Multivariate diagnosis analysis for chiller system for improving energy performance

被引:8
|
作者
Yu, F. W. [1 ]
Ho, W. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Hong Kong Community Coll, 8 Hung Lok Rd, Hong Kong, Hong Kong, Peoples R China
关键词
Coefficient of performance; Cooling tower; Operating status diagnosis; Survival analysis; Water-cooled chiller; STRATEGY; MODELS;
D O I
10.1016/j.jobe.2018.07.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating status of a large chiller system in buildings with central air-conditioning could vary at a given cooling demand and ambient condition. This study investigates the potential change of operating statuses and its influence on the system coefficient of performance (COP)-cooling energy output divided by the total electric power input. The system studied comprised four large and one small chillers. A set of primary chilled water pumps operated in different numbers to deliver the required flow rate of chilled water to the operating chillers. The actual flow rate to meet the building cooling demand was regulated by the secondary chilled water pumps. A set of evaporative cooling towers was installed to match the heat rejection required for the chillers. Comprehensive operating data were collected at 15-min intervals in 8 months. 18.46% of the total operating conditions were transitional statuses and unconventional operating statuses by switching on or off one extra cooling tower. This led to a 33.9-64.9% drop in individual system COPs. An examination of the variation of system load ratios and ambient wet bulb temperatures showed that the system COP was higher at the pair-up operation of system components even at higher wet bulb temperatures. A survival analysis indicated that the transitional statuses depended mainly on the temperature of chilled water returning to the evaporators and the temperatures of cooling water entering and leaving the condensers. Minimizing unnecessary transitional statuses and restoring the pair-up operation of system components could save electricity by 2.72%.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 50 条
  • [21] Analyzing Refrigerant Contaminants and Reclamation Service to Prolong Chiller Lifespan and Improving Chiller Energy Efficiency
    Zhang, Hanwen
    Ukil, Abhisek
    Li, Yingliang
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 7085 - 7090
  • [22] Improved energy management of chiller systems by multivariate and data envelopment analyses
    Yu, F. W.
    Chan, K. T.
    APPLIED ENERGY, 2012, 92 : 168 - 174
  • [23] Performance analysis of control valves for a novel adsorption chiller with thermal energy storage
    Clausel, Tagne Takote Brice
    Anyanwu, Cosmas
    Eke, Mkpamdi
    Mokom, Charity
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 69
  • [24] Energy and exergy analysis with environment benefit of the underground cooling system of the chiller plant
    Al-qazzaz, Ameer Hussein Shakir
    Farzaneh-Gord, Mahmood
    Niazmand, Hamid
    RESULTS IN ENGINEERING, 2024, 22
  • [25] Energy and exergy analysis with environment benefit of the underground cooling system of the chiller plant
    Al-qazzaz, Ameer Hussein Shakir
    Farzaneh-Gord, Mahmood
    Niazmand, Hamid
    Results in Engineering, 2024, 22
  • [26] Determinants of low energy performance in a multi-chiller system serving an educational premise
    Ho, W. T.
    Yu, F. W.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 114 : 47 - 53
  • [27] Measurement and verification of energy performance for chiller system retrofit with k nearest neighbour regression
    Ho, W. T.
    Yu, F. W.
    JOURNAL OF BUILDING ENGINEERING, 2022, 46
  • [28] An Effective Fault Detection and Diagnosis Approach for Chiller System
    Li, Zhi
    Yuan, Baolong
    Li, Yupeng
    Sun, Liangliang
    Jia, Haiqi
    Qi, Yuanwei
    Sun, Yuchen
    IFAC PAPERSONLINE, 2019, 52 (10): : 55 - 60
  • [29] Performance analysis of univariate and multivariate EEG measurements in the diagnosis of ADHD
    Gonzalez, Julian J.
    Mendez, Leopoldo D.
    Manas, Soledad
    Rosario Duque, Ma
    Pereda, Ernesto
    De Vera, Luis
    CLINICAL NEUROPHYSIOLOGY, 2013, 124 (06) : 1139 - 1150
  • [30] AN ANALYSIS OF CHILLER ENERGY SAVINGS USING AN ADAPTIVE NEURO-FUZZY INFERENCE SYSTEM
    Chan, Tien-Shun
    Chang, Yung-Chung
    Lu, Jyun-Ting
    ENERGY AND MECHANICAL ENGINEERING, 2016, : 344 - 357