Multivariate diagnosis analysis for chiller system for improving energy performance

被引:8
|
作者
Yu, F. W. [1 ]
Ho, W. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Hong Kong Community Coll, 8 Hung Lok Rd, Hong Kong, Hong Kong, Peoples R China
关键词
Coefficient of performance; Cooling tower; Operating status diagnosis; Survival analysis; Water-cooled chiller; STRATEGY; MODELS;
D O I
10.1016/j.jobe.2018.07.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating status of a large chiller system in buildings with central air-conditioning could vary at a given cooling demand and ambient condition. This study investigates the potential change of operating statuses and its influence on the system coefficient of performance (COP)-cooling energy output divided by the total electric power input. The system studied comprised four large and one small chillers. A set of primary chilled water pumps operated in different numbers to deliver the required flow rate of chilled water to the operating chillers. The actual flow rate to meet the building cooling demand was regulated by the secondary chilled water pumps. A set of evaporative cooling towers was installed to match the heat rejection required for the chillers. Comprehensive operating data were collected at 15-min intervals in 8 months. 18.46% of the total operating conditions were transitional statuses and unconventional operating statuses by switching on or off one extra cooling tower. This led to a 33.9-64.9% drop in individual system COPs. An examination of the variation of system load ratios and ambient wet bulb temperatures showed that the system COP was higher at the pair-up operation of system components even at higher wet bulb temperatures. A survival analysis indicated that the transitional statuses depended mainly on the temperature of chilled water returning to the evaporators and the temperatures of cooling water entering and leaving the condensers. Minimizing unnecessary transitional statuses and restoring the pair-up operation of system components could save electricity by 2.72%.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 50 条
  • [1] Comparative study on the energy performance of chiller system in an institutional building with stochastic frontier analysis
    Yu, F. W.
    Chan, K. T.
    Yang, J.
    Sit, R. K. Y.
    ENERGY AND BUILDINGS, 2015, 89 : 206 - 212
  • [2] Analysis of chiller system performance with different component combinations
    Yu, F. W.
    Ho, W. T.
    APPLIED THERMAL ENGINEERING, 2019, 154 : 699 - 710
  • [3] Chiller system performance benchmark by data envelopment analysis
    Yu, F. W.
    Chan, K. T.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (07): : 1815 - 1823
  • [4] Chiller system performance management with market basket analysis
    Ho, Wai Tung
    Yu, Fu Wing
    FACILITIES, 2021, 39 (9-10) : 667 - 687
  • [5] EXPERIMENTAL DESIGN AND REGRESSION ANALYSIS FOR PERFORMANCE OF A CHILLER SYSTEM
    Ekren, Orhan
    Ekren, Banu Y.
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2011, 31 (01) : 59 - 65
  • [6] In-situ diagnosis of vapor-compressed chiller performance for energy saving
    Shin, Y
    Kim, Y
    Moon, GW
    Choi, SW
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2005, 19 (08) : 1670 - 1681
  • [7] Improving the Performance of Steam Turbine Chiller Plants
    Copeland, Charles C.
    ASHRAE JOURNAL, 2019, 61 (08) : 20 - 28
  • [8] In-situ diagnosis of vapor-compressed chiller performance for energy saving
    Younggy Shin
    Youngil Kim
    Guee-Won Moon
    Seok-Weon Choi
    Journal of Mechanical Science and Technology, 2005, 19 : 1670 - 1681
  • [9] Improving the Performance of Steam Turbine Chiller Plants
    Abedin, Ainul
    ASHRAE JOURNAL, 2019, 61 (09) : 10 - 11
  • [10] COOLING EFFECTIVENESS OF MIST PRECOOLER FOR IMPROVING ENERGY PERFORMANCE OF AIR-COOLED CHILLER
    Yu, Fu Wing
    Chan, Kwok Tai
    Yang, Jia
    Sit, Rachel Kam Yung
    THERMAL SCIENCE, 2018, 22 (01): : 193 - 204