Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization

被引:8
|
作者
Gay, H. A. [1 ]
Allison, R. R.
Downie, G. H.
Mota, H. C.
Austerlitz, C.
Jenkins, T.
Sibata, C. H.
机构
[1] E Carolina Univ, Brody Sch Med, Dept Radiat Oncol, Greenville, NC 27858 USA
[2] E Carolina Univ, Brody Sch Med, Dept Internal Med, Pulm & Crit Care Med Sect, Greenville, NC 27858 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 11期
关键词
D O I
10.1088/0031-9155/52/11/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A number of patients with lung cancer receive either palliative or curative high-dose-rate (HDR) endobronchial brachytherapy. Up to a third of patients treated with endobronchial HDR die from hemoptysis. Rather than accept hemoptysis as an expected potential consequence of HDR, we have calculated the radial dose distribution for an Ir-192 HDR source, rigorously examined the dose and prescription points recommended by the American Brachytherapy Society (ABS), and performed a radiobiological-based analysis. The radial dose rate of a commercially available Ir-192 source was calculated with a Monte Carlo simulation. Based on the linear quadratic model, the estimated palliative, curative and blood vessel rupture radii from the center of an Ir-192 source were obtained for the ABS recommendations and a series of customized HDR prescriptions. The estimated radius at risk for blood vessel perforation for the ABS recommendations ranges from 7 to 9 mm. An optimized prescription may in some situations reduce this radius to 4 mm. The estimated blood perforation radius is generally smaller than the palliative radius. Optimized and individualized endobronchial HDR prescriptions are currently feasible based on our current understanding of tumor and normal tissue radiobiology. Individualized prescriptions could minimize complications such as fatal hemoptysis without sacrificing efficacy. Fiducial stents, HDR catheter centering or spacers and the use of CT imaging to better assess the relationship between the catheter and blood vessels promise to be useful strategies for increasing the therapeutic index of this treatment modality. Prospective trials employing treatment optimization algorithms are needed.
引用
收藏
页码:2987 / 2999
页数:13
相关论文
共 50 条
  • [41] High-dose-rate endobronchial brachytherapy in endobronchial metastatic malignant chondroid syringoma
    Solomonov, A
    Rosenblatt, E
    Ben-Izhak, O
    Goralnik, L
    Yigla, M
    RESPIRATION, 2001, 68 (04) : 406 - 410
  • [42] TEMPORARY ENDOBRONCHIAL BRACHYTHERAPY OF BRONCHOGENIC-CARCINOMA WITH IR-192 HIGH-DOSE AND NEODYM YAG LASER IN COMBINATION
    MACHA, HN
    MAI, J
    KOCH, K
    SCHUMACHER, W
    KRUMHAAR, D
    LODDENKEMPER, R
    EUROPEAN JOURNAL OF RESPIRATORY DISEASES, 1986, 69 : A96 - A96
  • [43] TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy
    Kirov, AS
    Williamson, JF
    Meigooni, AS
    Zhu, Y
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12): : 2015 - 2036
  • [44] Quantitative Evaluation of Dosimetric Accuracy of a Multiple-Diode-Array Detector (MapCHECK2) for High-Dose-Rate Ir-192 Brachytherapy
    Taguenang, J.
    Herman, T. De La Fuente
    Young, J.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [45] Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)
    Harpool, K.
    Herman, T. De La Fuente
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2016, 43 (06) : 3626 - 3627
  • [46] The effect of rib and lung heterogeneities on the computed dose to lung in Ir-192 High-Dose-Rate breast brachytherapy: Monte Carlo versus a treatment planning system
    Yazdi, Hossein Salehi
    Shamsaei, Mojtaba
    Jaberi, Ramin
    Shabani, Hamid Reza
    Allahverdi, Mahmoud
    Vaezzadeh, Seyed Ali
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (03) : 394 - 398
  • [47] DOSE-RATE INTRALUMINAL BRACHYTHERAPY FOR TREATMENT OF ESOPHAGEAL CANCER WITH IR-192 WIRES
    CASPERS, RJL
    DAVELAAR, J
    SEWSINGH, EN
    GRIFFIOEN, G
    LEER, JWH
    BRACHYTHERAPY 2, 1989, : 445 - 448
  • [48] Clinical application of 192Ir High-Dose-Rate brachytherapy in metastatic lymph nodes of the neck
    Lu, Hongling
    Sun, Yunchuan
    Gao, Yan
    Xiao, Li
    Zhou, Jianxi
    Yin, Xiaoming
    Guo, Wei
    Fan, Kui
    DISCOVER ONCOLOGY, 2023, 14 (01)
  • [49] Heterogeneity and scatter effects on Ir-192 brachytherapy dose distribution
    Osman, Alexander F. I.
    Maalej, Nabil
    Ul-Rahman, Khateeb
    Rahman, Wamied Abdel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1210 - 1215
  • [50] Clinical application of 192Ir High-Dose-Rate brachytherapy in metastatic lymph nodes of the neck
    Hongling Lu
    Yunchuan Sun
    Yan Gao
    Li Xiao
    Jianxi Zhou
    Xiaoming Yin
    Wei Guo
    Kui Fan
    Discover Oncology, 14