operation of system components even at higher wet bulb temperatures. A survival analysis indicated that the transitional statuses depended mainly on the temperature of chilled water returning to the evaporators and the temperatures of cooling water entering and leaving the condensers. Minimizing unnecessary transitional statuses and restoring the pair-up operation of system components could save electricity by 2.72%.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 50 条
  • [31] Improving building energy system performance by continuous commissioning
    Liu, MS
    Claridge, DE
    Haberl, JS
    Turner, WD
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 1606 - 1612
  • [32] THEORETICAL STUDY AND PERFORMANCE ANALYSIS OF AN ADSORPTION CHILLER
    Popa, V
    Costiuc, L.
    Cuzic, M.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 1123 - +
  • [33] Improving building energy system performance by continuous commissioning
    Liu, MS
    ENERGY ENGINEERING, 1999, 96 (05) : 46 - 57
  • [34] Faults diagnosis in a photovoltaic system based on multivariate statistical analysis
    Gnetchejo, Patrick Juvet
    Essiane, Salome Ndjakomo
    Ele, Pierre
    Dadje, Abdouramani
    Chen, Zhicong
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021, 47 (01) : 7383 - 7404
  • [35] Application of Data Fusion and FDD for Improving the Performance of Chiller Sequencing Control
    Wang, Shengwei
    Sun, Yongjun
    Huang, Gongsheng
    Xiao, Fu
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 2000 - 2007
  • [36] Improving the PCA-based Chiller Sensor Fault Diagnosis with Relative Contribution
    Hu, Yunpeng
    Gan, Zhibang
    2024 5TH INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND APPLICATION, ICCEA 2024, 2024, : 1439 - 1442
  • [37] Evaluations of energy performance for greenhouses based on multivariate analysis methodology
    Olofsson, Thomas
    Majabacka, Andreas
    Engblom, Sten
    PROCEEDINGS OF THE IIIRD INTERNATIONAL SYMPOSIUM ON MODELS FOR PLANT GROWTH, ENVIRONMENTAL CONTROL AND FARM MANAGEMENT IN PROTECTED CULTIVATION, 2006, (718): : 211 - +
  • [38] Performance Analysis of Brine Chiller Refrigeration Cycles
    Yoon, Jung-In
    Son, Chang-Hyo
    Choi, Kwang-Hwan
    Kim, Young-Bok
    Jung, Suk-Ho
    Moon, Changuk
    AETA 2016: RECENT ADVANCES IN ELECTRICAL ENGINEERING AND RELATED SCIENCES: THEORY AND APPLICATION, 2017, 415 : 184 - 194
  • [39] Using annual building energy analysis for the sizing of cooling tower for optimal chiller-cooling energy performance
    Liu, Chia-Wei
    Chuah, Yew-Khoy
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 43 - 49
  • [40] Comparative Performance Analysis of Induction and Synchronous Reluctance Motors in Chiller Systems for Energy Efficient Buildings
    Oliveira, Felipe
    Ukil, Abhisek
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (08) : 4384 - 4393